3D Microendoscopic Electrical Impedance Tomography for Margin Assessment During Robot-Assisted Laparoscopic Prostatectomy

被引:19
|
作者
Mahara, Aditya [1 ]
Khan, Shadab [1 ]
Murphy, Ethan K. [1 ]
Schned, Alan R. [2 ,3 ]
Hyams, Elias S. [2 ,3 ]
Halter, Ryan J. [1 ,2 ]
机构
[1] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[2] Dartmouth Coll, Geisel Sch Med, Hanover, NH 03755 USA
[3] Dartmouth Hitchcock Med Ctr, Lebanon, NH 03766 USA
关键词
Electrical impedance tomography; microendoscopic probe; prostate cancer; surgical margin assessment; POSITIVE SURGICAL MARGINS; RADICAL PROSTATECTOMY; CAVERNOUS NERVES; EIT; SPECTROSCOPY; SYSTEM; IMAGES; RECONSTRUCTION; ALGORITHMS; ELECTRODES;
D O I
10.1109/TMI.2015.2407833
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Radially configured microendoscopic electrical impedance probes intended for intraoperative surgical margin assessment during robot-assisted laparoscopic prostatectomy (RALP) were examined through simulation, bench-top experimentation, and ex vivo tissue studies. Three probe designs with 8, 9, and 17 electrodes, respectively, were analyzed through finite element method based simulations. One mm diameter spherical inclusions (sigma(inclusion) = 1 S/m) are positioned at various locations within a hemispherical background (sigma(inclusion) = 0.1 S/m) of radius 5 mm. An 8-electrode configuration is not able to localize the inclusion at these positions while 9 and 17-electrode configurations are able to accurately reconstruct the inclusion at maximum depth of 1 mm and 3 mm, respectively. All three probe designs were constructed and evaluated using saline phantoms and ex vivo porcine and human prostate tissues. The 17-electrode probe performed best in saline phantom studies, accurately reconstructing high contrast, 1-mm-diameter metal cylindrical inclusions in a saline bath (sigma(saline) = 0.1 S/m) with a position and area error of 0.46 mm and 0.84 mm(2), respectively. Additionally, the 17-electrode probe was able to adequately distinguish cancerous from benign tissues in three ex vivo human prostates. Simulations, bench-top saline experiments, and ex vivo tissue sampling suggest that for intraoperative surgical margin assessment during RALP, the 17-electrode probe (as compared to an 8 and 9 electrode probe) will be necessary to provide sufficient accuracy and sensitivity.
引用
收藏
页码:1590 / 1601
页数:12
相关论文
共 50 条
  • [21] Individualised positive end-expiratory pressure guided by electrical impedance tomography for robot-assisted laparoscopic radical prostatectomy: a prospective, randomised controlled clinical trial
    Girrbach, Felix
    Petroff, David
    Schulz, Susann
    Hempel, Gunther
    Lange, Mirko
    Klotz, Carolin
    Scherz, Stephanie
    Giannella-Neto, Antonio
    Beda, Alessandro
    Jardim-Neto, Alcendino
    Stolzenburg, Jens-Uwe
    Reske, Andreas W.
    Wrigge, Hermann
    Simon, Philipp
    BRITISH JOURNAL OF ANAESTHESIA, 2020, 125 (03) : 373 - 382
  • [22] Predictors of prolonged operative time during robot-assisted laparoscopic radical prostatectomy
    Yong, Daniel Z.
    Tsivian, Matvey
    Zilberman, Dorit E.
    Ferrandino, Michael N.
    Mouraviev, Vladimir
    Albala, David M.
    BJU INTERNATIONAL, 2011, 107 (02) : 280 - 282
  • [23] Assessment of the viability of transplant organs with 3D electrical impedance tomography
    Edd, Jon F.
    Rubinsky, Boris
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2644 - 2647
  • [24] Robot-Assisted 3D Medical Sonography
    Petrovic, P. B.
    Lukic, N.
    Danilov, I.
    NEW TRENDS IN MEDICAL AND SERVICE ROBOTS: CHALLENGES AND SOLUTIONS, 2014, 20 : 45 - 61
  • [25] Anastomotic Leak After Robot-Assisted Laparoscopic Radical Prostatectomy: Evaluation With MDCT Cystography With Multiplanar Reformatting and 3D Display
    Kawamoto, Satomi
    Allaf, Mohamad
    Corl, Frank M.
    Feng, Tom
    Yohannan, Jithin
    Fishman, Elliot K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : W595 - W601
  • [26] Impact of Median Lobe Anatomy: Does Its Presence Affect Surgical Margin Rates During Robot-Assisted Laparoscopic Prostatectomy?
    Jung, Howard
    Ngor, Eunis
    Slezak, Jeffrey M.
    Chang, Allen
    Chien, Gary W.
    JOURNAL OF ENDOUROLOGY, 2012, 26 (05) : 457 - 460
  • [27] Editorial Comment to Predictors of operative time during radical retropubic prostatectomy and robot-assisted laparoscopic prostatectomy
    Shimbo, Masaki
    INTERNATIONAL JOURNAL OF UROLOGY, 2017, 24 (08) : 624 - 624
  • [28] MICROPOROUS POLYSACCHARIDE HEMOSPHERES AS A TOPICAL HEMOSTATIC DURING ROBOT-ASSISTED LAPAROSCOPIC RADICAL PROSTATECTOMY
    Humphreys, M. R.
    Andrews, P. E.
    JOURNAL OF ENDOUROLOGY, 2010, 24 : A250 - A250
  • [29] Evaluation of the Xanas nasal pulse oximetry sensor during robot-assisted laparoscopic prostatectomy
    Howle, R.
    Follett, T.
    Pathmanahan, A.
    Vasdev, N.
    Gowrie-Mohan, S.
    Columb, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 119 (02) : E26 - E27
  • [30] Hemodynamic Perturbations During Robot-Assisted Laparoscopic Radical Prostatectomy in 45° Trendelenburg Position
    Lestar, Melinda
    Gunnarsson, Lars
    Lagerstrand, Lars
    Wiklund, Peter
    Odeberg-Wernerman, Suzanne
    ANESTHESIA AND ANALGESIA, 2011, 113 (05): : 1069 - 1075