Modern trabecular metal-backed glenoid components in total shoulder arthroplasty: What is the evidence? A systematic review

被引:3
|
作者
Malahias, Michael-Alexander [1 ]
Chytas, Dimitrios [2 ]
Kostretzis, Lazaros [3 ]
Trellopoulos, Angelos [1 ]
Brilakis, Emmanouil [1 ]
Antonogiannakis, Emmanouil [1 ]
机构
[1] Hygeia Hosp, Orthopaed Dept 3, Athens, Greece
[2] Natl & Kapodistrian Univ Athens, Sch Med, Orthopaed Dept 2, Athens, Greece
[3] ATOS Klin, HKF Zentrum, Heidelberg, Germany
关键词
Highly porous glenoid; metal-backed glenoid component; systematic review; tantalum glenoid; total shoulder arthroplasty; trabecular metal glenoid; FOLLOW-UP; BONE INGROWTH; OUTCOMES; ARTHRITIS; FIXATION; FAILURE;
D O I
10.1177/1758573220914277
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundL: A number of papers have been published reporting on the clinical performance of modern trabecular metal-backed glenoid components in total shoulder arthroplasty. However, no systematic review of the literature has been published to date. Methods: The US National Library of Medicine (PubMed/MEDLINE), and the Cochrane Database of Systematic Reviews and EMBASE were queried for publications from January 1980 to October 2019 utilizing keywords pertinent to total shoulder arthroplasty, trabecular metal, and clinical outcomes. Results: Overall, seven articles were included for analysis (322 operated shoulders, mean follow-up range: 2-4 years). The survival rate of modern trabecular metal-backed glenoid components was 96% (309 out of 322 cases) at 43 months mean follow-up, while the rate of aseptic loosening was 0.3% (1 out of 322 cases). There were 35 cases (10.9%) with glenoid component radiolucency (one of them required revision), and 37 cases (11.5%) of metal debris formation, with four of them undergoing revision. Conclusions: There was low quality evidence to show that the use of modern trabecular metal-backed glenoid components in total shoulder arthroplasty may be safe and effective at short-term follow-up. However, this analysis showed alarmingly high rates of both radiolucency of the glenoid component and metal debris formation which raise concern for potential failure of this glenoid component in the long term. Therefore, we feel that modern trabecular metal-backed glenoid components should be still used with caution as part of a structured surveillance or research program until we know if there is a detriment to the prosthesis in the medium to long term. Level: Systematic review, IV.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 50 条
  • [1] Outcomes of Trabecular Metal-backed glenoid components in anatomic total shoulder arthroplasty
    Watson, Scott T.
    Gudger, Garland K., Jr.
    Long, Catherine D.
    Tokish, John M.
    Tolan, Stefan J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (03) : 493 - 498
  • [2] Do Modern Designs of Metal-Backed Glenoid Components Show Improved Clinical Results in Total Shoulder Arthroplasty? A Systematic Review of the Literature
    Kim, Dong Min
    Alabdullatif, Fahad
    Aldeghaither, Mohammed
    Shin, Myung Jin
    Kim, Hyojune
    Park, Dongjun
    Kholinne, Erica
    Jeon, In-Ho
    Koh, Kyoung Hwan
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (09)
  • [3] Evaluation of clinical and radiographic outcomes after total shoulder arthroplasty with inset Trabecular Metal-backed glenoid
    Murphy, Jordan
    Todd, Evan
    Wright, Melissa A.
    Murthi, Anand M.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (05) : 971 - 977
  • [4] Management of failed metal-backed glenoid component in patients with bilateral total shoulder arthroplasty
    Li, Xinning
    Eichinger, Josef K.
    Higgins, Laurence D.
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2013, 7 (04): : 143 - 148
  • [5] Loosening and revision rates after total shoulder arthroplasty: a systematic review of cemented all-polyethylene glenoid and three modern designs of metal-backed glenoid
    Kim, Dong Min
    Aldeghaither, Mohammed
    Alabdullatif, Fahad
    Shin, Myung Jin
    Kholinne, Erica
    Kim, Hyojune
    Jeon, In-Ho
    Koh, Kyoung-Hwan
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [6] Catastrophic failure of a low profile metal-backed glenoid component after total shoulder arthroplasty
    Vuillermin, Carley B.
    Trump, Mark E.
    Barwood, Shane A.
    Hoy, Gregory A.
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2015, 9 (04): : 121 - 127
  • [7] Anatomical total shoulder arthroplasty in young patients with osteoarthritis ALL-POLYETHYLENE VERSUS METAL-BACKED GLENOID
    Gauci, M. O.
    Bonnevialle, N.
    Moineau, G.
    Baba, M.
    Walch, G.
    Boileau, P.
    BONE & JOINT JOURNAL, 2018, 100B (04) : 485 - 492
  • [8] Total shoulder arthroplasty with an uncemented soft-metal-backed glenoid component
    Fucentese, Sandro F.
    Costouros, John G.
    Kuehnel, Stefanie-Peggy
    Gerber, Christian
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (04) : 624 - 631
  • [9] Radiographic and clinical outcomes of second generation Trabecular Metal™ glenoid components in total shoulder arthroplasty
    Chen, Raymond E.
    Brown, Alexander M.
    Greenstein, Alexander S.
    Mannava, Sandeep
    Voloshin, Ilya
    SHOULDER & ELBOW, 2021, 13 (04) : 416 - 425
  • [10] Medium-term rates of radiolucency after primary total shoulder arthroplasty using a cementless metal-backed pegged polyethylene glenoid
    Murray, Nicholas J.
    Al-Hourani, Khalid
    Crowther, Mark A. A.
    Sarangi, Partha P.
    McCann, Philip A.
    SHOULDER & ELBOW, 2021, 13 (03) : 283 - 289