A low-cost, scalable, current-sensing digital headstage for high channel count μECoG

被引:11
|
作者
Trumpis, Michael [1 ,2 ]
Insanally, Michele [3 ,4 ]
Zou, Jialin [2 ]
Elsharif, Ashraf [2 ]
Ghomashchi, Ali [2 ]
Artan, N. Sertac [2 ,5 ]
Froemke, Robert C. [3 ,4 ]
Viventi, Jonathan [1 ,2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[2] NYU, Dept Elect & Comp Engn, Tandon Sch Engn, Brooklyn, NY 10003 USA
[3] NYU, Sch Med, Dept Otolaryngol, Skirball Inst Biomol Med,Neurosci Inst,Neurosci &, New York, NY USA
[4] NYU, Ctr Neural Sci, New York, NY 10003 USA
[5] New York Inst Technol, Dept Elect & Comp Engn, New York, NY USA
基金
美国国家科学基金会;
关键词
mu ECoG; transimpedance amplifier; electrocorticography; neural interfaces; digital headstage; LOCAL-FIELD POTENTIALS; BRAIN ACTIVITY; ELECTRODE ARRAY; RECORDINGS; SYSTEM; NOISE; ELECTROPHYSIOLOGY; RADIOGRAPHY; ACTIVATION; CIRCUITS;
D O I
10.1088/1741-2552/aa5a82
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. High channel count electrode arrays allow for the monitoring of large-scale neural activity at high spatial resolution. Implantable arrays featuring many recording sites require compact, high bandwidth front-end electronics. In the present study, we investigated the use of a small, light weight, and low cost digital current-sensing integrated circuit for acquiring cortical surface signals from a 61-channel micro-electrocorticographic (mu ECoG) array. Approach. We recorded both acute and chronic mu ECoG signal from rat auditory cortex using our novel digital current-sensing headstage. For direct comparison, separate recordings were made in the same anesthetized preparations using an analog voltage headstage. A model of electrode impedance explained the transformation between current-and voltage-sensed signals, and was used to reconstruct cortical potential. We evaluated the digital headstage using several metrics of the baseline and response signals. Main results. The digital current headstage recorded neural signal with similar spatiotemporal statistics and auditory frequency tuning compared to the voltage signal. The signal-to-noise ratio of auditory evoked responses (AERs) was significantly stronger in the current signal. Stimulus decoding based on true and reconstructed voltage signals were not significantly different. Recordings from an implanted system showed AERs that were detectable and decodable for 52 d. The reconstruction filter mitigated the thermal current noise of the electrode impedance and enhanced overall SNR. Significance. We developed and validated a novel approach to headstage acquisition that used current-input circuits to independently digitize 61 channels of mu ECoG measurements of the cortical field. These low-cost circuits, intended to measure photo-currents in digital imaging, not only provided a signal representing the local cortical field with virtually the same sensitivity and specificity as a traditional voltage headstage but also resulted in a small, light headstage that can easily be scaled to record from hundreds of channels.
引用
收藏
页数:15
相关论文
共 6 条
  • [1] A Low-cost, 61-channel μECoG Array for use in Rodents
    Woods, Virginia
    Wang, Charles
    Bossi, Silvia
    Insanally, Michele
    Trumpis, Michael
    Froemke, Robert
    Viventi, Jonathan
    2015 7TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2015, : 573 - 576
  • [2] A low-cost, multiplexed μECoG system for high-density recordings in freely moving rodents
    Insanally, Michele
    Trumpis, Michael
    Wang, Charles
    Chiang, Chia-Han
    Woods, Virginia
    Palopoli-Trojani, Kay
    Bossi, Silvia
    Froemke, Robert C.
    Viventi, Jonathan
    JOURNAL OF NEURAL ENGINEERING, 2016, 13 (02)
  • [3] Compact and Low Power Analog Front End with in-situ Data Decimator for High-Channel-Count ECoG Recording
    Ashoori, Ehsan
    Davila-Montero, Sylmarie
    Mason, Andrew J.
    2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2018,
  • [4] Digital versatile disc bipolar electrode: A fast and low-cost approach for visual sensing of analytes and electrocatalysts screening
    Shayan, Mohsen
    Kiani, Abolfazl
    ANALYTICA CHIMICA ACTA, 2015, 888 : 52 - 58
  • [5] All Digital Low-Cost Built-in Defect Testing Strategy for Operational Amplifiers with High Coverage
    Sekyere, Michael
    Saikiran, Marampally
    Chen, Degang
    2022 IEEE 28TH INTERNATIONAL SYMPOSIUM ON ON-LINE TESTING AND ROBUST SYSTEM DESIGN (IOLTS 2022), 2022,
  • [6] A self-calibration method with high-accuracy and low-cost for large-area motion stage based on digital grating projection mode
    Huang, Shengzhou
    Li, Mujun
    Wang, Lei
    Su, Yongsheng
    Liang, Yi
    APPLIED PHYSICS EXPRESS, 2019, 12 (12)