Simultaneous voltammetric detection of ascorbic acid, dopamine and uric acid using a pyrolytic graphite electrode modified into dopamine solution

被引:162
作者
da Silva, Robson P. [1 ]
Lima, Antonio William O. [1 ]
Serrano, Silvia H. P. [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, BR-05513970 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
pyrolytic graphite modified; electrode; uric and ascorbic acids; dopamine; biological fluids; differential pulse voltammetry;
D O I
10.1016/j.aca.2008.02.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pyrolytic graphite electrodes (PGE) were modified into dopamine solutions using phosphate buffer solutions, pH 10 and 6.5, as supporting electrolyte. The modification process involved a previous anodization of the working electrode at +1. 5 V into 0. 1 mol-L-1 NaOH followed by other anodization step, in the same experimental conditions, into dopamine (DA) solutions. pH of the supporting electrolyte performed an important role in the production of a superficial melanin polymeric film, which permitted the simultaneous detection of ascorbic acid (AA), (DA) and uric acid (UA), Delta EAA-DA = 222 mV-, Delta EAA-UA = 360 mV and Delta EDA-UA=138mV, avoiding the superficial poisoning effects. The calculated detection limits were: 1.4 x 10(-6) mol L-1 for uric acid, 1.3x10-(5) molL(-1) for ascorbic acid and 1.1 X 10(-7) mol L-1 for dopamine, with sensitivities of (7.7 +/- 0.5), (0.061 +/- 0.001) and (9.5 +/- 0.05)A mol(-1) cm(-2), respectively, with no mutual interference. Uric acid was determined in urine, blood and serum human samples after dilution in phosphate buffer and no additional sample pre-treatment was necessary. The concentration of uric acid in urine was higher than the values found in blood and serum and the recovery tests (92-102%) indicated that no matrix effects were observed. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 88 条
[1]   PROBING BRAIN CHEMISTRY WITH ELECTROANALYTICAL TECHNIQUES [J].
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1976, 48 (14) :1126-&
[2]   Capability of a carbon-polyvinylchloride composite electrode for the detection of dopamine, ascorbic acid and uric acid [J].
Aguilar, R ;
Dávila, MM ;
Elizalde, MP ;
Mattusch, J ;
Wennrich, R .
ELECTROCHIMICA ACTA, 2004, 49 (06) :851-859
[3]   A sensitive determination of dopamine in the presence of ascorbic acid using a nafion-coated clinoptilolite-modified carbon paste electrode [J].
Alpat, S ;
Alpat, SK ;
Telefoncu, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (04) :695-700
[4]   Electrochemical detection of NADH and dopamine in flow analysis based on tetraruthenated porphyrin modified electrodes [J].
Angnes, L ;
Azevedo, CMN ;
Araki, K ;
Toma, HE .
ANALYTICA CHIMICA ACTA, 1996, 329 (1-2) :91-95
[5]   ELECTROCHEMICAL ACTIVATION OF CARBON ELECTRODES IN BASE - MINIMIZATION OF DOPAMINE ADSORPTION AND ELECTRODE CAPACITANCE [J].
ANJO, DM ;
KAHR, M ;
KHODABAKHSH, MM ;
NOWINSKI, S ;
WANGER, M .
ANALYTICAL CHEMISTRY, 1989, 61 (23) :2603-2608
[6]  
[Anonymous], 1996, Laboratory test handbook
[8]   ELECTROCHEMICAL PRETREATMENT OF CARBON ELECTRODES AS A FUNCTION OF POTENTIAL, PH, AND TIME [J].
BEILBY, AL ;
SASAKI, TA ;
STERN, HM .
ANALYTICAL CHEMISTRY, 1995, 67 (05) :976-980
[9]   OBSERVATION OF KINETIC HETEROGENEITY ON HIGHLY ORDERED PYROLYTIC-GRAPHITE USING ELECTROGENERATED CHEMI-LUMINESCENCE [J].
BOWLING, RJ ;
MCCREERY, RL ;
PHARR, CM ;
ENGSTROM, RC .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2763-2766
[10]   A disposable single-use electrochemical sensor for the detection of uric acid in human whole blood [J].
Chen, JC ;
Chung, HH ;
Hsu, CT ;
Tsai, DM ;
Kumar, AS ;
Zen, JM .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 110 (02) :364-369