Atrial fibrillation variability on long-term monitoring of implantable cardiac rhythm management devices

被引:2
作者
Kaplan, Rachel M. [1 ]
Ziegler, Paul D. [2 ]
Koehler, Jodi [2 ]
Glotzer, Taya V. [3 ]
Passman, Rod S. [1 ]
机构
[1] Northwestern Univ, Dept Cardiol, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Medtronic Inc, Cardiac Rhythm Dis Management, Minneapolis, MN USA
[3] Hackensack Univ, Dept Cardiol, Med Ctr, Hackensack, NJ USA
关键词
Atrial Fibrillation; Implantable Devices; Natural History; CRYPTOGENIC STROKE; PACEMAKERS; TACHYARRHYTHMIAS; PROGRESSION; ARRHYTHMIAS; STRATEGIES; ACCURACY; SYMPTOMS; INSIGHTS;
D O I
10.1002/clc.22766
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAtrial fibrillation (AF) burden and duration are predictors of thromboembolic events. The random nature of these measures may affect clinical decision making. The objective of this study was to determine temporal changes in AF burden as detected by continuous monitoring. HypothesisAF burden changes over time when detected by continuous monitoring. MethodsA post hoc analysis of patients enrolled in the TRENDS (A Prospective Study of the Clinical Significance of Atrial Arrhythmias Detected by Implanted Device Diagnostics) study with 1 stroke risk factor(s) who were implanted with a dual-chamber cardiac rhythm management device (CRMD) and had AF burden data available for 2 years was performed. AF burden was defined as no AF, low AF (<5.5 hours on any given day), or high AF burden (5.5 hours in a day), and was first assessed over the initial 30 days following enrollment and then reassessed at 6-month intervals for 2 years. ResultsAmong 394 patients included, the average age was 70.2 10.9 years, 71% were male, and mean CHA(2)DS(2-)VASc (congestive heart failure, hypertension, age 75 years, diabetes mellitus, prior stroke or TIA, vascular disease, age 65-74 years, sex category) score was 3.7 +/- 1.6. In the 30-day baseline period, 75.1% of patients had no AF, 11.2% had low AF, and 13.7% had high AF. Over the subsequent 2 years, 40.0% of patients initially classified as no AF or low AF experienced periods with high AF, whereas 59.3% of patients initially classified as high AF experienced 6 consecutive months with no AF or low AF. Advanced age was the sole predictor of AF progression. ConclusionsSignificant temporal variability in AF burden exists when measured continuously with an implantable CRMD.
引用
收藏
页码:1044 / 1048
页数:5
相关论文
共 50 条
  • [41] Alterations in atrial electrogram amplitude as steady sinus rhythm transitions to paroxysmal atrial fibrillation during continuous monitoring in patients with implantable cardiac devices: Insights from the IMPACT study
    Kantharia, Bharat K.
    Lip, Gregory Y. H.
    Martin, David T.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (05) : 1357 - 1363
  • [42] Noninvasive long-term ECG monitoring vs. loop recorder implantation for the atrial fibrillation management
    Mamchur, Sergey E.
    Khomenko, Egor A.
    Chichkova, Tatiana Y.
    Romanova, Maria P.
    Evtushenko, Veronika V.
    Polikutina, Olga M.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2020, 25 (02)
  • [43] Long-term ECG monitoring using an implantable loop recorder for the detection of atrial fibrillation after cavotricuspid isthmus ablation in patients with atrial flutter
    Mittal, Suneet
    Pokushalov, Evgeny
    Romanov, Alexander
    Ferrara, Martha
    Arshad, Aysha
    Musat, Dan
    Preminger, Mark
    Sichrovsky, Tina
    Steinberg, Jonathan S.
    HEART RHYTHM, 2013, 10 (11) : 1598 - 1604
  • [44] Subclinical atrial fibrillation and stroke: insights from continuous monitoring by implanted cardiac electronic devices
    Lau, Chu-Pak
    Siu, Chung-Wah
    Yiu, Kai-Hang
    Lee, Kathy Lai-Fun
    Chan, Yap-Hang
    Tse, Hung-Fat
    EUROPACE, 2015, 17 : 40 - 46
  • [45] Use of Prolonged Cardiac Rhythm Monitoring to Identify Atrial Fibrillation After Cryptogenic Stroke
    Roy, Alexis T.
    Schwamm, Lee H.
    Singhal, Aneesh B.
    CURRENT CARDIOLOGY REPORTS, 2022, 24 (04) : 337 - 346
  • [46] Use of Prolonged Cardiac Rhythm Monitoring to Identify Atrial Fibrillation After Cryptogenic Stroke
    Alexis T. Roy
    Lee H. Schwamm
    Aneesh B. Singhal
    Current Cardiology Reports, 2022, 24 : 337 - 346
  • [47] Autonomous nervous system and cardiac arrhythmias in patients with recurrent atrial fibrillation: long-term electrocardiogram monitoring data
    Vetluzhsky, A. V.
    Fomina, I. G.
    CARDIOVASCULAR THERAPY AND PREVENTION, 2007, 6 (04): : 47 - 51
  • [48] Atrial Fibrillation Burden Reduction From Antiarrhythmic Drugs in Patients With Cardiac Implantable Electronic Devices
    Schwartz, Sarah M.
    Peigh, Graham
    Culler, Kasen
    Mathew, Daniel
    Verma, Rhea
    Lemma, Betelehem
    Passman, Rod S.
    CIRCULATION, 2023, 148
  • [49] Asymptomatic versus symptomatic episodes in patientswith paroxysmal atrial fibrillation via long-term monitoring with implantable loop recorders.
    Simantirakis, E. N.
    Papakonstantinou, P. E.
    Chlouverakis, G. I.
    Kanoupakis, E. M.
    Mavrakis, H. E.
    Kallergis, E. M.
    Arkolaki, E. G.
    Vardas, P. E.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 231 : 125 - 130
  • [50] Long-term follow-up of cardiac rhythm after percutaneous mitral balloon valvotomy - Does atrial fibrillation persist?
    Langerveld, J
    van Hemel, NM
    Kelder, JC
    Ernst, JMPG
    Plokker, HWM
    Jaarsma, W
    EUROPACE, 2003, 5 (01): : 47 - 53