HPAEC-PAD for oligosaccharide analysis-novel insights into analyte sensitivity and response stability

被引:37
作者
Mechelke, Matthias [1 ]
Herlet, Jonathan [1 ]
Benz, J. Philipp [2 ]
Schwarz, Wolfgang H. [1 ]
Zverlov, Vladimir V. [1 ,3 ]
Liebl, Wolfgang [1 ]
Kornberger, Petra [1 ]
机构
[1] Tech Univ Munich, TUM Sch Life Sci Weihenstephan, Dept Microbiol, Emil Ramann Str 4, D-85354 Freising Weihenstephan, Germany
[2] Tech Univ Munich, TUM Sch Life Sci Weihenstephan, Professorship Wood Bioproc, Hans Carl von Carlowitz Pl 2, D-85354 Freising Weihenstephan, Germany
[3] Russian Acad Sci, Inst Mol Genet, Kurchatov Sq 2, Moscow 123182, Russia
关键词
HPAEC-PAD; Oligosaccharide analysis; XOS; AXOS; PAD response factor; Data normalization; ANION-EXCHANGE CHROMATOGRAPHY; PULSED AMPEROMETRIC DETECTION; ARABINOXYLAN-OLIGOSACCHARIDES; ACID; XYLOOLIGOSACCHARIDES; PREBIOTICS;
D O I
10.1007/s00216-017-0678-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The rising importance of accurately detecting oligosaccharides in biomass hydrolyzates or as ingredients in food, such as in beverages and infant milk products, demands for the availability of tools to sensitively analyze the broad range of available oligosaccharides. Over the last decades, HPAEC-PAD has been developed into one of the major technologies for this task and represents a popular alternative to state-of-the-art LC-MS oligosaccharide analysis. This work presents the first comprehensive study which gives an overview of the separation of 38 analytes as well as enzymatic hydrolyzates of six different polysaccharides focusing on oligosaccharides. The high sensitivity of the PAD comes at cost of its stability due to recession of the gold electrode. By an in-depth analysis of the sensitivity drop over time for 35 analytes, including xylo- (XOS), arabinoxylo- (AXOS), laminari- (LOS), manno- (MOS), glucomanno- (GMOS), and cellooligosaccharides (COS), we developed an analyte-specific one-phase decay model for this effect over time. Using this model resulted in significantly improved data normalization when using an internal standard. Our results thereby allow a quantification approach which takes the inevitable and analyte-specific PAD response drop into account.
引用
收藏
页码:7169 / 7181
页数:13
相关论文
共 46 条
  • [31] Development of an Ion-Exchange Chromatography Method for Monitoring the Degradation of Prebiotic Arabinoxylan-Oligosaccharides in a Complex Fermentation Medium
    Riviere, Audrey
    Eeltink, Sebastiaan
    Pierlot, Christophe
    Balzarini, Tom
    Moens, Frederic
    Selak, Marija
    De Vuyst, Luc
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (10) : 4982 - 4990
  • [32] Prebiotics: The concept revisited
    Roberfroid, Marcel
    [J]. JOURNAL OF NUTRITION, 2007, 137 (03) : 830S - 837S
  • [33] Rohrer J., 2017, TECHNICAL NOTE 21 OP
  • [34] Rohrer J, 2017, TECHNICAL NOTE 20 AN
  • [35] Rohrer J, 2017, TECHNICAL NOTE 133 H
  • [36] Analysis of the N-acetylneuraminic acid and N-glycolylneuraminic acid contents of glycoproteins by high-pH anion-exchange chromatography with pulsed amperometric detection (HPAEC/PAD)
    Rohrer, JS
    Thayer, J
    Weitzhandler, M
    Avdalovic, N
    [J]. GLYCOBIOLOGY, 1998, 8 (01) : 35 - 43
  • [37] Samuelsen AB, 1999, CARBOHYDR RES
  • [38] Sasagawa T, 1989, J CHROMATOGR A
  • [39] Schaffler K.J, 1996, P S AFR SUG TECHN AS, V70, P241
  • [40] Spinner J, 2013, PREBIOTICS MARKET HI