Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators

被引:30
|
作者
Beddar, AS [1 ]
Briere, TM [1 ]
Mourtada, FA [1 ]
Vassiliev, ON [1 ]
Liu, HH [1 ]
Mohan, R [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
关键词
Monte Carlo; Burlin cavity theory; plastic scintillation dosimetry; scintillator; water equivalence;
D O I
10.1118/1.1897465
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Detector systems using plastic scintillators can provide instantaneous measurements with high spatial resolution in many applications including small field and high dose gradient field applications. Energy independence and water equivalence are important dosimetric properties that determine whether a detector will be useful in a clinical setting. Using Monte Carlo simulations, we calculated the energy dependence of plastic scintillators when exposed to photon beams in the radiotherapeutic range. These calculations were performed for a detector comprised of a BC-400 plastic scintillator surrounded by a polystyrene wall. Our results showed the plastic scintillation detector to be nearly energy independent over a range of energies from 0.5 to 20 MeV. The ratio of the dose absorbed by the scintillator to that absorbed by water was nearly a constant, approximately equal to 0.98 over the entire energy range of interest. These results confirm the water equivalence of the plastic scintillation detector and are in very good agreement with earlier results obtained using Burlin cavity theory. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1265 / 1269
页数:5
相关论文
共 50 条
  • [1] Monte Carlo-based investigation of absorbed-dose energy dependence of radiochromic films in high energy brachytherapy dosimetry
    Subhalaxmi, Mishra
    Selvam, T. Palani
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 351 - 362
  • [2] Monte Carlo estimation of absorbed dose to organs in computed tomography
    Alonso, M
    Barriuso, T
    Castañeda, MJ
    Díaz-Caneja, N
    Gutiérrez, I
    Villar, E
    HEALTH PHYSICS, 2002, 82 (02): : 233 - 239
  • [3] Monte Carlo estimation of absorbed dose to organs in diagnostic radiology
    Alonso, M
    Barriuso, T
    Castañeda, MJ
    Díaz-Caneja, N
    Gutiérrez, I
    Sarmiento, JJ
    Villar, E
    HEALTH PHYSICS, 1999, 76 (04): : 388 - 392
  • [4] A Monte Carlo method for calculating the energy response of plastic scintillators to polarized photons below 100 keV
    Mizuno, T.
    Kanai, Y.
    Kataoka, J.
    Kiss, M.
    Kurita, K.
    Pearce, M.
    Tajima, H.
    Takahashi, H.
    Tanaka, T.
    Ueno, M.
    Umeki, Y.
    Yoshida, H.
    Arimoto, M.
    Axelsson, M.
    Bettolo, C. Marini
    Bogaert, G.
    Chen, P.
    Craig, W.
    Fukazawa, Y.
    Gunji, S.
    Kamae, T.
    Katsuta, J.
    Kawai, N.
    Kishimoto, S.
    Klamra, W.
    Larsson, S.
    Madejski, G.
    Ng, J. S. T.
    Ryde, F.
    Rydstrom, S.
    Takahashi, T.
    Thurston, T. S.
    Varner, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 600 (03) : 609 - 617
  • [5] Monte Carlo-based Investigation of Absorbed-dose Energy Dependence of Thermoluminescent Dosimeters in Therapeutic Proton and Carbon Ion Beams
    Chattaraj, Arghya
    Mishra, Subhalaxmi
    Selvam, T. Palani
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (02) : 148 - 154
  • [6] Monte Carlo simulation of β-γ coincidence system using plastic scintillators in 4π geometry
    Dias, M. S.
    Piuvezam-Filho, H.
    Baccarelli, A. M.
    Takeda, M. N.
    Koskinas, M. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) : 380 - 383
  • [7] Assessment of different MCNP Monte Carlo codes in electron absorbed dose
    Nedaie, Hassan Ali
    Mosleh-Shirazi, M. A.
    Gharaati, H.
    Shariari, M.
    Allahverdi, M.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2006, 11 (06) : 293 - 298
  • [8] Monte Carlo calculations of radiotherapy dose in "homogeneous" anatomy
    Kairn, Tanya
    Livingstone, Alexander G.
    Crowe, Scott B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 156 - 165
  • [9] Evaluation of absorbed radiation dose on pregnant and fetus: Monte Carlo code
    Turkoglu, Ozlem
    Kara, Umit
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2020, 11 : 183 - 187
  • [10] Optical Monte Carlo transport in scintillators
    Panman, A
    Morton, EJ
    Kundu, A
    Sellin, PJ
    RADIATION SOURCES AND RADIATION INTERACTIONS, 1999, 3771 : 135 - 143