Coronary artery calcium quantification at multi-detector row helical CT versus electron-beam CT

被引:76
作者
Stanford, W
Thompson, BH
Burns, TL
Heery, SD
Burr, MC
机构
[1] Univ Iowa, Coll Med, Dept Radiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Coll Publ Hlth, Dept Biostat, Iowa City, IA 52242 USA
关键词
computed tomography (CT); comparative studies; electron beam; helical; multi-detector row; coronary vessels; calcification;
D O I
10.1148/radiol.2302020901
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare coronary artery calcium scores from a multi-detector row helical computed tomographic (CT) scanner with those from an electron-beam CT scanner; with emphasis on subjects with calcium scores less than 400. MATERIALS AND METHODS: Seventy-eight asymptomatic subjects (37 women, 41 men; age range, 39-78 years; mean age, 54.2 years) underwent multi-detector row CT and electron-beam CT. Volume and Agatston scores were calculated with a workstation. Statistical analyses included assessment of association between calcium scores from two scanners, calculation of percent absolute difference to assess score variability between scanners, equivalence analysis, construction of Bland-Altman plots to assess agreement between scores, and assessment of changes in score grouping and risk criteria based on score differences between scanners. RESULTS: Electron-beam CT calcium scores were higher than multi-detector row CT scores. Linear association between calcium scores obtained from paired scans was significant (r = 0.96-0.99, P < .001). Mean percent absolute differences were 67.9% and 65.0% for volume and Agatston scores, respectively (48.6% and 46.3% for corresponding natural log-transformed scores). In subjects with a score of 11 or greater, mean percent absolute differences between electron-beam CT and multidetector row CT scores ranged from 15% to 30% (<10% for natural log-transformed calcium scores). With a 20% equivalence limit, calcium scores from the two scanners were statistically equivalent (P <.05). Score grouping would have been subject to change in 12 (11 increased and one decreased; six with scores of 11 or greater); and possible risk management decisions would have been subject to change in eight (16%) of 51 subjects who underwent electron-beam CT versus multi-detector row CT scanning. CONCLUSION: Multi-detector row CT appears to be comparable to electron-beam CT for coronary calcification screening, except in subjects with a calcium score less than 11. ((C))RSNA, 2004.
引用
收藏
页码:397 / 402
页数:6
相关论文
共 50 条
  • [41] Multi-detector row CT angiography of the brain at various kilovoltage settings
    Ertl-Wagner, BB
    Hoffmann, RT
    Bruning, R
    Herrmann, K
    Snyder, B
    Blume, JD
    Reiser, MF
    RADIOLOGY, 2004, 231 (02) : 528 - 535
  • [42] Assessment of coronary artery stent patency by electron-beam CT
    Knollmann, FD
    Möller, J
    Gebert, A
    Bethge, C
    Felix, R
    EUROPEAN RADIOLOGY, 2004, 14 (08) : 1341 - 1347
  • [43] Assessment of coronary artery stent patency by electron-beam CT
    Friedrich D. Knollmann
    Jörg Möller
    Axel Gebert
    Christian Bethge
    Roland Felix
    European Radiology, 2004, 14 : 1341 - 1347
  • [44] Hepatocellular carcinoma: Detection with triple-phase multi-detector row helical CT in patients with chronic hepatitis
    Laghi, A
    Iannaccone, R
    Rossi, P
    Carbone, I
    Ferrari, R
    Mangiapane, F
    Nofroni, I
    Passariello, R
    RADIOLOGY, 2003, 226 (02) : 543 - 549
  • [45] CT colonography: Protocol optimization with multi-detector row CT - Study in an anthropomorphic colon phantom
    Wessling, J
    Fischbach, R
    Meier, N
    Allkemper, T
    Klusmeier, J
    Ludwig, K
    Heindel, W
    RADIOLOGY, 2003, 228 (03) : 753 - 759
  • [46] Single versus multi-detector row CT: Comparison of radiation doses and dose profiles
    Thornton, FJ
    Paulson, EK
    Yoshizumi, TT
    Frush, DP
    Nelson, RC
    ACADEMIC RADIOLOGY, 2003, 10 (04) : 379 - 385
  • [47] CORONARY-ARTERY DISEASE - PREDICTION WITH IN-VITRO ELECTRON-BEAM CT
    MAUTNER, SL
    MAUTNER, GC
    FROEHLICH, J
    FEUERSTEIN, IM
    PROSCHAN, MA
    ROBERTS, WC
    DOPPMAN, JL
    RADIOLOGY, 1994, 192 (03) : 625 - 630
  • [48] Multi-detector row CT of mesenteric ischemia: Can it be done?
    Horton, KM
    Fishman, EK
    RADIOGRAPHICS, 2001, 21 (06) : 1463 - 1473
  • [49] Coronary artery bypass grafts: ECG-gated multi-detector row CT angiography-influence of image reconstruction interval on graft visibility
    Willmann, JK
    Weishaupt, D
    Kobza, R
    Verdun, FR
    Seifert, B
    Marincek, B
    Boehm, T
    RADIOLOGY, 2004, 232 (02) : 568 - 577
  • [50] Coronary artery calcification measured at electron-beam CT: Agreement in dual scan runs and change over time
    Bielak, LF
    Sheedy, PF
    Peyser, PA
    RADIOLOGY, 2001, 218 (01) : 224 - 229