A systematic review on parametric dependencies of transpired solar collector performance

被引:10
作者
Bake, Maitiniyazi [1 ]
Shukla, Ashish [1 ]
Liu, Shuli [1 ]
Agrawal, Avlokita [2 ]
机构
[1] Coventry Univ, Fac Engn Environm & Comp, Sch Energy Construct & Environm, Coventry CV1 2HF, W Midlands, England
[2] Indian Inst Technol, Dept Architecture & Planning, Roorkee 247667, Uttrakhand, India
基金
英国工程与自然科学研究理事会;
关键词
energy performance; parametric dependency; transpired solar collector; THERMAL-ENERGY STORAGE; HEAT-TRANSFER ANALYSIS; AIR-FLOW; NUMERICAL-SIMULATION; BUILDINGS; DESIGN; ART; OPTIMIZATION; VENTILATION; PROTOTYPE;
D O I
10.1002/er.4200
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Zero or low-carbon buildings can be achieved through novel technology solutions and integrating renewable energy into the buildings. One method of reducing the fossil fuel dependency of buildings and limiting greenhouse gas emissions is integrating the solar thermal system into the built environment. Recently, transpired solar collector has been identified as 1 of the most efficient solar thermal conversion technologies where a very high efficiency can be achieved. The proposed review paper investigates the performance of transpired solar collectors (TSCs) and discusses the relevant case studies in this context. This paper introduces the background and concept of TSCs. It mainly focuses on the study of parametric dependency of the performance of TSCs. The paper also investigates various mathematical models, experimental study, and numerical simulations particularly CFD used for TSC performance analysis. This proposed paper concluded that wind speed and airflow rate are the most dominant factor in TSC performance but solar irradiation, hole diameter, hole geometry, and pitch size have limited effect on TSC performance; also, profile with longer pitch tends to lower the collector efficiency and heat transfer coefficient. However, profile with shorter pitch tends to reduce the wind effect.
引用
收藏
页码:86 / 112
页数:27
相关论文
共 95 条
[1]  
Abulkhair Hani, 2005, INVESTIGATION WIND H
[2]   Performance of a building integrated photovoltaic/thermal (BIPVT) solar collector [J].
Anderson, T. N. ;
Duke, M. ;
Morrison, G. L. ;
Carson, J. K. .
SOLAR ENERGY, 2009, 83 (04) :445-455
[3]  
[Anonymous], ACEE SUMMER STUDY
[4]   A CFD heat transfer analysis of the transpired solar collector under no-wind conditions [J].
Arulanandam, SJ ;
Hollands, KGT ;
Brundrett, E .
SOLAR ENERGY, 1999, 67 (1-3) :93-100
[5]   An experimental investigation of a two-dimensional prototype of a transparent transpired collector [J].
Badache, Messaoud ;
Halle, Stephane ;
Rousse, Daniel R. ;
Quesada, Guillermo ;
Dutil, Yvan .
ENERGY AND BUILDINGS, 2014, 68 :232-241
[6]   Experimental and two-dimensional numerical simulation of an unglazed transpired solar air collector [J].
Badache, Messaoud ;
Rousse, Daniel ;
Halle, Stephane ;
Quesada, Guillermo ;
Dutil, Yvan .
1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 :19-28
[7]   Experimental and numerical simulation of a two-dimensional unglazed transpired solar air collector [J].
Badache, Messaoud ;
Rousse, Daniel R. ;
Halle, Stephane ;
Quesada, Guillermo .
SOLAR ENERGY, 2013, 93 :209-219
[8]   A full 34 factorial experimental design for efficiency optimization of an unglazed transpired solar collector prototype [J].
Badache, Messaoud ;
Halle, Stephane ;
Rousse, Daniel .
SOLAR ENERGY, 2012, 86 (09) :2802-2810
[9]  
Bambara J, 2011, ASHRAE TRAN, V117, P403
[10]   Assessment of the possibility of unglazed transpired type solar collector to be used for drying purposes: a comparative assessment of efficiency of unglazed transpired type solar collector with glazed type solar collector [J].
Bandara, W. B. M. A. C. ;
Amarasekara, B. K. ;
Rupasinghe, C. P. .
7TH INTERNATIONAL CONFERENCE ON BUILDING RESILIENCE: USING SCIENTIFIC KNOWLEDGE TO INFORM POLICY AND PRACTICE IN DISASTER RISK REDUCTION, 2018, 212 :1295-1302