3D imaging of cone photoreceptors over extended time periods using optical coherence tomography with adaptive optics

被引:3
|
作者
Kocaoglu, Omer P. [1 ]
Lee, Sangyeol [1 ]
Jonnal, Ravi S. [1 ]
Wang, Qiang [1 ]
Herde, Ashley E. [1 ]
Besecker, Jason [1 ]
Gao, Weihua [1 ]
Miller, Donald T. [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
来源
OPHTHALMIC TECHNOLOGIES XXI | 2011年 / 7885卷
关键词
Optical Coherence Tomography; Adaptive Optics; Cone photoreceptors; SCANNING LASER OPHTHALMOSCOPY; CHROMATIC ABERRATION CORRECTION; LIVING HUMAN RETINA; MOTION CORRECTION; HUMAN EYE; RESOLUTION; SLO/OCT;
D O I
10.1117/12.878229
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography with adaptive optics (AO-OCT) is a highly sensitive, noninvasive method for 3D imaging of the microscopic retina. The purpose of this study is to advance AO-OCT technology by enabling repeated imaging of cone photoreceptors over extended periods of time (days). This sort of longitudinal imaging permits monitoring of 3D cone dynamics in both normal and diseased eyes, in particular the physiological processes of disc renewal and phagocytosis, which are disrupted by retinal diseases such as age related macular degeneration and retinitis pigmentosa. For this study, the existing AO-OCT system at Indiana underwent several major hardware and software improvements to optimize system performance for 4D cone imaging. First, ultrahigh speed imaging was realized using a Basler Sprint camera. Second, a light source with adjustable spectrum was realized by integration of an Integral laser (Femto Lasers, lambda(c)=800nm, Delta lambda=160nm) and spectral filters in the source arm. For cone imaging, we used a bandpass filter with lambda(c)=809nm and Delta lambda=81nm (2.6 mu m nominal axial resolution in tissue, and 167 KHz A-line rate using 1,408 px), which reduced the impact of eye motion compared to previous AO-OCT implementations. Third, eye motion artifacts were further reduced by custom ImageJ plugins that registered (axially and laterally) the volume videos. In two subjects, cone photoreceptors were imaged and tracked over a ten day period and their reflectance and outer segment (OS) lengths measured. High-speed imaging and image registration/dewarping were found to reduce eye motion to a fraction of a cone width (1 mu m root mean square). The pattern of reflections in the cones was found to change dramatically and occurred on a spatial scale well below the resolution of clinical instruments. Normalized reflectance of connecting cilia (CC) and OS posterior tip (PT) of an exemplary cone was 54 +/- 4, 47 +/- 4, 48 +/- 6, 50 +/- 5, 56 +/- 1% and 46 +/- 4, 53 +/- 4, 52 +/- 6, 50 +/- 5, 44 +/- 1% for days #1,3,6,8,10 respectively. OS length of the same cone was 28.9, 26.4, 26.4, 30.6, and 28.1 mu m for days # 1,3,6,8,10 respectively. It is plausible these changes are an optical correlate of the natural process of OS renewal and shedding.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Imaging modal content of cone photoreceptors using adaptive optics optical coherence tomography
    Liu, Zhuolin
    Kocaoglu, Omer P.
    Turner, Timothy L.
    Miller, Donald T.
    OPHTHALMIC TECHNOLOGIES XXV, 2015, 9307
  • [2] Imaging cone photoreceptors in three dimensions and in time using ultrahigh resolution optical coherence tomography with adaptive optics
    Kocaoglu, Omer P.
    Lee, Sangyeol
    Jonnal, Ravi S.
    Wang, Qiang
    Herde, Ashley E.
    Derby, Jack C.
    Gao, Weihua
    Miller, Donald T.
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (04): : 748 - 763
  • [3] Adaptive optics optical coherence tomography for measuring phase and reflectance dynamics of photoreceptors
    Kocaoglu, Omer P.
    Jonnal, Ravi S.
    Lee, Sangyeol
    Wang, Qiang
    Liu, Zhuolin
    Miller, Donald T.
    OPHTHALMIC TECHNOLOGIES XXII, 2012, 8209
  • [4] Adaptive optics SLO/OCT for 3D imaging of human photoreceptors in vivo
    Felberer, Franz
    Kroisamer, Julia-Sophie
    Baumann, Bernhard
    Zotter, Stefan
    Schmidt-Erfurth, Ursula
    Hitzenberger, Christoph K.
    Pircher, Michael
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (02): : 439 - 456
  • [5] Imaging retinal nerve fiber bundles using optical coherence tomography with adaptive optics
    Kocaoglu, Omer P.
    Cense, Barry
    Jonnal, Ravi S.
    Wang, Qiang
    Lee, Sangyeol
    Gao, Weihua
    Miller, Donald T.
    VISION RESEARCH, 2011, 51 (16) : 1835 - 1844
  • [6] First steps toward 3D high resolution imaging using adaptive optics and full-field optical coherence tomography
    Blanco, Leonardo
    Blavier, Marie
    Glanc, Marie
    Pouplard, Florence
    Tick, Sarah
    Maksimovic, Ivan
    Chenegros, Guillaume
    Mugnier, Laurent
    Lacombe, Francois
    Rousset, Gerard
    Paques, Michel
    Le Gargasson, Jean-Francois
    Sahel, Jose-Alain
    1ST CANTERBURY WORKSHOP ON OPTICAL COHERENCE TOMOGRAPHY AND ADAPTIVE OPTICS, 2008, 7139
  • [7] Adaptive optics optical coherence tomography for in vivo mouse retinal imaging
    Jian, Yifan
    Zawadzki, Robert J.
    Sarunic, Marinko V.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
  • [8] Dual modality handheld adaptive optics optical coherence tomography probe for in vivo 3-D photoreceptor imaging
    Hagan, Kristen
    Park, Jongwan
    DuBose, Theodore B.
    Soltanian-Zadeh, Somayyeh
    Dhalla, Al-Hafeez
    Kuo, Anthony N.
    McNabb, Ryan P.
    Izatt, Joseph A.
    Farsiu, Sina
    OPHTHALMIC TECHNOLOGIES XXXIII, 2023, 12360
  • [9] Imaging human retinal pigment epithelium cells using adaptive optics optical coherence tomography
    Liu, Zhuolin
    Kocaoglu, Omer P.
    Turner, Timothy L.
    Miller, Donald T.
    OPHTHALMIC TECHNOLOGIES XXVI, 2016, 9693
  • [10] Retinal Imaging with a Combined Adaptive Optics - Optical Coherence Tomography and Adaptive Optics - Scanning Laser Ophthalmoscopy System
    Zawadzki, Robert J.
    Jones, Steven M.
    Pilli, Suman
    Kim, Dae Yu
    Olivier, Scot S.
    Werner, John S.
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550