MColiPAT kit for early detection of coliforms in water

被引:3
|
作者
Tambi, Ashish [1 ]
Brighu, Urmila [1 ]
Gupta, A. B. [1 ]
机构
[1] Malaviya Natl Inst Technol, Dept Civil Engn, Jaipur 302017, Rajasthan, India
关键词
coliforms; Colilert; indicator; most probable number; rapid detection; water; PHENOL RED; ENUMERATION;
D O I
10.2166/ws.2020.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Determining the microbial quality of drinking water by assessing the presence/absence (P/A) or enumeration of indicator bacteria continues to be widely practiced worldwide. However, rapid tests are required for microbiological water quality assessment so that the information is available in the shortest possible time for initiating a timely intervention. Traditional methods for the enumeration of indicator bacteria are not only expensive but also need trained personnel. We have developed a low-cost kit, (M)ColiPAT, and have validated its application for detection of coliforms in drinking water using the IDEXX Colilert-18 Quanti tray method. (M)ColiPAT kit medium was able to detect coliforms down to a level of 3.1 MPN/100 ml within 10.5 hours. The sensitivity and specificity of the kit were 95.45% and 100% respectively. (M)ColiPAT is found to be reliable and accurate for the detection of coliforms in drinking water.
引用
收藏
页码:871 / 877
页数:7
相关论文
共 50 条
  • [31] Use of two presence/absence systems for the detection of E-coli and coliforms from water
    Fricker, EJ
    Fricker, CR
    WATER RESEARCH, 1996, 30 (09) : 2226 - 2228
  • [32] Microbial water quality: Voltammetric detection of coliforms based on riboflavin-ferrocyanide redox couples
    Bigham, Teri
    Casimero, Charnete
    Dooley, James S. G.
    Ternan, Nigel G.
    Snelling, William J.
    Davis, James
    ELECTROCHEMISTRY COMMUNICATIONS, 2019, 101 (99-103) : 99 - 103
  • [33] EVALUATION OF RECOVERY METHODS TO DETECT COLIFORMS IN WATER
    BISSONNETTE, GK
    JEZESKI, JJ
    MCFETERS, GA
    STUART, DG
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1977, 33 (03) : 590 - 595
  • [34] Evaluation of new chromogenic substrates for the detection of coliforms
    Browne, N. K.
    Huang, Z.
    Dockrell, M.
    Hashmi, P.
    Price, R. G.
    JOURNAL OF APPLIED MICROBIOLOGY, 2010, 108 (05) : 1828 - 1838
  • [35] ENUMERATING INJURED COLIFORMS IN DRINKING-WATER
    LECHEVALLIER, MW
    MCFETERS, GA
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1985, 77 (06): : 81 - 87
  • [36] A COMBINED CHROMOGENIC-FLUOROGENIC MEDIUM FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND ESCHERICHIA-COLI IN WATER
    MANAFI, M
    KNEIFEL, W
    ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1989, 189 (03): : 225 - 234
  • [37] DESTRUCTION OF COLIFORMS IN WATER AND SEWAGE WATER BY DYE-SENSITIZED PHOTOOXIDATION
    ACHER, AJ
    JUVEN, BJ
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1977, 33 (05) : 1019 - 1022
  • [38] The fate of environmental coliforms in a model water distribution system
    Thames Water Utilities Ltd., Reading, United Kingdom
    不详
    不详
    不详
    Lett. Appl. Microbiol., 2 (93-97):
  • [39] The fate of environmental coliforms in a model water distribution system
    McMath, SM
    Sumpter, C
    Holt, DM
    Delanoue, A
    Chamberlain, AHL
    LETTERS IN APPLIED MICROBIOLOGY, 1999, 28 (02) : 93 - 97
  • [40] EFFECT OF STORAGE TEMPERATURE AND TIME ON COLIFORMS IN WATER SAMPLES
    TAYLOR, EW
    WATER RESEARCH, 1967, 1 (04) : 317 - &