PURPOSE: To compare coronary artery calcium scores from a multi-detector row helical computed tomographic (CT) scanner with those from an electron-beam CT scanner; with emphasis on subjects with calcium scores less than 400. MATERIALS AND METHODS: Seventy-eight asymptomatic subjects (37 women, 41 men; age range, 39-78 years; mean age, 54.2 years) underwent multi-detector row CT and electron-beam CT. Volume and Agatston scores were calculated with a workstation. Statistical analyses included assessment of association between calcium scores from two scanners, calculation of percent absolute difference to assess score variability between scanners, equivalence analysis, construction of Bland-Altman plots to assess agreement between scores, and assessment of changes in score grouping and risk criteria based on score differences between scanners. RESULTS: Electron-beam CT calcium scores were higher than multi-detector row CT scores. Linear association between calcium scores obtained from paired scans was significant (r = 0.96-0.99, P < .001). Mean percent absolute differences were 67.9% and 65.0% for volume and Agatston scores, respectively (48.6% and 46.3% for corresponding natural log-transformed scores). In subjects with a score of 11 or greater, mean percent absolute differences between electron-beam CT and multidetector row CT scores ranged from 15% to 30% (<10% for natural log-transformed calcium scores). With a 20% equivalence limit, calcium scores from the two scanners were statistically equivalent (P <.05). Score grouping would have been subject to change in 12 (11 increased and one decreased; six with scores of 11 or greater); and possible risk management decisions would have been subject to change in eight (16%) of 51 subjects who underwent electron-beam CT versus multi-detector row CT scanning. CONCLUSION: Multi-detector row CT appears to be comparable to electron-beam CT for coronary calcification screening, except in subjects with a calcium score less than 11. ((C))RSNA, 2004.
引用
收藏
页码:397 / 402
页数:6
相关论文
共 50 条
  • [1] Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT
    Kopp, AF
    Ohnesorge, B
    Becker, C
    Schröder, S
    Heuschmid, M
    Küttner, A
    Kuzo, R
    Claussen, CD
    RADIOLOGY, 2002, 225 (01) : 113 - 119
  • [2] Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT
    Hunold, P
    Vogt, FM
    Schmermund, A
    Debatin, JF
    Kerkhoff, G
    Budde, T
    Erbel, R
    Ewen, K
    Barkhausen, J
    RADIOLOGY, 2003, 226 (01) : 145 - 152
  • [3] Quantification of coronary artery calcium with multi-detector row CT: Assessing interscan variability with different tube currents - Pilot study
    Takahashi, N
    Bae, KT
    RADIOLOGY, 2003, 228 (01) : 101 - 106
  • [4] Spiral versus electron-beam CT for coronary artery calcium scoring
    Goldin, JG
    Yoon, HC
    Greaser, LE
    Heinze, SB
    McNitt-Gray, MM
    Brown, MS
    Sayre, JW
    Emerick, AM
    Aberle, DR
    RADIOLOGY, 2001, 221 (01) : 213 - 221
  • [5] Coronary artery calcium: Absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies
    Hong, C
    Becker, CR
    Schoepf, UJ
    Ohnesorge, B
    Bruening, R
    Reiser, MF
    RADIOLOGY, 2002, 223 (02) : 474 - 480
  • [6] Coronary artery calcium: Accuracy and reproducibility of measurements with multi-detector row CT - Assessment of effects of different thresholds and quantification methods
    Hong, C
    Bae, KT
    Pilgram, TK
    RADIOLOGY, 2003, 227 (03) : 795 - 801
  • [7] Coronary artery calcium measurement with multi-detector row CT: In vitro assessment of effect of radiation dose
    Hong, C
    Bae, KT
    Pilgram, TK
    Suh, J
    Bradley, D
    RADIOLOGY, 2002, 225 (03) : 901 - 906
  • [8] Multi-detector row CT versus coronary angiography: Preoperative evaluation before totally endoscopic coronary artery bypass grafting
    Herzog, C
    Dogan, S
    Diebold, T
    Khan, MF
    Ackermann, H
    Schaller, S
    Flohr, TG
    Wimmer-Greinecker, G
    Moritz, A
    Vogl, TJ
    RADIOLOGY, 2003, 229 (01) : 200 - 208
  • [9] Coronary artery calcium quantification at multi-detector row CT: Influence of heart rate and measurement methods on interaequisition variability - Initial experience
    Hong, C
    Bae, KT
    Pilgram, TK
    Zhu, F
    RADIOLOGY, 2003, 228 (01) : 95 - 100
  • [10] Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography
    Choi, HS
    Choi, BW
    Choe, KO
    Choi, DH
    Yoo, KJ
    Kim, MI
    Kim, J
    RADIOGRAPHICS, 2004, 24 (03) : 787 - 800