Coronary artery calcium quantification at multi-detector row helical CT versus electron-beam CT

被引:76
|
作者
Stanford, W
Thompson, BH
Burns, TL
Heery, SD
Burr, MC
机构
[1] Univ Iowa, Coll Med, Dept Radiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Coll Publ Hlth, Dept Biostat, Iowa City, IA 52242 USA
关键词
computed tomography (CT); comparative studies; electron beam; helical; multi-detector row; coronary vessels; calcification;
D O I
10.1148/radiol.2302020901
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare coronary artery calcium scores from a multi-detector row helical computed tomographic (CT) scanner with those from an electron-beam CT scanner; with emphasis on subjects with calcium scores less than 400. MATERIALS AND METHODS: Seventy-eight asymptomatic subjects (37 women, 41 men; age range, 39-78 years; mean age, 54.2 years) underwent multi-detector row CT and electron-beam CT. Volume and Agatston scores were calculated with a workstation. Statistical analyses included assessment of association between calcium scores from two scanners, calculation of percent absolute difference to assess score variability between scanners, equivalence analysis, construction of Bland-Altman plots to assess agreement between scores, and assessment of changes in score grouping and risk criteria based on score differences between scanners. RESULTS: Electron-beam CT calcium scores were higher than multi-detector row CT scores. Linear association between calcium scores obtained from paired scans was significant (r = 0.96-0.99, P < .001). Mean percent absolute differences were 67.9% and 65.0% for volume and Agatston scores, respectively (48.6% and 46.3% for corresponding natural log-transformed scores). In subjects with a score of 11 or greater, mean percent absolute differences between electron-beam CT and multidetector row CT scores ranged from 15% to 30% (<10% for natural log-transformed calcium scores). With a 20% equivalence limit, calcium scores from the two scanners were statistically equivalent (P <.05). Score grouping would have been subject to change in 12 (11 increased and one decreased; six with scores of 11 or greater); and possible risk management decisions would have been subject to change in eight (16%) of 51 subjects who underwent electron-beam CT versus multi-detector row CT scanning. CONCLUSION: Multi-detector row CT appears to be comparable to electron-beam CT for coronary calcification screening, except in subjects with a calcium score less than 11. ((C))RSNA, 2004.
引用
收藏
页码:397 / 402
页数:6
相关论文
共 50 条
  • [21] Single- versus multi-detector row CT of the brain: Quality assessment
    Jones, TR
    Kaplan, RT
    Lane, B
    Atlas, SW
    Rubin, GD
    RADIOLOGY, 2001, 219 (03) : 750 - 755
  • [22] Multi-detector row CT urography in the evaluation of hematuria
    Joffe, SA
    Servaes, S
    Okon, S
    Horowitz, M
    RADIOGRAPHICS, 2003, 23 (06) : 1441 - 1455
  • [23] Multi-detector row CT: Radiation dose characteristics
    Hamberg, LM
    Rhea, JT
    Hunter, GJ
    Thrall, JH
    RADIOLOGY, 2003, 226 (03) : 762 - 772
  • [24] Current concepts in multi-detector row CT evaluation of the coronary arteries: Principles, techniques, and anatomy
    Pannu, HK
    Flohr, TG
    Corl, FM
    Fishman, EK
    RADIOGRAPHICS, 2003, 23 : S111 - S125
  • [25] Multi-detector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    Raptopoulos, V
    Boiselle, PM
    RADIOLOGY, 2001, 221 (03) : 606 - 613
  • [26] Aortic atherosclerosis detected with electron-beam CT as a predictor of obstructive coronary artery disease
    Takasu, J
    Mao, S
    Budoff, MJ
    ACADEMIC RADIOLOGY, 2003, 10 (06) : 631 - 637
  • [27] Hypervascular hepatocellular carcinoma: Detection with double arterial phase multi-detector row helical CT
    Murakami, T
    Kim, T
    Takamura, M
    Hori, M
    Takahashi, S
    Federle, MP
    Tsuda, K
    Osuga, K
    Kawata, S
    Nakamura, H
    Kudo, M
    RADIOLOGY, 2001, 218 (03) : 763 - 767
  • [28] Optimization of eight-element multi-detector row helical CT technology for evaluation of the abdomen
    Gupta, AK
    Nelson, RC
    Johnson, GA
    Paulson, EK
    Delong, DM
    Yoshizumi, TT
    RADIOLOGY, 2003, 227 (03) : 739 - 745
  • [29] Pulmonary embolism: Optimization of small pulmonary artery visualization at multi-detector row CT
    Patel, S
    Kazerooni, EA
    Cascade, PN
    RADIOLOGY, 2003, 227 (02) : 455 - 460
  • [30] Multi-detector row CT: Principles and practice for abdominal applications
    Saini, S
    RADIOLOGY, 2004, 233 (02) : 323 - 327