Bone remodelling patterns around orthodontic mini-implants migrating in bone: an experimental study in rat vertebrae

被引:5
作者
Becker, Kathrin [1 ]
Rauch, Nicole [2 ]
Brunello, Giulia [2 ,3 ]
Azimi, Sarah [1 ]
Beller, Mathias [4 ,5 ]
Hufner, Mira [1 ]
Nienkemper, Manuel [1 ]
Schwarz-Herzke, Beryl [6 ]
Drescher, Dieter [1 ]
机构
[1] Univ Clin Dusseldorf, Dept Orthodont, Moorenstr 5, D-40225 Dusseldorf, Germany
[2] Univ Clin Dusseldorf, Dept Oral Surg, Dusseldorf, Germany
[3] Univ Padua, Dept Neurosci, Padua, Italy
[4] Univ Dusseldorf, Inst Math Modeling Biol Syst, Dusseldorf, Germany
[5] Univ Dusseldorf, Syst Biol Lipid Metab, Dusseldorf, Germany
[6] Univ Clin Dusseldorf, Inst Anat 2, Dusseldorf, Germany
关键词
PALATAL IMPLANTS; IN-VIVO; SCLEROSTIN; OSTEOCYTES; MINISCREWS; EXPRESSION; IMMEDIATE; ANCHORAGE; SECTIONS; OSTERIX;
D O I
10.1093/ejo/cjab065
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Orthodontic implant migration has been clinically observed in presence of continuous loading forces. Recent studies indicate that osteocytes play a crucial role in this phenomenon. Objectives: Aim of this study was to investigate local osteocytic gene expression, protein expression, and bone micro-structure in peri-implant regions of pressure and tension. Material and methods: The present work reports a complementary analysis to a previous micro-computed tomography study. Two customized mini-implants were placed in one caudal rat vertebra and connected by a nickel-titanium contraction spring generating different forces (i.e. 0, 0.5, 1.0, and 1.5 N). Either at 2 or 8 weeks, the vertebrae were harvested and utilized for 1. osteocytic gene expression using laser capture micro-dissection on frozen sections coupled with qPCR, 2. haematoxylin-eosin staining for qualitative and quantitative analyses, 3. immunofluorescence staining and analysis, and 4. bone-to-implant contact on undecalcified samples. Results: At the two time points for all the performed analyses no significant differences were observed with respect to the applied force magnitudes and cell harvesting localization. However, descriptive histological analysis revealed remarkable bone remodelling at 2 weeks of loading. At 8 weeks the implants were osseointegrated and, especially in 1.0 and 1.5 N groups, newly formed bone presented a characteristic load bearing architecture with trabecula oriented in the direction of the loading. Conclusions: The present study confirmed that stress-induced bone remodelling is the biological mechanism of orthodontic implant migration. Bone apposition was found at 'tension' and 'pressure' sites thus limiting implant migration over time.
引用
收藏
页码:708 / 717
页数:10
相关论文
共 50 条
[1]   Maximum principal strain as a criterion for prediction of orthodontic mini-implants failure in subject-specific finite element models [J].
Albogha, Mhd Hassan ;
Kitahara, Toru ;
Todo, Mitsugu ;
Hyakutake, Hiroto ;
Takahashi, Ichiro .
ANGLE ORTHODONTIST, 2016, 86 (01) :24-31
[2]   Assessment of mini-implant displacement using cone beam computed tomography [J].
Alves, Matheus, Jr. ;
Baratieri, Carolina ;
Nojima, Lincoln Issamu .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (10) :1151-1156
[3]   Fitting Linear Mixed-Effects Models Using lme4 [J].
Bates, Douglas ;
Maechler, Martin ;
Bolker, Benjamin M. ;
Walker, Steven C. .
JOURNAL OF STATISTICAL SOFTWARE, 2015, 67 (01) :1-48
[4]   Can implants move in bone? A longitudinal in vivo micro-CT analysis of implants under constant forces in rat vertebrae [J].
Becker, Kathrin ;
Schwarz, Frank ;
Rauch, Nicole Jasmin ;
Khalaph, Silava ;
Mihatovic, Ilja ;
Drescher, Dieter .
CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (12) :1179-1189
[5]  
Becker K, 2018, IMPLANTOLOGIE, V26, P85
[6]   Automated 3D-2D registration of X-ray microcomputed tomography with histological sections for dental implants in bone using chamfer matching and simulated annealing [J].
Becker, Kathrin ;
Stauber, Martin ;
Schwarz, Frank ;
Beissbarth, Tim .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 44 :62-68
[7]   Osteocyte-Driven Bone Remodeling [J].
Bellido, Teresita .
CALCIFIED TISSUE INTERNATIONAL, 2014, 94 (01) :25-34
[8]   Cathepsin K Controls Cortical Bone Formation by Degrading Periostin [J].
Bonnet, Nicolas ;
Brun, Julia ;
Rousseau, Jean-Charles ;
Duong, Le T. ;
Ferrari, Serge L. .
JOURNAL OF BONE AND MINERAL RESEARCH, 2017, 32 (07) :1432-1441
[9]   Osteocytes and mechanical loading: The Wnt connection [J].
Bullock, Whitney A. ;
Pavalko, Frederick M. ;
Robling, Alexander G. .
ORTHODONTICS & CRANIOFACIAL RESEARCH, 2019, 22 :175-179
[10]   Bone morphology allows estimation of loading history in a murine model of bone adaptation [J].
Christen, Patrik ;
van Rietbergen, Bert ;
Lambers, Floor M. ;
Mueller, Ralph ;
Ito, Keita .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2012, 11 (3-4) :483-492