MColiPAT kit for early detection of coliforms in water

被引:3
|
作者
Tambi, Ashish [1 ]
Brighu, Urmila [1 ]
Gupta, A. B. [1 ]
机构
[1] Malaviya Natl Inst Technol, Dept Civil Engn, Jaipur 302017, Rajasthan, India
关键词
coliforms; Colilert; indicator; most probable number; rapid detection; water; PHENOL RED; ENUMERATION;
D O I
10.2166/ws.2020.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Determining the microbial quality of drinking water by assessing the presence/absence (P/A) or enumeration of indicator bacteria continues to be widely practiced worldwide. However, rapid tests are required for microbiological water quality assessment so that the information is available in the shortest possible time for initiating a timely intervention. Traditional methods for the enumeration of indicator bacteria are not only expensive but also need trained personnel. We have developed a low-cost kit, (M)ColiPAT, and have validated its application for detection of coliforms in drinking water using the IDEXX Colilert-18 Quanti tray method. (M)ColiPAT kit medium was able to detect coliforms down to a level of 3.1 MPN/100 ml within 10.5 hours. The sensitivity and specificity of the kit were 95.45% and 100% respectively. (M)ColiPAT is found to be reliable and accurate for the detection of coliforms in drinking water.
引用
收藏
页码:871 / 877
页数:7
相关论文
共 50 条
  • [1] A sensitive presence/absence test kit for detection of coliforms in drinking water
    Tambi, Ashish
    Brighu, Urmila
    Gupta, A. B.
    WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2016, 16 (05): : 1320 - 1326
  • [2] Methods for detection and enumeration of coliforms in drinking water: a review
    Tambi, Ashish
    Brighu, Urmila
    Gupta, A. B.
    WATER SUPPLY, 2023, 23 (10) : 4047 - 4058
  • [3] FLUOROGENIC DETECTION OF ATYPICAL COLIFORMS FROM WATER SAMPLES
    CENCI, G
    CALDINI, G
    SFODERA, F
    MOROZZI, G
    MICROBIOLOGICA, 1990, 13 (02): : 121 - 129
  • [4] ANALYTICAL NOTES - ELECTROCHEMICAL METHOD FOR EARLY DETECTION AND MONITORING OF COLIFORMS
    WILKINS, JR
    BOYKIN, EH
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1976, 68 (05): : 257 - 263
  • [5] EVALUATION OF A KIT FOR EARLY DETECTION OF PREGNANCY
    GANGULY, M
    LEVITZ, M
    SCHWARTZ, MK
    NISSELBAUM, JS
    CLINICAL CHEMISTRY, 1980, 26 (11) : 1628 - 1629
  • [6] Molecular Method for Detection of Total Coliforms in Drinking Water Samples
    Maheux, Andree F.
    Boudreau, Dominique K.
    Bisson, Marc-Antoine
    Dion-Dupont, Vanessa
    Bouchard, Sebastien
    Nkuranga, Martine
    Bergeron, Michel G.
    Rodriguez, Manuel J.
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2014, 80 (14) : 4074 - 4084
  • [7] Assessing microbial water quality: Electroanalytical approaches to the detection of coliforms
    Bigham, Teri
    Dooley, James S. G.
    Ternan, Nigel G.
    Snelling, William J.
    Hector Castelan, M. C.
    Davis, James
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 121
  • [8] DETECTION OF COLIFORMS AND ENTEROBACTERIACEAE
    PETITT, SB
    JOURNAL OF APPLIED BACTERIOLOGY, 1983, 55 (03): : R7 - R7
  • [9] Detection and enumeration of coliforms in drinking water:: current methods and emerging approaches
    Rompré, A
    Servais, P
    Baudart, J
    de-Roubin, MR
    Laurent, P
    JOURNAL OF MICROBIOLOGICAL METHODS, 2002, 49 (01) : 31 - 54
  • [10] MODIFICATION OF DELAYED-INCUBATION PROCEDURE FOR DETECTION OF FECAL COLIFORMS IN WATER
    CHEN, M
    HICKEY, PJ
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1983, 46 (04) : 889 - 893