3D imaging of cone photoreceptors over extended time periods using optical coherence tomography with adaptive optics

被引:3
作者
Kocaoglu, Omer P. [1 ]
Lee, Sangyeol [1 ]
Jonnal, Ravi S. [1 ]
Wang, Qiang [1 ]
Herde, Ashley E. [1 ]
Besecker, Jason [1 ]
Gao, Weihua [1 ]
Miller, Donald T. [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
来源
OPHTHALMIC TECHNOLOGIES XXI | 2011年 / 7885卷
关键词
Optical Coherence Tomography; Adaptive Optics; Cone photoreceptors; SCANNING LASER OPHTHALMOSCOPY; CHROMATIC ABERRATION CORRECTION; LIVING HUMAN RETINA; MOTION CORRECTION; HUMAN EYE; RESOLUTION; SLO/OCT;
D O I
10.1117/12.878229
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography with adaptive optics (AO-OCT) is a highly sensitive, noninvasive method for 3D imaging of the microscopic retina. The purpose of this study is to advance AO-OCT technology by enabling repeated imaging of cone photoreceptors over extended periods of time (days). This sort of longitudinal imaging permits monitoring of 3D cone dynamics in both normal and diseased eyes, in particular the physiological processes of disc renewal and phagocytosis, which are disrupted by retinal diseases such as age related macular degeneration and retinitis pigmentosa. For this study, the existing AO-OCT system at Indiana underwent several major hardware and software improvements to optimize system performance for 4D cone imaging. First, ultrahigh speed imaging was realized using a Basler Sprint camera. Second, a light source with adjustable spectrum was realized by integration of an Integral laser (Femto Lasers, lambda(c)=800nm, Delta lambda=160nm) and spectral filters in the source arm. For cone imaging, we used a bandpass filter with lambda(c)=809nm and Delta lambda=81nm (2.6 mu m nominal axial resolution in tissue, and 167 KHz A-line rate using 1,408 px), which reduced the impact of eye motion compared to previous AO-OCT implementations. Third, eye motion artifacts were further reduced by custom ImageJ plugins that registered (axially and laterally) the volume videos. In two subjects, cone photoreceptors were imaged and tracked over a ten day period and their reflectance and outer segment (OS) lengths measured. High-speed imaging and image registration/dewarping were found to reduce eye motion to a fraction of a cone width (1 mu m root mean square). The pattern of reflections in the cones was found to change dramatically and occurred on a spatial scale well below the resolution of clinical instruments. Normalized reflectance of connecting cilia (CC) and OS posterior tip (PT) of an exemplary cone was 54 +/- 4, 47 +/- 4, 48 +/- 6, 50 +/- 5, 56 +/- 1% and 46 +/- 4, 53 +/- 4, 52 +/- 6, 50 +/- 5, 44 +/- 1% for days #1,3,6,8,10 respectively. OS length of the same cone was 28.9, 26.4, 26.4, 30.6, and 28.1 mu m for days # 1,3,6,8,10 respectively. It is plausible these changes are an optical correlate of the natural process of OS renewal and shedding.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Adaptive optics-optical coherence tomography for in vivo retinal imaging: comparative analysis of two wavefront correctors
    Zawadzki, Robert J.
    Jones, Steven M.
    Zhao, Mingtao
    Choi, Stacey S.
    Laut, Sophie S.
    Olivier, Scot S.
    Izatt, Joseph A.
    Werner, John S.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [42] In vitro 3D anterior segment imaging in lamb eye with extended depth range swept source optical coherence tomography
    Poddar, Raju
    Reddikumar, Maddipatla
    OPTICS AND LASER TECHNOLOGY, 2015, 67 : 33 - 37
  • [43] 3D Printed Phantoms of Retinal Photoreceptor Cells for Evaluating Adaptive Optics Imaging Modalities
    Kedia, Nikita
    Liu, Zhuolin
    Sochol, Ryan
    Hammer, Daniel X.
    Agrawal, Anant
    OPHTHALMIC TECHNOLOGIES XXVIII, 2018, 10474
  • [44] Motion-free volumetric retinal imaging with adaptive optics spectral-domain optical coherence tomography
    Zhang, Yan
    Rha, Jungtae
    Cense, Abraham
    Jonnal, Ravi S.
    Gao, Weihua
    Zawadzki, Robert J.
    Werner, John S.
    Jones, Steve
    Olivier, Scot
    Miller, Donald T.
    OPHTHALMIC TECHNOLOGIES XVI, 2006, 6138
  • [45] Cellular resolution volumetric in vivo retinal imaging with adaptive optics-optical coherence tomography
    Zawadzki, Robert J.
    Choi, Stacey S.
    Fuller, Alfred R.
    Evans, Julia W.
    Hamann, Bernd
    Werner, John S.
    OPTICS EXPRESS, 2009, 17 (05): : 4084 - 4094
  • [46] Novel Application of Long Short-Term Memory Network for 3D to 2D Retinal Vessel Segmentation in Adaptive Optics-Optical Coherence Tomography Volumes
    Le, Christopher T.
    Wang, Dongyi
    Villanueva, Ricardo
    Liu, Zhuolin
    Hammer, Daniel X.
    Tao, Yang
    Saeedi, Osamah J.
    APPLIED SCIENCES-BASEL, 2021, 11 (20):
  • [47] A SPATIOTEMPORAL ILLUMINATION MODEL FOR 3D IMAGE FUSION IN OPTICAL COHERENCE TOMOGRAPHY
    Ploner, Stefan
    Won, Jungeun
    Schottenhamml, Julia
    Girgis, Jessica
    Lam, Kenneth
    Waheed, Nadia
    Fujimoto, James
    Maier, Andreas
    2023 IEEE 20TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, ISBI, 2023,
  • [48] Imaging Foveal Microvasculature: Optical Coherence Tomography Angiography Versus Adaptive Optics Scanning Light Ophthalmoscope Fluorescein Angiography
    Mo, Shelley
    Krawitz, Brian
    Efstathiadis, Eleni
    Geyman, Lawrence
    Weitz, Rishard
    Chui, Toco Y. P.
    Carroll, Joseph
    Dubra, Alfredo
    Rosen, Richard B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT130 - OCT140
  • [49] Adaptive optics using a liquid crystal spatial light modulator for ultrahigh-resolution optical coherence tomography
    Fernandez, Enrique J.
    Povazay, Boris
    Hermann, Boris
    Unterhuber, Angelika
    Sattmann, Harald
    Prieto, Pedro M.
    Leitgeb, Rainer
    Ahnelt, Peter
    Artal, Pablo
    Drexler, Wolfgang
    OPHTHALMIC TECHNOLOGIES XVI, 2006, 6138
  • [50] 3D visualization of tissue microstructures using optical coherence tomography needle probes
    Kirk, Rodney W.
    McLaughlin, Robert A.
    Quirk, Bryden C.
    Curatolo, Andrea
    Sampson, David D.
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753