Denoising of PMU Measurements for Accurate Calculation of Transmission Line Parameters

被引:0
|
作者
Asprou, Markos [1 ]
Kyriakides, Elias [1 ]
机构
[1] Univ Cyprus, Dept Elect & Comp Engn, KIOS Res & Innovat Ctr Excellence, Nicosia, Cyprus
关键词
Discrete wavelet transform; noise; phasor measurement unit; signal denoising; transmission lines;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Power system transmission line parameters are essential in monitoring and control applications. More specifically, the values of the transmission line parameters are used in state estimation, contingency analysis, and as settings in protection relays. However, the stored transmission line parameters in the control center database often deviate from their actual values, impacting negatively the applications of the power system control center. The use of PMU (Phasor Measurement Unit) measurements is the most convenient and simple way for refining the parameters of the transmission line; however, the contamination of the PMU measurements with noise from the instrument transformers and the communication channels could sometimes deteriorate the accuracy of the calculated parameters. In this paper, the denoising of the PMU measurements using wavelets is proposed prior to the calculation of the transmission line parameters. The proposed approach is used for calculating the transmission line parameters of the IEEE 14-bus system and the results are extensively discussed.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Estimation of transmission line parameters from measurements
    Indulkar, C. S.
    Ramalingam, K.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2008, 30 (05) : 337 - 342
  • [22] Calculation of Transmission Line Parameters: A real Case Study
    Economides, Xenios
    Asprou, Markos
    Stavrou, Andreas
    2021 IEEE PES INNOVATIVE SMART GRID TECHNOLOGY EUROPE (ISGT EUROPE 2021), 2021, : 149 - 153
  • [23] Model for 400 kV Transmission Line Power Loss Assessment Using the PMU Measurements
    Pavicic, Ivan
    Holjevac, Ninoslav
    Ivankovic, Igor
    Brnobic, Dalibor
    ENERGIES, 2021, 14 (17)
  • [24] Robust Identification Method for Transmission Line Parameters That Considers PMU Phase Angle Error
    Xue, Ancheng
    Xu, Feiyang
    Martin, Kenneth E.
    You, Hongyu
    Wang, Li
    Wei, Guoen
    Xu, Jingsong
    IEEE ACCESS, 2020, 8 : 86962 - 86971
  • [25] Correction of Phasor Measurements Independent of Transmission Line Parameters
    Xue, Ancheng
    Xu, Feiyang
    Xu, Jingsong
    Chow, Joe H.
    You, Hongyu
    Bi, Tianshu
    IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (01) : 346 - 356
  • [26] On-line Estimation of Transmission Line Parameters Using Synchronized Measurements
    Al-Othman, Abdulrahman K.
    El-Naggar, Khaled M.
    AlSharidah, Michel E.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (02) : 233 - 239
  • [27] Correction of Time-varying PMU Phase Angle Deviation with Unknown Transmission Line Parameters
    Xue, Ancheng
    Kong, He
    Xu, Feiyang
    Zhao, Junbo
    Chang, Naichao
    Chow, Joe H.
    Hong, Haiyan
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2023, 9 (01): : 315 - 325
  • [28] Development of Efficient and Robust Methods for Estimation of Transmission Line Parameters Using Synchronized PMU Data
    Lahmar, Mustafa
    Liao, Yuan
    IEEE SOUTHEASTCON 2018, 2018,
  • [29] Refinement of Transmission Line Equivalent Circuit Parameters at Power System State Estimation by PMU Data
    Kolosok, I
    Korkina, E.
    ADVANCES IN AUTOMATION, 2020, 641 : 571 - 580