Cone beam optical CT scanner for 3D dosimetry

被引:4
作者
Miller, J
Adamovics, J
Dietrich, J
机构
[1] Modus Med Devices Inc, London, ON, Canada
[2] Heuris Pharma LLC, Skillman, NJ USA
关键词
D O I
10.1118/1.1998568
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the performance of a cone beam optical CT scanner and to evaluate use of the scanner with a 3D solid radiochromic dosimeter. Method and Materials: The operating characteristics of a cone beam optical CT scanner were investigated using phantoms and solid dosimeters. The scanner acquires projection images (12 degree fan angle, 9 degree cone angle) during a single 360 degree rotation of a sample. 3D Images are reconstructed using Feldkamp backprojection with a Hamming filter. Background attenuation coefficients are removed by subtracting reference (pre‐irradiation) images from data (post‐irradiation) images prior to reconstruction. Reconstructed images have isotropic 2 mm, 1 mm, or 0.5 mm voxel dimensions in a 10 cm cube. Spatial resolution and image distortion were evaluated with a wire phantom and holes drilled in a solid dosimeter. Solid dosimeters were irradiated with a rectangular field and a complex Tomotherapy field. Profiles from scanned images were compared to profiles in calculated dose maps. Results: Reconstructed images of the geometry phantoms showed no spatial distortions. Artifacts are similar in appearance to sampling and beam hardening artifacts common in X‐ray CT. Attenuation coefficients in neutral density liquids are linear with respect to the spectrophotometer readings. Line profiles through calculated and measured dosemaps show qualitative agreement. Scanning times varied from 3 to 9 minutes. Reconstruction times varied from 2 to 20 minutes. The total time to scan a dosimeter was less than 1 hour. Conclusion: The optical CT scanner and solid dosimeter form a promising 3D dosimetry tool. Geometric accuracy, spatial resolution and imaging times are within clinical requirements Conflict of Interest: This research is funded by Modus Medical Devices Inc. and Heuris Pharma LLC. The authors have a commercial interest in the scanner and/or the dosimeter. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2138 / 2138
页数:1
相关论文
共 50 条
  • [21] A fast dual wavelength laser beam fluid-less optical CT scanner for radiotherapy 3D gel dosimetry I: design and development
    Ramm, Daniel
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (04)
  • [22] 3D CT pancreatography vs. cone beam CT pancreatography
    Ueno, J
    Kitagawa, M
    Makimoto, Y
    Matsuzaki, K
    Yoshida, S
    Nishitani, H
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 982 - 982
  • [23] Characterization of a cone beam optical scanner
    Ravindran, P. B.
    Thomas, H. M.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [24] Development of 3D Dosimetry System using Polymer Gel (TENOMAG) and Optical-CT Scanner in Prostate IMRT
    Lee, S.
    Yi, J.
    Park, J.
    Cho, S.
    Shim, J.
    Chang, K.
    Cao, Y.
    Lee, S.
    Huh, H.
    Kim, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S748 - S748
  • [25] Benchmarking of a new integrated 3D dosimetry system against Monte Carlo calculations and an established optical CT scanner
    Lakrad, Kawtar
    Oldham, Mark
    Quinn, Benjamin
    Adamson, Justus
    MEDICAL PHYSICS, 2025,
  • [26] Characterization of a parallel-beam CCD optical-CT apparatus for 3D radiation dosimetry
    Krstajic, Nikola
    Doran, Simon J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (13) : 3693 - 3713
  • [27] 3D cone-beam CT reconstruction for circular trajectories
    Grass, M
    Köhler, T
    Proksa, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) : 329 - 347
  • [28] Application of cone beam CT 3D images to cephalometric analysis
    Ogawa, Naoki
    Miyazaki, Yoshikazu
    Kubota, Masato
    Huang, John C.
    Miller, Arthur J.
    Maki, Koutaro
    ORTHODONTIC WAVES, 2010, 26 (04): : 415 - 454
  • [29] 3D IMAGE GUIDED BRACHYTHERAPY USING CONE BEAM CT
    Reniers, B.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2009, 91 : S33 - S33
  • [30] Linear Accuracy of Cone Beam CT Derived 3D Images
    Brown, April A.
    Scarfe, William C.
    Scheetz, James P.
    Silveira, Anibal M.
    Farman, Allan G.
    ANGLE ORTHODONTIST, 2009, 79 (01) : 150 - 157