Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators

被引:30
|
作者
Beddar, AS [1 ]
Briere, TM [1 ]
Mourtada, FA [1 ]
Vassiliev, ON [1 ]
Liu, HH [1 ]
Mohan, R [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
关键词
Monte Carlo; Burlin cavity theory; plastic scintillation dosimetry; scintillator; water equivalence;
D O I
10.1118/1.1897465
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Detector systems using plastic scintillators can provide instantaneous measurements with high spatial resolution in many applications including small field and high dose gradient field applications. Energy independence and water equivalence are important dosimetric properties that determine whether a detector will be useful in a clinical setting. Using Monte Carlo simulations, we calculated the energy dependence of plastic scintillators when exposed to photon beams in the radiotherapeutic range. These calculations were performed for a detector comprised of a BC-400 plastic scintillator surrounded by a polystyrene wall. Our results showed the plastic scintillation detector to be nearly energy independent over a range of energies from 0.5 to 20 MeV. The ratio of the dose absorbed by the scintillator to that absorbed by water was nearly a constant, approximately equal to 0.98 over the entire energy range of interest. These results confirm the water equivalence of the plastic scintillation detector and are in very good agreement with earlier results obtained using Burlin cavity theory. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1265 / 1269
页数:5
相关论文
共 50 条
  • [21] Point flux PL-estimators for Monte Carlo dose calculations
    Donskoy, EN
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 3203 - 3205
  • [22] A MONTE-CARLO PROGRAM FOR THE CALCULATION OF CONTRAST, NOISE AND ABSORBED DOSE IN DIAGNOSTIC-RADIOLOGY
    SANDBORG, M
    DANCE, DR
    PERSLIDEN, J
    CARLSSON, GA
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1994, 42 (03) : 167 - 180
  • [23] Sub-second high dose rate brachytherapy Monte Carlo dose calculations with bGPUMCD
    Hissoiny, Sami
    D'Amours, Michel
    Ozell, Benoit
    Despres, Philippe
    Beaulieu, Luc
    MEDICAL PHYSICS, 2012, 39 (07) : 4559 - 4567
  • [24] MONTE CARLO CALCULATIONS OF NEUTRON DOSE CONVERSION COEFFICIENTS FOR REFERENCE KOREAN MALE
    Kim, Chan Hyeong
    Jeong, Jong Hwi
    Cho, Sungkoo
    Choi, Sang Hyoun
    Chung, Min Suk
    NUCLEAR TECHNOLOGY, 2009, 168 (02) : 345 - 348
  • [25] Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations
    Bush, K.
    Gagne, I. M.
    Zavgorodni, S.
    Ansbacher, W.
    Beckham, W.
    MEDICAL PHYSICS, 2011, 38 (04) : 2208 - 2221
  • [26] Monte Carlo calculations of radiotherapy dose distributions within and around orthopaedic implants
    Katsifis, Georgio Andrew
    McKenzie, David R.
    Suchowerska, Natalka
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 123 - 130
  • [27] An image-based rat model for Monte Carlo organ dose calculations
    Wu, Li
    Zhang, Guozhi
    Luo, Qingming
    Liu, Qian
    MEDICAL PHYSICS, 2008, 35 (08) : 3759 - 3764
  • [28] An anatomically realistic lung model for Monte Carlo-based dose calculations
    Liang, Liang
    Larsen, Edward W.
    Chetty, Indrin J.
    MEDICAL PHYSICS, 2007, 34 (03) : 1013 - 1025
  • [29] The development and application of the Visible Chinese Human model for Monte Carlo dose calculations
    Zhang, Guozhi
    Luo, Qingming
    Zeng, Shaoqun
    Liu, Qian
    HEALTH PHYSICS, 2008, 94 (02): : 118 - 125
  • [30] Dose calculations in heterogeneous volumes with the GATE Monte Carlo software for radiological protection
    Deschler, T.
    Arbor, N.
    Carbillet, F.
    Nourreddine, A.
    RADIOPROTECTION, 2019, 54 (02) : 125 - 132