Power system transmission line parameters are essential in monitoring and control applications. More specifically, the values of the transmission line parameters are used in state estimation, contingency analysis, and as settings in protection relays. However, the stored transmission line parameters in the control center database often deviate from their actual values, impacting negatively the applications of the power system control center. The use of PMU (Phasor Measurement Unit) measurements is the most convenient and simple way for refining the parameters of the transmission line; however, the contamination of the PMU measurements with noise from the instrument transformers and the communication channels could sometimes deteriorate the accuracy of the calculated parameters. In this paper, the denoising of the PMU measurements using wavelets is proposed prior to the calculation of the transmission line parameters. The proposed approach is used for calculating the transmission line parameters of the IEEE 14-bus system and the results are extensively discussed.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] A charge simulation based-method for an accurate calculation of transmission line capacitances
    AbdelSalam, M
    AbdelAziz, EZ
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 1995, 20 (4B): : 799 - 807
  • [32] Simultaneous Transmission Line Parameter and PMU Measurement Calibration
    Wu, Zhongyu
    Zora, Leydi T.
    Phadke, Arun G.
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [33] On-Line PMU-Based Transmission Line Parameter Identification
    Zhao, Xuanyu
    Zhou, Huafeng
    Shi, Di
    Zhao, Huashi
    Jing, Chaoyang
    Jones, Chris
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2015, 1 (02): : 68 - 74
  • [34] Parameters selection for lightning protection calculation for transmission line in Chongqing grid
    Chongqing Electric Power Test and Research Institute, Chongqing 400015, China
    不详
    Gaodianya Jishu, 2007, 12 (162-163+172): : 162 - 163
  • [35] Calibration Method of Phase Angle Difference for PMU at Both Ends of Transmission Line with Its Unknown Parameters
    Xue A.
    Xu J.
    Xu F.
    You H.
    Chow J.H.
    Bi T.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (12): : 129 - 135
  • [36] Accurate Transmission Line Fault Location Considering Shunt Capacitances Without Utilizing Line Parameters
    Xiu, Wanjing
    Liao, Yuan
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2011, 39 (16) : 1783 - 1794
  • [37] A Multistep Approach for Accurate Permittivity Measurements of Liquids Using a Transmission Line Method
    Zhao, Dongsheng
    Rietveld, Gert
    Teunisse, George M.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (07) : 2267 - 2274
  • [38] De-embedding transmission line measurements for accurate modeling of IC designs
    Mangan, AM
    Voinigescu, SP
    Yang, MT
    Tazlauanu, M
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2006, 53 (02) : 235 - 241
  • [39] Online estimation of transformer parameters based on PMU measurements
    Wang, Maohai
    Qi, Xia
    Niu, Siqing
    Han, Fukun
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2011, 35 (13): : 61 - 65
  • [40] Estimation of Load Model Parameters from PMU Measurements
    Regulski, P.
    Wall, P.
    Rusidovic, Z.
    Terzija, V.
    2014 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT EUROPE), 2014,