Electrochemical Immunoassay with Dual-Signal Amplification for Redox Cycling within a Nanoscale Gap

被引:5
作者
Ito, Kentaro [1 ]
Inoue, Kumi Y. [1 ,3 ]
Ito-Sasaki, Takahiro [1 ]
Ino, Kosuke [2 ]
Shiku, Hitoshi [2 ]
机构
[1] Tohoku Univ, Grad Sch Environm Studies, Sendai, Miyagi 9808579, Japan
[2] Tohoku Univ, Dept Biomol Engn, Grad Sch Engn, Sendai, Miyagi 9808579, Japan
[3] Univ Yamanashi, Fac Engn Grad Fac Interdisciplinary Res, Ctr Basic Educ, Kofu, Yamanashi 4008511, Japan
基金
日本学术振兴会; 日本科学技术振兴机构;
关键词
electrochemical immunosensor; redox cycling; Limulus amebocyte lysate reaction; endotoxin; ENDOTOXIN; SENSITIVITY; SENSOR; FLUCTUATIONS; MOLECULES; STRATEGY; SYSTEM; ARRAYS;
D O I
10.1021/acsanm.1c02837
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Here, we report a highly sensitive and easy-to-use electrochemical immunoassay using a dual-signal amplification strategy of redox cycling within a nanoscale gap and the Limulus amebocyte lysate (LAL) cascade reaction. After the antigen-antibody reaction using an endotoxin-labeled antibody, the LAL reaction was induced by endotoxin as the first signal amplification. Subsequently, p-aminophenol (pAP) liberated from peptideconjugated pAP (Boc-Leu-Gly-Arg-pAP; LGR-pAP), at the last step of the LAL reaction, was detected with redox cycling within a nanoscale gap using a fabricated device as the second signal amplification. First, an electrochemical immunoassay for goat immunoglobulin G (IgG), used as a model analyte, was performed with an endotoxin-labeled antibody using a 96-well plate. The results indicated that the endotoxin-labeled antibody was usable for immunoassays. However, a high background was observed. To decrease the background and increase the efficiency of the reactions, magnetic beads in an endotoxin-free test tube were used for the immunosorbent assay. After optimization of the condition, goat IgG was successfully detected with single-signal amplification of the cascade reaction at concentrations as low as 10 pg/mL (67 fM) using a Au disc electrode. Finally, an immunoassay for goat IgG on magnetic beads using a redox cycling-inducing device was performed. With the dual-signal amplification strategies of redox cycling within a nanoscale gap and LAL reactions, the detection limit was 70 fg/mL (470 aM). Our highly sensitive and easy-to-use immunoassay strategy provides a platform for clinical diagnosis to detect early-stage infections.
引用
收藏
页码:12393 / 12400
页数:8
相关论文
共 50 条
  • [21] PCR-Free Self-Calibrated Ratiometric Electrochemical Genosensor Utilizing a Dual-Signal Amplification Approach for Genomic Detection of Mycobacterium Tuberculosis
    Bunyarataphan, Sasinee
    Prammananan, Therdsak
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (01)
  • [22] Cascade Dual-Signal Enhancement by Integrating Exonuclease III-Assisted Target-Recycling and Rolling Circle Amplification for Ultrasensitive Electrochemical Detection of DNA
    Zhou, Xingxing
    Guo, Shijing
    Gao, Jiaxi
    Zhao, Jianmin
    Xu, Wenju
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (13) : B603 - B609
  • [23] Electrochemical immunoassay for procalcitonin antigen detection based on signal amplification strategy of multiple nanocomposites
    Fang, Yi-Shan
    Wang, Hai-Ying
    Wang, Li-Shi
    Wang, Ju-Fang
    BIOSENSORS & BIOELECTRONICS, 2014, 51 : 310 - 316
  • [24] Dual-Mode Electrochemical Immunoassay for Insulin Based on Cu7S4-Au as a Double Signal Indicator
    Li, Yueyuan
    Zhu, Wenjuan
    Kang, Qing
    Yang, Lei
    Zhang, Yong
    Wang, Yaoguang
    Wei, Qin
    ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (45) : 38791 - 38798
  • [25] A sensitive determination of albumin in urine by molecularly imprinted electrochemical biosensor based on dual-signal strategy
    Zhang, Guihua
    Yu, Ying
    Guo, Manli
    Lin, Bixia
    Zhang, Li
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 288 : 564 - 570
  • [26] Novel electrochemical aptasensor with dual signal amplification strategy for detection of acetamiprid
    Shi, Xiaojie
    Sun, Jianfei
    Yao, Yao
    Liu, Huimin
    Huang, Jingcheng
    Guo, Yemin
    Sun, Xia
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 705
  • [27] An Online Electrochemical System for Continuous Measurement of Glutamate with Signal Amplification by Enzymatic Substrate Cycling
    Zhang, Zipin
    Xiao, Tongfang
    Hao, Jie
    Yu, Ping
    Ohsaka, Takeo
    Mao, Lanqun
    ELECTROANALYSIS, 2015, 27 (10) : 2406 - 2411
  • [28] Cascade signal amplification strategy by coupling chemical redox-cycling and Fenton-like reaction: Toward an ultrasensitive split-type fluorescent immunoassay
    Chen, Lin-Ge
    Sun, Lu
    Wu, Ning-Ning
    Tao, Bei-Bei
    Wang, Hai-Bo
    ANALYTICA CHIMICA ACTA, 2023, 1279
  • [29] A disposable dual-signal enantioselective electrochemical sensor based on stereogenic porous chiral carbon nanotubes hydrogel
    Yang, Yang
    Li, Meixian
    Zhu, Zhiwei
    TALANTA, 2021, 232
  • [30] Engineering DNAzyme cyclic amplification integrated dual-signal chiral sensing system for specific recognition of histidine enantiomers
    Han, Qian
    Mo, Fangjing
    Wu, Jingling
    Wang, Cun
    Chen, Min
    Fu, Yingzi
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 302