Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators

被引:30
作者
Beddar, AS [1 ]
Briere, TM [1 ]
Mourtada, FA [1 ]
Vassiliev, ON [1 ]
Liu, HH [1 ]
Mohan, R [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
关键词
Monte Carlo; Burlin cavity theory; plastic scintillation dosimetry; scintillator; water equivalence;
D O I
10.1118/1.1897465
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Detector systems using plastic scintillators can provide instantaneous measurements with high spatial resolution in many applications including small field and high dose gradient field applications. Energy independence and water equivalence are important dosimetric properties that determine whether a detector will be useful in a clinical setting. Using Monte Carlo simulations, we calculated the energy dependence of plastic scintillators when exposed to photon beams in the radiotherapeutic range. These calculations were performed for a detector comprised of a BC-400 plastic scintillator surrounded by a polystyrene wall. Our results showed the plastic scintillation detector to be nearly energy independent over a range of energies from 0.5 to 20 MeV. The ratio of the dose absorbed by the scintillator to that absorbed by water was nearly a constant, approximately equal to 0.98 over the entire energy range of interest. These results confirm the water equivalence of the plastic scintillation detector and are in very good agreement with earlier results obtained using Burlin cavity theory. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1265 / 1269
页数:5
相关论文
共 30 条
[1]  
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[2]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[3]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[4]   Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise [J].
Beddar, AS ;
Suchowerska, N ;
Law, SH .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (05) :783-790
[5]   A NEW SCINTILLATOR DETECTOR SYSTEM FOR THE QUALITY ASSURANCE OF CO-60 AND HIGH-ENERGY THERAPY MACHINES [J].
BEDDAR, AS .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (02) :253-263
[6]   Plastic scintillation dosimetry: optimization of light collection efficiency [J].
Beddar, AS ;
Law, S ;
Suchowerska, N ;
Mackie, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (09) :1141-1152
[7]   A miniature "scintillator-fiberoptic-PMT" detector system for the dosimetry of small fields in stereotactic radiosurgery [J].
Beddar, AS ;
Kinsella, TJ ;
Ikhlef, A ;
Sibata, CH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :924-928
[8]  
Berger M.J., 1963, METHODS COMPUT PHYS, P135
[9]   A GENERAL THEORY OF CAVITY IONISATION [J].
BURLIN, TE .
BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (466) :727-&
[10]   Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from Varian Clinac 2100 series linear accelerators [J].
Cho, SH ;
Vassiliev, ON ;
Lee, S ;
Liu, HH .
MEDICAL PHYSICS, 2005, 32 (01) :137-148