3D imaging of cone photoreceptors over extended time periods using optical coherence tomography with adaptive optics

被引:3
作者
Kocaoglu, Omer P. [1 ]
Lee, Sangyeol [1 ]
Jonnal, Ravi S. [1 ]
Wang, Qiang [1 ]
Herde, Ashley E. [1 ]
Besecker, Jason [1 ]
Gao, Weihua [1 ]
Miller, Donald T. [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
来源
OPHTHALMIC TECHNOLOGIES XXI | 2011年 / 7885卷
关键词
Optical Coherence Tomography; Adaptive Optics; Cone photoreceptors; SCANNING LASER OPHTHALMOSCOPY; CHROMATIC ABERRATION CORRECTION; LIVING HUMAN RETINA; MOTION CORRECTION; HUMAN EYE; RESOLUTION; SLO/OCT;
D O I
10.1117/12.878229
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography with adaptive optics (AO-OCT) is a highly sensitive, noninvasive method for 3D imaging of the microscopic retina. The purpose of this study is to advance AO-OCT technology by enabling repeated imaging of cone photoreceptors over extended periods of time (days). This sort of longitudinal imaging permits monitoring of 3D cone dynamics in both normal and diseased eyes, in particular the physiological processes of disc renewal and phagocytosis, which are disrupted by retinal diseases such as age related macular degeneration and retinitis pigmentosa. For this study, the existing AO-OCT system at Indiana underwent several major hardware and software improvements to optimize system performance for 4D cone imaging. First, ultrahigh speed imaging was realized using a Basler Sprint camera. Second, a light source with adjustable spectrum was realized by integration of an Integral laser (Femto Lasers, lambda(c)=800nm, Delta lambda=160nm) and spectral filters in the source arm. For cone imaging, we used a bandpass filter with lambda(c)=809nm and Delta lambda=81nm (2.6 mu m nominal axial resolution in tissue, and 167 KHz A-line rate using 1,408 px), which reduced the impact of eye motion compared to previous AO-OCT implementations. Third, eye motion artifacts were further reduced by custom ImageJ plugins that registered (axially and laterally) the volume videos. In two subjects, cone photoreceptors were imaged and tracked over a ten day period and their reflectance and outer segment (OS) lengths measured. High-speed imaging and image registration/dewarping were found to reduce eye motion to a fraction of a cone width (1 mu m root mean square). The pattern of reflections in the cones was found to change dramatically and occurred on a spatial scale well below the resolution of clinical instruments. Normalized reflectance of connecting cilia (CC) and OS posterior tip (PT) of an exemplary cone was 54 +/- 4, 47 +/- 4, 48 +/- 6, 50 +/- 5, 56 +/- 1% and 46 +/- 4, 53 +/- 4, 52 +/- 6, 50 +/- 5, 44 +/- 1% for days #1,3,6,8,10 respectively. OS length of the same cone was 28.9, 26.4, 26.4, 30.6, and 28.1 mu m for days # 1,3,6,8,10 respectively. It is plausible these changes are an optical correlate of the natural process of OS renewal and shedding.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] OPTICAL COHERENCE TOMOGRAPHY FOR THE IMAGING OF 3D CELL CULTURES - CHANCES AND OPPORTUNITIES
    Hachgenei, Enno
    Schmitt, Robert H.
    TISSUE ENGINEERING PART A, 2022, 28 : S156 - S156
  • [32] Correction of Motion Artifact in 3D Retinal Optical Coherence Tomography Imaging
    He, Haijiao
    Liu, Guozhong
    Mo, Peng
    Li, Bo
    Wu, JiaLun
    Ding, XiangYou
    2013 6TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), VOLS 1-3, 2013, : 261 - 265
  • [33] In vivo imaging of human retinal ganglion cells using optical coherence tomography without adaptive optics
    Zhang, Furu
    Kovalick, Katherine
    Raghavendra, Achyut
    Soltanian-Zadeh, Somayyeh
    Farsiu, Sina
    Hammer, Daniel X.
    Liu, Zhuolin
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (08): : 4675 - 4688
  • [34] Adaptive optics-assisted optical coherence tomography for imaging of patients with age related macular degeneration
    Sudo, Kenta
    Cense, Barry
    OPHTHALMIC TECHNOLOGIES XXIII, 2013, 8567
  • [35] High resolution retinal imaging with a compact adaptive optics spectral domain optical coherence tomography system
    Hammer, Daniel X.
    Iftimia, Nicusor V.
    Bigelow, Chad E.
    Ustun, Teoman E.
    Bloom, Benjamin
    Ferguson, R. Daniel
    Burns, Stephen A.
    OPHTHALMIC TECHNOLOGIES XVII, 2007, 6426
  • [36] Retinal imaging with optical coherence tomography and low-loss adaptive optics using a 2.8-mm beam size
    Maddipatla, Reddikumar
    Cervantes, Joel
    Otani, Yukitoshi
    Cense, Barry
    JOURNAL OF BIOPHOTONICS, 2019, 12 (06)
  • [37] In situ volumetric imaging and analysis of FRESH 3D bioprinted constructs using optical coherence tomography
    Tashman, Joshua W.
    Shiwarski, Daniel J.
    Coffin, Brian
    Ruesch, Alexander
    Lanni, Frederick
    Kainerstorfer, Jana M.
    Feinberg, Adam W.
    BIOFABRICATION, 2023, 15 (01)
  • [38] 3D High-resolution Subsurface Fingerprint Imaging using Superresolution Optical Coherence Tomography
    Shen, Kai
    Baig, Sarfaraz
    Palacios, Diego
    Wang, Michael R.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXIII, 2019, 10867
  • [39] Imaging of retinal ganglion cells and photoreceptors using Spatio-Temporal Optical Coherence Tomography (STOC-T) without hardware-based adaptive optics
    Mikula-Zdankowska, Marta
    Borycki, Dawid
    Wegrzyn, Piotr
    Adomavicius, Karolis
    Auksorius, Egidijus
    Wojtkowski, Maciej
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2025, 45 (01) : 52 - 61
  • [40] Adaptive optics-optical coherence tomography for in vivo retinal imaging: effects of spectral bandwidth on image quality
    Zawadzki, Robert J.
    Jones, Steven M.
    Zhao, Mingtao
    Choi, Stacey S.
    Laut, Sophie S.
    Olivier, Scot S.
    Izatt, Joseph A.
    Wemer, John S.
    OPHTHALMIC TECHNOLOGIES XVI, 2006, 6138