On-line Partial Discharge Monitoring of Substation Power Transformers

被引:0
|
作者
Huzmezan, Mihai [1 ]
机构
[1] Power Diagnostix Syst GmbH, Aachen, Germany
关键词
Power transformers Condition Based Maintenance; Partial Discharge On-Line Monitoring; Partial Discharge in combination with Dissolved Gas Analysis (DGA) and Bushing Monitoring (BM);
D O I
10.1109/EIC51169.2022.9833201
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The power transformer, a central node of power grids ensuring electrical energy flows, can experience thermal, electric, ambient or mechanical (TEAM) stresses during manufacturing, transportation, installation and operation. Such stresses in time can deteriorate its insulation ecosystem. On-line systems designed and engineered to provide continuous monitoring of Partial Discharge (PD) are being discussed herein. The content of this paper allows decision makers to take note of required PD monitoring capabilities leading to defects being promptly revealed, understood, and therefore removed. This article discusses the need for on-line monitoring and provides an overview of key functionalities, features and options for PD diagnostics and its relationship to insulation condition. The advantages of on-line PD monitors are outlined via condition-based maintenance examples where PD information played a key role.
引用
收藏
页码:347 / 352
页数:6
相关论文
共 50 条
  • [1] On-line partial discharge calibration and monitoring for power transformers
    Farag, AS
    Shewhdi, MH
    Jin, X
    Wang, C
    Cheng, TC
    Dong, X
    Gao, S
    Jing, W
    Wang, Z
    ELECTRIC POWER SYSTEMS RESEARCH, 1999, 50 (01) : 47 - 54
  • [2] Signal processing technique for on-line partial discharge monitoring of power transformers
    Gao, Shengyou
    Zhu, Deheng
    Tan, Kexiong
    Xie, Liangpin
    Dorr, Richard
    Guuinic, Philippe
    2003, Press of Tsinghua University (43):
  • [3] Analysis and suppression of interference for on-line monitoring of partial discharge of power transformers
    Wang, C
    Jin, XH
    Cheng, TC
    Zhang, SB
    Dong, XZ
    Wang, ZD
    Lin, D
    Zhu, DH
    IEEE 1997 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I AND II, 1997, : 530 - 533
  • [4] Study on on-line calibration of partial discharge in power transformers
    Dong, Xuzhu
    Wang, Changchang
    Wang, Zhongdong
    Gao, Shengyou
    Jing, Weihong
    Hao, Dezhi
    Ma, Weiping
    Zheng, Lianghua
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 1997, 37 (04): : 40 - 44
  • [5] Advantage of On-Line Partial Discharge Continuous Monitoring of Medium Voltage Substation
    Blokhintsev, Igor
    Patterson, Calvin L.
    Cassidy, Brian J.
    Loesch, Armin H.
    2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 153 - +
  • [6] Study of on-line monitoring method of partial discharge for power transformers based on RFCT and microstrip antenna
    Cheng, YH
    Chen, Y
    Liu, T
    Xu, XW
    Ji, LL
    Chen, W
    Chen, LX
    PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING CONFERENCE, 2005, : 103 - 107
  • [7] Study of suppressing interference in partial discharge (PD) on-line monitoring for transformers
    Shanghai Jiaotong University, Shanghai 200030, China
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2000, 24 (21): : 49 - 51
  • [8] Continuous on-line partial discharge monitoring of power generators
    Kheirmand, A
    Leijon, M
    IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 496 - 499
  • [9] On-line partial discharge measurement on instrument transformers
    Blackburn, TR
    Phung, BT
    Liu, Z
    James, RE
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 497 - 500
  • [10] A New Method for On-Line Monitoring of Bushings and Partial Discharges of Power Transformers
    Koch, Maik
    Krueger, Michael
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 1205 - 1208