Background D-dimer antigen is a heterogeneous mixture of fibrin degradation products that when present at high levels in plasma indicate ongoing coagulation and fibrinolysis. The heterogeneous nature of the target D-dimer antigen and the variety of assay systems means that it is difficult to compare results from different methods. Objectives To identify a universally agreed D-dimer standard that could help harmonize results from different methods. Methods A pool of patient plasma with high D-dimer levels was freeze-dried and investigated as a long-term World Health Organization international standard for D-dimer. Fibrin degradation products from clot lysis reactions were also freeze-dried in various formulations and investigated in commutability studies with patient plasma. Results Problems of instability of D-dimer plasma emerged suggesting loss of reactivity after freeze-drying and storage at -20 degrees C of 10%-18% per year. Freeze-dried fibrin degradation products added to plasma were also unstable, but the sugar trehalose was found to improve stability. However, this preparation was not suitable as a standard in widely used assay platforms. Previous studies suggest fibrin degradation products are prone to structural rearrangements and amyloid formation, which may explain the instability of candidate D-dimer standards. Conclusions The known difficulties of D-dimer standardization are compounded by instability of D-dimer antigen after freeze-drying, described in this report. Fibrin degradation products added to plasma and stabilized by trehalose are not suitable as a standard for D-dimer measurement harmonization. Trehalose stabilization of pooled patient plasma containing high D-dimer levels may produce a useful standard, but this requires confirmation.
引用
收藏
页码:498 / 507
页数:10
相关论文
共 45 条
[41]   The molecular weights, mass distribution, chain composition, and structure of soluble fibrin degradation products released from a fibrin clot perfused with plasmin [J].
Walker, JB ;
Nesheim, ME .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1999, 274 (08) :5201-5212
[42]  
Weisel JW, 1999, THROMB HAEMOSTASIS, V82, P277
[43]   IDENTIFICATION OF D-DIMER-E COMPLEX IN DISSEMINATED INTRAVASCULAR COAGULATION [J].
WHITAKER, AN ;
ROWE, EA ;
MASCI, PP ;
GAFFNEY, PJ .
THROMBOSIS RESEARCH, 1980, 18 (3-4) :453-459
[44]   Evaluation of variation in D-dimer levels among COVID-19 and bacterial pneumonia: a retrospective analysis [J].
Yu, Bilian ;
Li, Xin ;
Chen, Jin ;
Ouyang, Mingqi ;
Zhang, Hong ;
Zhao, Xinge ;
Tang, Liang ;
Luo, Qin ;
Xu, Min ;
Yang, Lizhen ;
Huang, Guxiang ;
Liu, Xianling ;
Tang, Jianjun .
JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2020, 50 (03) :548-557
[45]   D-dimer levels on admission to predict in-hospital mortality in patients with Covid-19 [J].
Zhang, Litao ;
Yan, Xinsheng ;
Fan, Qingkun ;
Liu, Haiyan ;
Liu, Xintian ;
Liu, Zejin ;
Zhang, Zhenlu .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2020, 18 (06) :1324-1329