Experimental Parametric Study of a Functional-Magnetic Material Designed for the Monitoring of Corrosion in Reinforced Concrete Structures

被引:1
|
作者
Souriou, David [1 ]
Kadkhodazadeh, Sima [2 ]
Derobert, Xavier [1 ]
Guilbert, David [2 ]
Ihamouten, Amine [1 ]
机构
[1] Univ Gustave Eiffel, Dept Mat & Struct MAST, Lab Modelling Expt & Survey Transport Infrastruct, F-44344 Bouguenais, France
[2] Cerema Quest, Dept Lab Angers DLan, F-49136 Les Ponts De Ce, France
关键词
corrosion; magnetic flux density; non-destructive technique; ferromagnetic materials; chloride ions; Structural Health Monitoring; Civil Engineering; STEEL REINFORCEMENT; SENSOR; SENSITIVITY; MICRO; WATER;
D O I
10.3390/rs14153623
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The presence of aggressive agents (such as chloride ions brought by seawater) in reinforced concrete structures is responsible for the corrosion of the steel rebars. A Structural Health Monitoring technology is developed as a new passive preventive method that would allow for the detection of and for the ability to follow the presence of chloride ions in the cover concrete of reinforced concrete. This technology, referenced as Functional Magnetic Material (FMM), consists on the measurement with an external interrogator of a Magnetic Observable (MO), partially shielded by a patch and corrodible by chloride ions. This paper presents the results of a parametric experimental study, allowing the validation of the concept of this technology, by highlighting the variation of the MO while considering the geometry and the corrosion level of the patch (based on its Relative Mass Loss-RML), as well as the distance between the samples and the interrogator. The results show that the MO of the FMM significantly varies with the increase in the RML of the patch. A 10%-RML for the patch is sufficient for detecting a variation of the MO of the FMM, and the relative variations of the MO are strongly dependent on the distance between the FMM and the magnetometer, as well as the patch's thickness.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] CORROSION MONITORING IN REINFORCED CONCRETE STRUCTURES
    Nygaard, Peter V.
    Klinghoffer, Oskar
    ADVANCES IN CONCRETE STRUCTURAL DURABILITY, PROCEEDINGS OF ICDCS2008, VOLS 1 AND 2, 2008, : 1219 - 1228
  • [2] Monitoring corrosion in reinforced concrete structures
    Kung, Peter
    Comanici, Maria I.
    SENSORS FOR EXTREME HARSH ENVIRONMENTS, 2014, 9113
  • [3] Corrosion monitoring of reinforced concrete structures - A review
    Song, Ha-Won
    Saraswathy, Velu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (01): : 1 - 28
  • [4] Case Study: Corrosion Monitoring of In-Service Reinforced Concrete Structures
    Zafar, Idrees
    Corrosion Management, 2024, (180): : 38 - 41
  • [5] Monitoring Corrosion of Steel Bars in Reinforced Concrete Structures
    Verma, Sanjeev Kumar
    Bhadauria, Sudhir Singh
    Akhtar, Saleem
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [6] Experimental study for seismic retrofit of non-seismic designed reinforced concrete structures
    Park, Tae Won
    Na, Ung Jin
    Chung, Lan
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2011, 20 (02): : 271 - 289
  • [7] Subsequent sensor installation for corrosion monitoring of reinforced concrete structures
    Budelmann, H.
    Dressler, I.
    Wichmann, H. -J.
    LIFE-CYCLE OF ENGINEERING SYSTEMS: EMPHASIS ON SUSTAINABLE CIVIL INFRASTRUCTURE, 2017, : 1242 - 1247
  • [8] Embeddable reference electrodes for corrosion monitoring of reinforced concrete structures
    Duffo, G. S.
    Farina, S. B.
    Giordano, C. M.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2010, 61 (06): : 480 - 489
  • [9] Corrosion Monitoring in Reinforced Concrete - Structures New Research Results
    Fraundorfer, Andreas
    Dauberschmidt, Christoph
    BETON- UND STAHLBETONBAU, 2022, 117 (12) : 956 - 967
  • [10] Permanent corrosion monitoring in new and existing reinforced concrete structures
    Broomfield, JP
    Davies, K
    Hladky, K
    MATERIALS PERFORMANCE, 2000, 39 (07) : 66 - 71