3T Magnetic Resonance Imaging Accurately Depicts Radiofrequency Ablation Zones in a Blood-perfused Bovine Liver Model

被引:6
作者
Burns, Stephanie K. [2 ]
Dodd, Gerald D., III [1 ]
McManus, Linda M. [3 ,4 ]
Cardan, Rex A. [5 ]
Peng, Qi [9 ,10 ]
Orsi, Michael D. [6 ]
Head, Hayden W. [7 ]
Blakemore, Dana L. [8 ]
Blume, Jeffrey D. [8 ]
Fullerton, Gary D. [1 ]
Green, Tyler J. [1 ]
机构
[1] Univ Colorado, Sch Med, Dept Radiol, Denver, CO 80202 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, Dept Radiol, San Antonio, TX 78229 USA
[3] Univ Texas Hlth Sci Ctr San Antonio, Dept Pathol, San Antonio, TX 78229 USA
[4] Univ Texas Hlth Sci Ctr San Antonio, Dept Periodont, San Antonio, TX 78229 USA
[5] Univ Alabama Birmingham, Dept Radiat Oncol, Birmingham, AL USA
[6] S Texas Radiol Grp, San Antonio, TX USA
[7] Cook Childrens Med Ctr, Ft Worth, TX USA
[8] Vanderbilt Univ, Sch Med, Dept Biostat, Nashville, TN 37212 USA
[9] Albert Einstein Coll Med, Dept Radiol, Bronx, NY 10467 USA
[10] Montefiore Med Ctr, Dept Radiol, Bronx, NY 10467 USA
关键词
HISTOPATHOLOGIC CORRELATION; HEPATOCELLULAR-CARCINOMA; RABBIT LIVER; METASTASES; LESION; TISSUE;
D O I
10.1016/j.jvir.2012.01.076
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine if noncontrast T1-weighted (T1W) images from 3T magnetic resonance (MR) imaging accurately depict radiofrequency (RF) ablation zones as determined macroscopically and microscopically in a blood-perfused bovine liver model. Materials and Methods: Three-dimensional (3D) gradient-recalled echo (GRE) T1W images were obtained on a 3T MR imaging scanner after RF ablations (n = 14) of in vitro blood-perfused bovine livers. The resulting central hypointense and peripheral hyperintense signal regions were measured and compared with the inner tan and outer red zones of the gross specimen. Corresponding ablated hepatic tissue samples were examined microscopically and stained with nicotinamide adenine dinucleotide phosphate (NADPH) to assess for the presence or absence of NADPH diaphorase activity. Bootstrap two-sample hypothesis tests were used to compare MR imaging, gross, and histopathologic measurements. Results: The MR imaging inner ablation zone had a mean radius of 0.80 cm (range 0.33-1.14 cm); the inner zone plus the outer ablation zone had a mean radius of 1.40 cm (range 1.01-1.74 cm). Comparison of the measurements of the inner ablation zone on MR imaging versus the gross specimen showed equivalence (95% confidence interval [CI] -0.122 cm, 0.223 cm). Comparison of the measurements of the outer ablation zone on MR imaging versus the gross and histologic specimens also showed equivalence (95% CI -0.095 cm, 0.244 cm, and -0.146 cm, 0.142 cm). Conclusions: Noncontrast 3D GRE T I W 3T MR imaging accurately depicts the RF ablation zones in a blood-perfused bovine liver model and can be used as a noninvasive means to assess the 3D morphologic characteristics of RF ablation lesions in the model.
引用
收藏
页码:801 / 808
页数:8
相关论文
共 18 条
[1]  
[Anonymous], 1993, An introduction to the bootstrap
[2]   What your statistician never told you about P-values [J].
Blume, J ;
Peipert, JF .
JOURNAL OF THE AMERICAN ASSOCIATION OF GYNECOLOGIC LAPAROSCOPISTS, 2003, 10 (04) :439-444
[3]  
Breen Michael S, 2004, Comput Aided Surg, V9, P185, DOI 10.1080/10929080500130330
[4]   Three-dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response [J].
Breen, MS ;
Lancaster, TL ;
Lazebnik, RS ;
Nour, SG ;
Lewin, JS ;
Wilson, DL .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (01) :90-102
[5]   Magnetic resonance imaging for hepatic radiofrequency ablation [J].
Clasen, S. ;
Boss, A. ;
Schmidt, D. ;
Fritz, J. ;
Schraml, C. ;
Claussen, C. D. ;
Pereira, P. L. .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 59 (02) :140-148
[6]   Minimally invasive treatment of malignant hepatic tumors: At the threshold of a major breakthrough [J].
Dodd, GD ;
Soulen, MC ;
Kane, RA ;
Livraghi, T ;
Lees, WR ;
Yamashita, Y ;
Gillams, AR ;
Karahan, OI ;
Rhim, H .
RADIOGRAPHICS, 2000, 20 (01) :9-27
[7]   Hepatic tumors treated with percutaneous radio-frequency ablation: CT and MR imaging follow-up [J].
Dromain, C ;
de Baere, T ;
Elias, D ;
Kuoch, V ;
Ducreux, M ;
Boige, V ;
Petrow, P ;
Roche, A ;
Sigal, R .
RADIOLOGY, 2002, 223 (01) :255-262
[8]   The abuse of power: The pervasive fallacy of power calculations for data analysis [J].
Hoenig, JM ;
Heisey, DM .
AMERICAN STATISTICIAN, 2001, 55 (01) :19-24
[9]   Hepatocellular carcinoma treated with radio frequency ablation: An early evaluation with magnetic resonance imaging [J].
Khankan, Azzam A. ;
Murakami, Takamichi ;
Onishi, Hiromitsu ;
Matsushita, Masaki ;
Iannaccone, Riccardo ;
Aoki, Yoshiko ;
Tono, Takeshi ;
Kim, Tonsok ;
Hori, Masatoshi ;
Osuga, Keigo ;
Passariello, Roberto ;
Nakamura, Hironobu .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) :546-551
[10]   Sub-acute changes in lesion conspicuity and geometry following MR-guided radiofrequency ablation [J].
Lazebnik, RS ;
Weinberg, BD ;
Breen, MS ;
Lewin, JS ;
Wilson, DL .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (03) :353-359