Superharmonic microbubble Doppler effect in ultrasound therapy

被引:16
作者
Pouliopoulos, Antonios N. [1 ]
Choi, James J. [1 ]
机构
[1] Imperial Coll London, Dept Bioengn, Noninvas Surg & Biopsy Lab, London SW7 2AZ, England
基金
英国惠康基金;
关键词
Doppler effect; therapeutic ultrasound; acoustic cavitation; microbubble dynamics; BLOOD-BRAIN-BARRIER; REAL-TIME FEEDBACK; CONTRAST AGENTS; RADIATION FORCE; INERTIAL CAVITATION; PULSED ULTRASOUND; IN-VIVO; DRUG; FLOW; OSCILLATIONS;
D O I
10.1088/0031-9155/61/16/6154
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5 x 10(4)-5 x 10(7) microbubbles ml(-1)) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i. e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s(-1), prior to the onset of broadband emissions, which is an indicator for high magnitude inertial cavitation. Although the microbubble redistribution was shown to persist for the entire sonication period in dense populations, it was constrained to the first few milliseconds in lower concentrations. In conclusion, superharmonic microbubble Doppler effects can provide a quantitative measure of effective velocities of a sonicated microbubble population and could be used for monitoring ultrasound therapy in real-time.
引用
收藏
页码:6154 / 6171
页数:18
相关论文
共 57 条
[1]   THE EFFECT OF SHORT DURATION ULTRASOUND PULSES ON THE INTERACTION BETWEEN INDIVIDUAL MICROBUBBLES AND FIBRIN CLOTS [J].
Acconcia, Christopher ;
Leung, Ben Y. C. ;
Manjunath, Anoop ;
Goertz, David E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (10) :2774-2782
[2]   INTERACTIONS BETWEEN INDIVIDUAL ULTRASOUND-STIMULATED MICROBUBBLES AND FIBRIN CLOTS [J].
Acconcia, Christopher ;
Leung, Ben Y. C. ;
Manjunath, Anoop ;
Goertz, David E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (09) :2134-2150
[3]   Interactions between ultrasound stimulated microbubbles and fibrin clots [J].
Acconcia, Christopher ;
Leung, Ben Y. C. ;
Hynynen, Kullervo ;
Goertz, David E. .
APPLIED PHYSICS LETTERS, 2013, 103 (05)
[4]  
[Anonymous], 1906, Fields of Force
[5]   Sonic effervescence: A tutorial on acoustic cavitation [J].
Apfel, RE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (03) :1227-1237
[7]   GAUGING THE LIKELIHOOD OF CAVITATION FROM SHORT-PULSE, LOW-DUTY CYCLE DIAGNOSTIC ULTRASOUND [J].
APFEL, RE ;
HOLLAND, CK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :179-185
[8]   SHAKEN AND STIRRED: MECHANISMS OF ULTRASOUND-ENHANCED THROMBOLYSIS [J].
Bader, Kenneth B. ;
Gruber, Matthew J. ;
Holland, Christy K. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (01) :187-196
[9]   Vascular flow and perfusion imaging with ultrasound contrast agents [J].
Bruce, M ;
Averkiou, M ;
Tiemann, K ;
Lohmaier, S ;
Powers, J ;
Beach, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (06) :735-743
[10]   The pulse length-dependence of inertial cavitation dose and hemolysis [J].
Chen, WS ;
Brayman, AA ;
Matula, TJ ;
Crum, LA ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (05) :739-748