Superharmonic microbubble Doppler effect in ultrasound therapy

被引:16
|
作者
Pouliopoulos, Antonios N. [1 ]
Choi, James J. [1 ]
机构
[1] Imperial Coll London, Dept Bioengn, Noninvas Surg & Biopsy Lab, London SW7 2AZ, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 16期
基金
英国惠康基金;
关键词
Doppler effect; therapeutic ultrasound; acoustic cavitation; microbubble dynamics; BLOOD-BRAIN-BARRIER; REAL-TIME FEEDBACK; CONTRAST AGENTS; RADIATION FORCE; INERTIAL CAVITATION; PULSED ULTRASOUND; IN-VIVO; DRUG; FLOW; OSCILLATIONS;
D O I
10.1088/0031-9155/61/16/6154
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5 x 10(4)-5 x 10(7) microbubbles ml(-1)) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i. e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s(-1), prior to the onset of broadband emissions, which is an indicator for high magnitude inertial cavitation. Although the microbubble redistribution was shown to persist for the entire sonication period in dense populations, it was constrained to the first few milliseconds in lower concentrations. In conclusion, superharmonic microbubble Doppler effects can provide a quantitative measure of effective velocities of a sonicated microbubble population and could be used for monitoring ultrasound therapy in real-time.
引用
收藏
页码:6154 / 6171
页数:18
相关论文
共 50 条
  • [21] Advances in Ultrasound Mediated Gene Therapy Using Microbubble Contrast Agents
    Sirsi, Shashank R.
    Borden, Mark A.
    THERANOSTICS, 2012, 2 (12): : 1208 - 1222
  • [22] Apoptosis Induction by Ultrasound and Microbubble Mediated Drug Delivery and Gene Therapy
    Chen, Z. -Y.
    Wang, Y. -X.
    Zhao, Y. -Z.
    Yang, F.
    Liu, J. -B.
    Lin, Y.
    Liao, J. -Y.
    Liao, Y. -Y.
    Zhou, Q. -L.
    CURRENT MOLECULAR MEDICINE, 2014, 14 (06) : 723 - 736
  • [23] Ultrasound microbubble contrast agents: Application to therapy for peripheral vascular disease
    Hu, Yi-zhou
    Zhu, Jia-an
    Jiang, Ye-ging
    Hu, Bing
    ADVANCES IN THERAPY, 2009, 26 (04) : 425 - 434
  • [24] Ultrasound microbubble contrast agents: Application to therapy for peripheral vascular disease
    Yi-zhou Hu
    Jia-an Zhu
    Ye-ging Jiang
    Bing Hu
    Advances in Therapy, 2009, 26 : 425 - 434
  • [25] Microbubble contrast agent for color Doppler US: Effect on breast masses
    Kedar, RP
    Cosgrove, D
    McCready, VR
    Bamber, JC
    Carter, ER
    RADIOLOGY, 1996, 198 (03) : 679 - 686
  • [26] Ultrasound-Targeted Microbubble Destruction to Deliver siRNA Cancer Therapy
    Carson, Andrew R.
    McTiernan, Charles F.
    Lavery, Linda
    Grata, Michelle
    Leng, Xiaoping
    Wang, Jianjun
    Chen, Xucai
    Villanueva, Flordeliza S.
    CANCER RESEARCH, 2012, 72 (23) : 6191 - 6199
  • [27] Microbubble Delivery Platform for Ultrasound-Mediated Therapy in Brain Cancers
    Kim, Kibeom
    Lee, Jungmin
    Park, Myoung-Hwan
    PHARMACEUTICS, 2023, 15 (02)
  • [28] GENE THERAPY OF CARCINOMA USING ULTRASOUND-TARGETED MICROBUBBLE DESTRUCTION
    Carson, Andrew R.
    McTiernan, Charles F.
    Lavery, Linda
    Hodnick, Abigail
    Grata, Michelle
    Leng, Xiaoping
    Wang, Jianjun
    Chen, Xucai
    Modzelewski, Ruth A.
    Villanueva, Flordeliza S.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (03): : 393 - 402
  • [29] Ultrasound microbubble potentiated enhancement of hyperthermia-effect in tumours
    Sharma, Deepa
    Giles, Anoja
    Hashim, Amr
    Yip, Jodi
    Ji, Yipeng
    Do, Natalie Ngoc Anh
    Sebastiani, Juliana
    Tran, William Tyler
    Farhat, Golnaz
    Oelze, Michael
    Czarnota, Gregory J.
    PLOS ONE, 2019, 14 (12):
  • [30] Pulse inversion Doppler: A new ultrasound technique for nonlinear imaging of microbubble contrast agents and tissue
    Burns, PN