Effect of different anesthetic agents on left ventricular systolic function assessed by echocardiography in hamsters

被引:2
作者
Tanaka, D. M. [1 ]
Romano, M. M. D. [1 ]
Carvalho, E. E. V. [1 ]
Oliveira, L. F. L. [1 ]
Souza, H. C. D. [2 ]
Maciel, B. C. [1 ]
Salgado, H. C. [3 ]
Fazan-Junior, R. [3 ]
Simoes, M. V. [1 ]
机构
[1] Univ Sao Paulo, Fac Med Ribeirao Preto, Dept Med Interna, Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Fac Med Ribeirao Preto, Dept Biomecan Med & Reabilitacao Aparelho Locomot, Ribeirao Preto, SP, Brazil
[3] Univ Sao Paulo, Fac Med Ribeirao Preto, Dept Fisiol, Ribeirao Preto, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Echocardiography; Anesthetics; Systolic function; Hamsters; MURINE CARDIAC-FUNCTION; MICE; ISOFLURANE; KETAMINE; HALOTHANE; DISEASE; STATE; CARDIOMYOPATHY; XYLAZINE; REGIMEN;
D O I
10.1590/1414-431X20165294
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Determination of left ventricular ejection fraction (LVEF) using in vivo imaging is the cardiac functional parameter most frequently employed in preclinical research. However, there is considerable conflict regarding the effects of anesthetic agents on LVEF. This study aimed at assessing the effects of various anesthetic agents on LVEF in hamsters using transthoracic echocardiography. Twelve female hamsters were submitted to echocardiography imaging separated by 1-week intervals under the following conditions: 1) conscious animals, 2) animals anesthetized with isoflurane (inhaled ISO, 3 L/min), 3) animals anesthetized with thiopental (TP, 50 mg/kg, intraperitoneal), and 4) animals anesthetized with 100 mg/kg ketamine plus 10 mg/kg xylazine injected intramuscularly (K/X). LVEF obtained under the effect of anesthetics (ISO=62.2 +/- 3.1%, TP=66.2 +/- 2.7% and K/X=75.8 +/- 1.6%) was significantly lower than that obtained in conscious animals (87.5 +/- 1.7%, P<0.0001). The K/X combination elicited significantly higher LVEF values compared to ISO (P<0.001) and TP (P<0.05). K/X was associated with a lower dispersion of individual LVEF values compared to the other anesthetics. Under K/X, the left ventricular end diastolic diameter (LVdD) was increased (0.60 +/- 0.01 cm) compared to conscious animals (0.41 +/- 0.02 cm), ISO (0.51 +/- 0.02 cm), and TP (0.55 +/- 0.01 cm), P<0.0001. The heart rate observed with K/X was significantly lower than in the remaining conditions. These results indicate that the K/X combination may be the best anesthetic option for the in vivo assessment of cardiac systolic function in hamsters, being associated with a lower LVEF reduction compared to the other agents and showing values closer to those of conscious animals with a lower dispersion of results.
引用
收藏
页数:7
相关论文
共 28 条
[1]   Comparison of 4D-MicroSPECT and MicroCT for Murine Cardiac Function [J].
Befera, Nicholas T. ;
Badea, Cristian T. ;
Johnson, G. Allan .
MOLECULAR IMAGING AND BIOLOGY, 2014, 16 (02) :235-245
[2]   Effects of deep sedation or general anesthesia on cardiac function in mice undergoing cardiovascular magnetic resonance [J].
Berry, Christopher J. ;
Thedens, Daniel R. ;
Light-McGroary, KellyAnn ;
Miller, Jordan D. ;
Kutschke, William ;
Zimmerman, Kathy A. ;
Weiss, Robert M. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2009, 11
[3]   The Syrian hamster as a model for the dilated cardiomyopathy of Chagas' disease: a quantitative echocardiographical and histopathological analysis [J].
Bilate, AMB ;
Salemi, VMC ;
Ramires, FJA ;
de Brito, T ;
Silva, AM ;
Umezawa, ES ;
Mady, C ;
Kalil, J ;
Cunha-Neto, E .
MICROBES AND INFECTION, 2003, 5 (12) :1116-1124
[4]   3D Echo Pilot Study of Geometric Left Ventricular Changes after Acute Myocardial Infarction [J].
Campos Vieira, Marcelo Luiz ;
Oliveira, Wercules Antonio ;
Cordovil, Adriana ;
Tude Rodrigues, Ana Clara ;
Monaco, Claudia Gianini ;
Afonso, Tania ;
Lira Filho, Edgar Bezerra ;
Perin, Marco ;
Fischer, Claudio Henrique ;
Morhy, Samira Saady .
ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2013, 101 (01) :43-51
[5]   Non-invasive echocardiographic studies in mice - Influence of anesthetic regimen [J].
Chaves, AA ;
Weinstein, DM ;
Bauer, JA .
LIFE SCIENCES, 2001, 69 (02) :213-222
[6]   Echocardiographic assessment of left ventricular function [J].
Garcia, MJ .
JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (02) :280-293
[7]  
Goineau S, 2008, CURR PROTOC PHARM
[8]   Effects of avertin versus xylazine-ketamine anesthesia on cardiac function in normal mice [J].
Hart, CYT ;
Burnett, JC ;
Redfield, MM .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 281 (05) :H1938-H1945
[9]   Effects of anesthetics on systemic hemodynamics in mice [J].
Janssen, BJA ;
De Celle, T ;
Debets, JJM ;
Brouns, AE ;
Callahan, MF ;
Smith, TL .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (04) :H1618-H1624
[10]   Echocardiographic evaluation of ventricular remodeling in a mouse model of myocardial infarction [J].
Kanno, S ;
Lerner, DL ;
Schuessler, RB ;
Betsuyaku, T ;
Yamada, KA ;
Saffitz, JE ;
Kovacs, A .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (06) :601-609