Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators

被引:30
|
作者
Beddar, AS [1 ]
Briere, TM [1 ]
Mourtada, FA [1 ]
Vassiliev, ON [1 ]
Liu, HH [1 ]
Mohan, R [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
关键词
Monte Carlo; Burlin cavity theory; plastic scintillation dosimetry; scintillator; water equivalence;
D O I
10.1118/1.1897465
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Detector systems using plastic scintillators can provide instantaneous measurements with high spatial resolution in many applications including small field and high dose gradient field applications. Energy independence and water equivalence are important dosimetric properties that determine whether a detector will be useful in a clinical setting. Using Monte Carlo simulations, we calculated the energy dependence of plastic scintillators when exposed to photon beams in the radiotherapeutic range. These calculations were performed for a detector comprised of a BC-400 plastic scintillator surrounded by a polystyrene wall. Our results showed the plastic scintillation detector to be nearly energy independent over a range of energies from 0.5 to 20 MeV. The ratio of the dose absorbed by the scintillator to that absorbed by water was nearly a constant, approximately equal to 0.98 over the entire energy range of interest. These results confirm the water equivalence of the plastic scintillation detector and are in very good agreement with earlier results obtained using Burlin cavity theory. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1265 / 1269
页数:5
相关论文
共 50 条
  • [41] Exploiting the parallelisation inherent in the windowing approach to Monte Carlo energy perturbation calculations
    Wright, JD
    Reynolds, CA
    THEOCHEM-JOURNAL OF MOLECULAR STRUCTURE, 1998, 427 : 131 - 135
  • [42] Validation of shutdown dose rate Monte Carlo calculations through a benchmark experiment at JET
    Villari, R.
    Angelone, M.
    Batistoni, P.
    Fischer, U.
    Pereslavtsev, P.
    Petrizzi, L.
    Popovichev, S.
    FUSION ENGINEERING AND DESIGN, 2008, 83 (10-12) : 1782 - 1787
  • [43] The energy band memory server algorithm for parallel Monte Carlo transport calculations
    Felker, Kyle G.
    Siegel, Andrew R.
    Smith, Kord S.
    Romano, Paul K.
    Forget, Benoit
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [44] Improved cache performance in Monte Carlo transport calculations using energy banding
    Siegel, A.
    Smith, K.
    Felker, K.
    Romano, P.
    Forget, B.
    Beckman, P.
    COMPUTER PHYSICS COMMUNICATIONS, 2014, 185 (04) : 1195 - 1199
  • [45] Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams
    Tzedakis, A
    Damilakis, JE
    Mazonakis, M
    Stratakis, J
    Varveris, H
    Gourtsoyiannis, N
    MEDICAL PHYSICS, 2004, 31 (04) : 907 - 913
  • [46] Monte Carlo dose calculations for high-dose-rate brachytherapy using GPU-accelerated processing
    Tian, Z.
    Zhang, M.
    Hrycushko, B.
    Albuquerque, K.
    Jiang, S. B.
    Jia, X.
    BRACHYTHERAPY, 2016, 15 (03) : 387 - 398
  • [47] Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose
    Palm, Å
    Kirov, AS
    LoSasso, T
    MEDICAL PHYSICS, 2004, 31 (12) : 3168 - 3178
  • [48] Review of dynamical models for external dose calculations based on Monte Carlo simulations in urbanised areas
    Eged, K
    Kis, Z
    Voigt, G
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2006, 85 (2-3) : 330 - 343
  • [49] Modeling of an industrial environment:: External dose calculations based on Monte Carlo simulations of photon transport
    Kis, Z
    Eged, K
    Voigt, G
    Meckbach, R
    Müller, H
    HEALTH PHYSICS, 2004, 86 (02): : 161 - 173
  • [50] Patient-dependent beam-modifier physics in Monte Carlo photon dose calculations
    von Wittenau, AES
    Bergstrom, PM
    Cox, LJ
    MEDICAL PHYSICS, 2000, 27 (05) : 935 - 947