Coronary artery calcium quantification at multi-detector row helical CT versus electron-beam CT

被引:76
|
作者
Stanford, W
Thompson, BH
Burns, TL
Heery, SD
Burr, MC
机构
[1] Univ Iowa, Coll Med, Dept Radiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Coll Publ Hlth, Dept Biostat, Iowa City, IA 52242 USA
关键词
computed tomography (CT); comparative studies; electron beam; helical; multi-detector row; coronary vessels; calcification;
D O I
10.1148/radiol.2302020901
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare coronary artery calcium scores from a multi-detector row helical computed tomographic (CT) scanner with those from an electron-beam CT scanner; with emphasis on subjects with calcium scores less than 400. MATERIALS AND METHODS: Seventy-eight asymptomatic subjects (37 women, 41 men; age range, 39-78 years; mean age, 54.2 years) underwent multi-detector row CT and electron-beam CT. Volume and Agatston scores were calculated with a workstation. Statistical analyses included assessment of association between calcium scores from two scanners, calculation of percent absolute difference to assess score variability between scanners, equivalence analysis, construction of Bland-Altman plots to assess agreement between scores, and assessment of changes in score grouping and risk criteria based on score differences between scanners. RESULTS: Electron-beam CT calcium scores were higher than multi-detector row CT scores. Linear association between calcium scores obtained from paired scans was significant (r = 0.96-0.99, P < .001). Mean percent absolute differences were 67.9% and 65.0% for volume and Agatston scores, respectively (48.6% and 46.3% for corresponding natural log-transformed scores). In subjects with a score of 11 or greater, mean percent absolute differences between electron-beam CT and multidetector row CT scores ranged from 15% to 30% (<10% for natural log-transformed calcium scores). With a 20% equivalence limit, calcium scores from the two scanners were statistically equivalent (P <.05). Score grouping would have been subject to change in 12 (11 increased and one decreased; six with scores of 11 or greater); and possible risk management decisions would have been subject to change in eight (16%) of 51 subjects who underwent electron-beam CT versus multi-detector row CT scanning. CONCLUSION: Multi-detector row CT appears to be comparable to electron-beam CT for coronary calcification screening, except in subjects with a calcium score less than 11. ((C))RSNA, 2004.
引用
收藏
页码:397 / 402
页数:6
相关论文
共 50 条
  • [31] Multi-detector row CT angiography in patients with abdominal angina
    Cademartiri, F
    Raaijmakers, RHJM
    Kuiper, JW
    van Dijk, LC
    Pattynama, PMT
    Krestin, GP
    RADIOGRAPHICS, 2004, 24 (04) : 969 - 984
  • [32] Pancreatic carcinoma: Developing a protocol for multi-detector row CT
    Johnson, CD
    RADIOLOGY, 2001, 220 (01) : 3 - 4
  • [33] Coronary artery stenoses: Assessment with contrast-enhanced electron-beam CT and axial reconstructions
    Reddy, GP
    Chernoff, DM
    Adams, JR
    Higgins, CB
    RADIOLOGY, 1998, 208 (01) : 167 - 172
  • [34] Quantification and characterization of carotid calcium with multi-detector CT-angiography
    Miralles, M.
    Merino, J.
    Busto, M.
    Perich, X.
    Barranco, C.
    Vidal-Barraquer, F.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2006, 32 (05) : 561 - 567
  • [35] Laparoscopic splenectomy: Multi-detector row CT for preoperative evaluation
    Napoli, A
    Catalano, C
    Silecchia, G
    Fabiano, P
    Fraioli, F
    Pediconi, F
    Venditti, F
    Basso, N
    Passariello, R
    RADIOLOGY, 2004, 232 (02) : 361 - 367
  • [36] Hereditary hemorrhagic telangiectasia:: Multi-detector row helical CT assessment of hepatic involvement
    Ianora, AAS
    Memeo, M
    Sabbà, C
    Cirulli, A
    Rotondo, A
    Angelelli, G
    RADIOLOGY, 2004, 230 (01) : 250 - 259
  • [37] Suspected acute pulmonary embolism: Evaluation with multi-detector row CT versus digital subtraction pulmonary arteriography
    Winer-Muram, HT
    Rydberg, J
    Johnson, MS
    Tarver, RD
    Williams, MD
    Shah, H
    Namyslowski, J
    Conces, D
    Jennings, SG
    Ying, J
    Trerotola, SO
    Kopecky, KK
    RADIOLOGY, 2004, 233 (03) : 806 - 815
  • [38] Coronary artery calcium score:: Influence of reconstruction interval at 16-detector row CT with retrospective electrocardiographic gating
    Schlosser, T
    Hunold, P
    Schmermund, A
    Kühl, H
    Waltering, KU
    Debatin, JF
    Barkhausen, J
    RADIOLOGY, 2004, 233 (02) : 586 - 589
  • [39] Spatial variation of resolution and noise in multi-detector row spiral CT
    Meinel, JF
    Wang, G
    Jiang, M
    Frei, T
    Vannier, M
    Hoffman, E
    ACADEMIC RADIOLOGY, 2003, 10 (06) : 607 - 613
  • [40] Isoattenuating pancreatic adenocarcinoma at multi-detector row CT: Secondary signs
    Prokesch, RW
    Chow, LC
    Beaulieu, CF
    Bammer, R
    Jeffrey, RB
    RADIOLOGY, 2002, 224 (03) : 764 - 768