Three-dimensional neuromagnetic recording in the spinal cord

被引:6
作者
Hoshino, Y [1 ]
Kawabata, S [1 ]
Komori, H [1 ]
Ohkubo, H [1 ]
Tomizawa, M [1 ]
Shinomiya, K [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch, Sec Orthoped & spinal Surg, Bunkyo Ku, Tokyo 1138519, Japan
来源
UNVEILING THE MYSTERY OF THE BRAIN: NEUROPHYSIOLOGICAL INVESTIGATION OF THE BRAIN FUNCTION | 2005年 / 1278卷
关键词
neuromagnetic recording; magnetic field; spinal cord evoked potential; spinal cord evoked magnetic field; CONDUCTION BLOCK; VISUALIZATION;
D O I
10.1016/j.ics.2004.11.004
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Recently it has been thought that neuromagnetic recording is expected to be a helpful alternative examination, since it can detect neural conduction by non-invasive skin surface recording. In this study, we recorded three-dimensional spinal cord evoked magnetic fields (SCEFs) in the cervical spinal cord of rabbits, and evaluated their usefulness in the examination of spinal cord function. The rabbits were anesthetized and put on a respirator. Electrical stimuli (10 Hz square wave pulses, 0.03 ms in duration, 8-10 mA in intensity) were applied to the lower thoracic spinal cord with an epidural electrode. SCEFs were recorded at 64-96 measurement points on the skin surface over the cervical spine. In addition, spinal cord evoked potentials (SCEPs) were recorded at the skin surface. The recordings were done before and after the disconnection of the cervical spinal cord. Three-dimensional SCEFs were recorded in all animals and the conducting neuronal activity was visualized by magnetic contour map. The three components of the SCEFs showed characteristic patterns, respectively. The positions of action currents were estimated by dipole localization. Although further studies are necessary, three-dimensional recording of SCEFs could be a helpful method to evaluate the function of the spinal cord. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:309 / 312
页数:4
相关论文
共 4 条
  • [1] Visualization of incomplete conduction block by neuromagnetic recording
    Fukuoka, Y
    Komori, H
    Kawabata, S
    Ohkubo, H
    Shinomiya, K
    [J]. CLINICAL NEUROPHYSIOLOGY, 2004, 115 (09) : 2113 - 2122
  • [2] Imaging of neural conduction block by neuromagnetic recording
    Fukuoka, Y
    Komori, H
    Kawabata, S
    Ohkubo, H
    Shinomiya, K
    Terasaki, O
    [J]. CLINICAL NEUROPHYSIOLOGY, 2002, 113 (12) : 1985 - 1992
  • [3] Visualization of conductive spinal cord activity using a biomagnetometer
    Kawabata, S
    Komori, H
    Mochida, K
    Harunobu, O
    Shinomiya, K
    [J]. SPINE, 2002, 27 (05) : 475 - 479
  • [4] OKUBO H, 2003, J MED DENT SCI, V50, P177