Overlapping Stents-Assisted Coiling for Vertebral Artery Dissecting Aneurysm : LVIS Stent within Neuroform EZ Stent

被引:5
|
作者
Liu, Xing-Long [1 ]
Wang, Bin [1 ]
Zhao, Lin-Bo [1 ]
Jia, Zhen-Yu [1 ]
Shi, Hai-Bin [1 ]
Liu, Sheng [1 ]
机构
[1] Nanjing Med Univ, Dept Intervent Radiol, Affiliated Hosp 1, 300 Guangzhou Rd, Nanjing 210029, Peoples R China
关键词
Intracranial aneurysm; Dissecting vertebral artery aneurysm; Endovascular procedures; Stents; ENDOVASCULAR TREATMENT; ENTERPRISE STENTS; RECURRENCE; EFFICACY;
D O I
10.3340/jkns.2021.0275
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective : To evaluate the safety and efficacy of an overlapped stenting-assisted coiling technique in treating vertebral artery dissecting aneurysm (VADA) via Low-profile Visualized Intraluminal Support (LVIS) stent-within-Neuroform EZ stent. Methods : From January 2017 to June 2019, 18 consecutive patients with VADAs (ruptured : unruptured=5 : 13) were treated with the overlapping stents assisted-coiling technique in our center. The overlapping manner was a Neuroform EZ stent being deployed first, followed by LVIS stents placement using the 'shelf' technique. The patients' clinical characteristics, technical feasibility and safety, and immediate and follow-up angiographic results were retrospectively reviewed. Results : Seventeen (94.4%) procedures were technically successful with an exact deployment of the stents and patent parent or perforator arteries. The immediate angiographies after procedure confirmed Raymond class I, II, and III occlusion of VADAs were in 12 (66.7%), two (11.1%), and four cases (22.2%), respectively. Post-procedural complications developed in one patient (5.6%) with minor brainstem infarctions, which resulted from an in-stent thrombosis during the procedure. Angiographic follow-up at 5.7 months (range 3 to 9 months) demonstrated Raymond class I and II occlusion were in all cases (100%). The modified Rankin Scale scores at 21.3 months (range 15 to 42 months) 0-2 in 17 cases (94.4%) and three in one case (5.6%). Conclusion : Overlapping stents via LVIS stent-within-Neuroform EZ stent combined with coiling is safe and effective for patients with VADA in the midterm results.
引用
收藏
页码:523 / 530
页数:8
相关论文
共 49 条
  • [41] Exploring the Feasibility of Pipeline Embolization Device Compared With Stent-Assisted Coiling to Treat Non-saccular, Unruptured, Intradural Vertebral Artery Aneurysms
    Zhang, Yupeng
    Liang, Fei
    Zhang, Yuxiang
    Yan, Peng
    Liang, Shikai
    Ma, Chao
    Jiang, Chuhan
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [42] Stent-Assisted Coil Embolization for Acute Ruptured Dissecting Aneurysm at the P2 Segment of the Posterior Cerebral Artery: A Case Report
    Mitsuhashi, Takashi
    Oishi, Hidenori
    Makino, Kensaku
    Tokugawa, Joji
    Fuse, Atsuhito
    Hishii, Makoto
    JOURNAL OF NEUROENDOVASCULAR THERAPY, 2022, 16 (03) : 157 - 162
  • [43] Stent-Assisted Coil Embolization of a Basilar Artery Dissecting Aneurysm Involved in Skull Base Chordoma Before Endoscopic Transsphenoidal Transclival Resection
    Ishigami, Daiichiro
    Koizumi, Satoshi
    Ishikawa, Osamu
    Shin, Masahiro
    Saito, Nobuhito
    WORLD NEUROSURGERY, 2020, 143 : 466 - 470
  • [44] Application of Optical Frequency Domain Imaging to Recanalized Unruptured Internal Carotid Artery Aneurysm Treated by Flow-Diverting Stent-Assisted Coiling
    Neira, Rafael Ivan
    Yamada, Kiyofumi
    Shirakawa, Manabu
    Uchida, Kazutaka
    Yoshimura, Shinichi
    WORLD NEUROSURGERY, 2021, 146 : 1 - 5
  • [45] Shrinkage of a Vertebral Dissecting Aneurysm After Stent-Assisted Coil Embolization Demonstrated by the Three-Dimensional Driven Equilibrium Sequence -Case Report-
    Takahata, Hideaki
    Ishimaru, Hideki
    Morofuji, Yoichi
    Nakashima, Kazuaki
    Tsutsumi, Keisuke
    Baba, Hiroshi
    Yonekura, Masahiro
    NEUROLOGIA MEDICO-CHIRURGICA, 2012, 52 (04) : 205 - 208
  • [46] Treatment of unruptured intracranial vertebral artery dissection aneurysms with Flow Diverter compared with conventional stent-assisted coiling-a single-center study
    Zhang, Tongfu
    Zhong, Weiying
    Zhou, Donglin
    Xu, Yangyang
    Li, Maogui
    Zhuang, Jianfeng
    Wang, Donghai
    Su, Wandong
    Wang, Yunyan
    ACTA NEUROCHIRURGICA, 2024, 166 (01)
  • [47] Stent-assisted coil embolization of ruptured vertebral artery dissected aneurysm with severe stenosis of bilateral vertebral artery V4 segment by the transmountain technique: a case report and review of the literatures
    Hao, Guangzhi
    Zhang, Zijun
    Han, Yuwei
    Huan, Yu
    Dong, Yushu
    Zhao, Haiyang
    Liang, Guobiao
    FRONTIERS IN SURGERY, 2025, 12
  • [48] The use of single low-profile visualized intraluminal support stent-assisted coiling in the treatment of middle cerebral artery bifurcation unruptured wide-necked aneurysm
    Yan, Yazhou
    Zeng, Zhangwei
    Wu, Yina
    Xiong, Jiachao
    Zhao, Kaijun
    Hong, Bo
    Xu, Yi
    Liu, Jianmin
    Huang, Qinghai
    INTERVENTIONAL NEURORADIOLOGY, 2020, 26 (04) : 461 - 467
  • [49] Artificial Luminal Narrowing on Contrast-Enhanced Magnetic Resonance Angiograms on an Occasion of Stent-Assisted Coiling of Intracranial Aneurysm: In Vitro Comparison Using Two Different Stents with Variable Imaging Parameters
    Seok, Jee Hyun
    Choi, Hyun Seok
    Jung, So-Lyung
    Ahn, Kook-Jin
    Kim, Myeong Jin
    Shin, Yong Sam
    Kim, Bum-soo
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (05) : 550 - 556