Superharmonic microbubble Doppler effect in ultrasound therapy

被引:16
|
作者
Pouliopoulos, Antonios N. [1 ]
Choi, James J. [1 ]
机构
[1] Imperial Coll London, Dept Bioengn, Noninvas Surg & Biopsy Lab, London SW7 2AZ, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 16期
基金
英国惠康基金;
关键词
Doppler effect; therapeutic ultrasound; acoustic cavitation; microbubble dynamics; BLOOD-BRAIN-BARRIER; REAL-TIME FEEDBACK; CONTRAST AGENTS; RADIATION FORCE; INERTIAL CAVITATION; PULSED ULTRASOUND; IN-VIVO; DRUG; FLOW; OSCILLATIONS;
D O I
10.1088/0031-9155/61/16/6154
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5 x 10(4)-5 x 10(7) microbubbles ml(-1)) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i. e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s(-1), prior to the onset of broadband emissions, which is an indicator for high magnitude inertial cavitation. Although the microbubble redistribution was shown to persist for the entire sonication period in dense populations, it was constrained to the first few milliseconds in lower concentrations. In conclusion, superharmonic microbubble Doppler effects can provide a quantitative measure of effective velocities of a sonicated microbubble population and could be used for monitoring ultrasound therapy in real-time.
引用
收藏
页码:6154 / 6171
页数:18
相关论文
共 50 条
  • [41] Application of ultrasound microbubble contrast technology in ophthalmic targeted therapy: literature analysis
    Yuan, Jia-Ying
    Zhang, Jian-Hua
    Tang, Chong
    Zhu, Hong
    Xie, Hua
    Gao, Shuan-Jie
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2011, 4 (05) : 537 - 542
  • [42] A PVDF Receiver for Acoustic Monitoring of Microbubble-Mediated Ultrasound Brain Therapy
    Lin, Yi
    O'Reilly, Meaghan A.
    Hynynen, Kullervo
    SENSORS, 2023, 23 (03)
  • [43] New Progress in Angiogenesis Therapy of Cardiovascular Disease by Ultrasound Targeted Microbubble Destruction
    Liao, Yang-Ying
    Chen, Zhi-Yi
    Wang, Yi-Xiang
    Lin, Yan
    Yang, Feng
    Zhou, Qiu-Lan
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [44] Microbubble Potentiated ultrasound as a method of stroke therapy in a pig model: Preliminary findings
    Culp, WC
    Erdem, E
    Roberson, PK
    Husain, MM
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (11) : 1433 - 1436
  • [45] Promoting the effect of microbubble-enhanced ultrasound on hyperthermia in rabbit liver
    Yuwen Yang
    Huanqian Luo
    Yang Zhao
    Lu Li
    Yan He
    Fen Xi
    Hai Jin
    Ruru Gao
    Qiong Luo
    Jianhua Liu
    Journal of Medical Ultrasonics, 2022, 49 : 133 - 142
  • [46] Promoting the effect of microbubble-enhanced ultrasound on hyperthermia in rabbit liver
    Yang, Yuwen
    Luo, Huanqian
    Zhao, Yang
    Li, Lu
    He, Yan
    Xi, Fen
    Jin, Hai
    Gao, Ruru
    Luo, Qiong
    Liu, Jianhua
    JOURNAL OF MEDICAL ULTRASONICS, 2022, 49 (02) : 133 - 142
  • [47] The effect of size range on ultrasound-induced translations in microbubble populationsa)
    Supponen, Outi
    Upadhyay, Awaneesh
    Lum, Jordan
    Guidi, Francesco
    Murray, Todd
    Vos, Hendrik J.
    Tortoli, Piero
    Borden, Mark
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2020, 147 (05): : 3236 - 3247
  • [48] EFFECT OF MICROBUBBLE-ENHANCED ULTRASOUND ON RADIOFREQUENCY ABLATION OF RABBIT LIVER
    Chen, Zhong
    Zhao, Hongzhi
    Qiao, Xueyan
    Yi, Cuo
    Gao, Shunji
    Gao, Wenhong
    Liu, Zheng
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (07): : 1451 - 1459
  • [49] A COMPARISON OF ULTRASOUND EXPOSURE IN THERAPY AND PULSED DOPPLER FIELDS
    STARRITT, HC
    DUCK, FA
    BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (775): : 557 - 563
  • [50] QUANTITATIVE ULTRASOUND FOR THE MONITORING OF NOVEL MICROBUBBLE AND ULTRASOUND RADIOSENSITIZATION
    Lee, Justin
    Karshafian, Raffi
    Papanicolau, Naum
    Giles, Anoja
    Kolios, Michael C.
    Czarnota, Gregory J.