Comparison of Turbo Flash and dual-energy modes of third-generation dual-source CT in pre-transplant renal angiography: a prospective observational study

被引:0
作者
Christopher, Navya [1 ]
Periaswamy, Gopinath [1 ]
Arunachalam, Venkatesh Kasi [1 ]
Pilli, Vandana [1 ]
Renganathan, Rupa [1 ]
Rajasekaran, Sriman [1 ]
Mehta, Pankaj [1 ]
Cherian, Mathew [1 ]
机构
[1] Kovai Med Ctr & Hosp KMCH, Dept Radiol, Avanashi Rd, Coimbatore 641014, Tamil Nadu, India
关键词
TurboFlash CT; Dual-energy CT; CT renal angiography; IMAGE QUALITY; RISK;
D O I
10.1186/s43055-022-00876-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The purpose of this study was to compare the Image Quality, Contrast Medium Volume, and Radiation dose in renal angiography performed using Turbo Flash mode and dual-energy (DE) mode in the third-generation dual-source dual-energy CT. This prospective observational study was performed on renal donors who underwent CTA imaging as a pre-transplant workup. The study population was divided into two groups. Group A underwent DECT renal angiography. Group B underwent Turbo Flash Mode CT renal angiography. For group A, a contrast volume of 1 ml/kg and for group B at 0.5 ml/kg was administered. Image Quality was evaluated objectively by calculating CNR and SNR and subjectively by a 5-point scale. Radiation Dose analysis was done by noting CTDIvol and DLP on the scanner system and calculating effective radiation dose (ED). Results: The subjective image quality scores for the Turbo Flash group were comparable with the DE group in qualitative image analysis. Additionally, in the Turbo Flash group, there was a reduction in contrast media and effective radiation dose by 47.5% and 32.7%, respectively. Nevertheless, mean attenuation of the abdominal arteries, CNR, SNR, and Noise (S.D) showed statistical significance between the two groups (p value < 0.01). Conclusions: To our knowledge, no previous study compared Turboflash mode with DE protocol in CT renal angiography in a donor group of patients. Turbo Flash CT is an excellent modality that is faster and has an added advantage of decreased radiation dose and contrast media volume reduction, which can be recommended for screening of voluntary kidney donors but needs further clinical studies, validation, and standardization with tailored protocols.
引用
收藏
页数:8
相关论文
共 23 条
[1]   Influence of slice thickness and reconstruction kernel on the computed tomographic attenuation of coronary atherosclerotic plaque [J].
Achenbach, Stephan ;
Boehmer, Kerstin ;
Pflederer, Tobias ;
Ropers, Dieter ;
Seltmann, Martin ;
Lell, Michael ;
Anders, Katharina ;
Kuettner, Axel ;
Uder, Michael ;
Daniel, Werner G. ;
Marwan, Mohamed .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2010, 4 (02) :110-115
[2]  
[Anonymous], which the slaves who risked torture and death to escape North
[3]   Global, regional, and national burden of chronic kidney disease, 1990-2017: a systematic analysis for the Global Burden of Disease Study 2017 [J].
Bikbov, Boris ;
Purcell, Carrie ;
Levey, Andrew S. ;
Smith, Mari ;
Abdoli, Amir ;
Abebe, Molla ;
Adebayo, Oladimeji M. ;
Afarideh, Mohsen ;
Agarwal, Sanjay Kumar ;
Agudelo-Botero, Marcela ;
Ahmadian, Elham ;
Al-Aly, Ziyad ;
Alipour, Vahid ;
Almasi-Hashiani, Amir ;
Al-Raddadi, Rajaa M. ;
Alvis-Guzman, Nelson ;
Amini, Saeed ;
Andrei, Tudorel ;
Andrei, Catalina Liliana ;
Andualem, Zewudu ;
Anjomshoa, Mina ;
Arabloo, Jalal ;
Ashagre, Alebachew Fasil ;
Asmelash, Daniel ;
Ataro, Zerihun ;
Atout, Maha Moh'd Wahbi ;
Ayanore, Martin Amogre ;
Badawi, Alaa ;
Bakhtiari, Ahad ;
Ballew, Shoshana H. ;
Balouchi, Abbas ;
Banach, Maciej ;
Barquera, Simon ;
Basu, Sanjay ;
Bayih, Mulat Tirfie ;
Bedi, Neeraj ;
Bello, Aminu K. ;
Bensenor, Isabela M. ;
Bijani, Ali ;
Boloor, Archith ;
Borzi, Antonio M. ;
Camera, Luis Alberto ;
Carrero, Juan J. ;
Carvalho, Felix ;
Castro, Franz ;
Catala-Lopez, Ferran ;
Chang, Alex R. ;
Chin, Ken Lee ;
Chung, Sheng-Chia ;
Cirillo, Massimo .
LANCET, 2020, 395 (10225) :709-733
[4]   Estimating Effective Dose for CT Using Dose-Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning [J].
Christner, Jodie A. ;
Kofler, James M. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :881-889
[5]   CT Angiography in Potential Living Kidney Donors: 80 kVp Versus 120 kVp [J].
Davarpanah, Amir H. ;
Pahade, Jay K. ;
Cornfeld, Dan ;
Ghita, Monica ;
Kulkarni, Sanjay ;
Israel, Gary M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (05) :W753-W760
[6]   Contrast Material-induced Nephrotoxicity and Intravenous Low-Osmolality Iodinated Contrast Material: Risk Stratification by Using Estimated Glomerular Filtration Rate [J].
Davenport, Matthew S. ;
Khalatbari, Shokoufeh ;
Cohan, Richard H. ;
Dillman, Jonathan R. ;
Myles, James D. ;
Ellis, James H. .
RADIOLOGY, 2013, 268 (03) :719-728
[7]  
Feigal David W Jr, 2002, Int J Trauma Nurs, V8, P1, DOI 10.1067/mtn.2002.121511
[8]   Optimal Vascular and Parenchymal Contrast Enhancement: The Current State of the Art [J].
Fleischmann, Dominik ;
Kamaya, Aya .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) :13-+
[9]   Mortality associated with nephropathy after radiographic contrast exposure [J].
From, Aaron M. ;
Bartholmai, Brian J. ;
Williams, Amy W. ;
Cha, Stephen S. ;
Mcdonald, Furman S. .
MAYO CLINIC PROCEEDINGS, 2008, 83 (10) :1095-1100
[10]   The Global Role of Kidney Transplantation [J].
Garcia, Guillermo Garcia ;
Harden, Paul ;
Chapman, Jeremy .
KIDNEY & BLOOD PRESSURE RESEARCH, 2012, 35 (05) :299-304