Cone beam optical CT scanner for 3D dosimetry

被引:4
|
作者
Miller, J
Adamovics, J
Dietrich, J
机构
[1] Modus Med Devices Inc, London, ON, Canada
[2] Heuris Pharma LLC, Skillman, NJ USA
关键词
D O I
10.1118/1.1998568
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the performance of a cone beam optical CT scanner and to evaluate use of the scanner with a 3D solid radiochromic dosimeter. Method and Materials: The operating characteristics of a cone beam optical CT scanner were investigated using phantoms and solid dosimeters. The scanner acquires projection images (12 degree fan angle, 9 degree cone angle) during a single 360 degree rotation of a sample. 3D Images are reconstructed using Feldkamp backprojection with a Hamming filter. Background attenuation coefficients are removed by subtracting reference (pre‐irradiation) images from data (post‐irradiation) images prior to reconstruction. Reconstructed images have isotropic 2 mm, 1 mm, or 0.5 mm voxel dimensions in a 10 cm cube. Spatial resolution and image distortion were evaluated with a wire phantom and holes drilled in a solid dosimeter. Solid dosimeters were irradiated with a rectangular field and a complex Tomotherapy field. Profiles from scanned images were compared to profiles in calculated dose maps. Results: Reconstructed images of the geometry phantoms showed no spatial distortions. Artifacts are similar in appearance to sampling and beam hardening artifacts common in X‐ray CT. Attenuation coefficients in neutral density liquids are linear with respect to the spectrophotometer readings. Line profiles through calculated and measured dosemaps show qualitative agreement. Scanning times varied from 3 to 9 minutes. Reconstruction times varied from 2 to 20 minutes. The total time to scan a dosimeter was less than 1 hour. Conclusion: The optical CT scanner and solid dosimeter form a promising 3D dosimetry tool. Geometric accuracy, spatial resolution and imaging times are within clinical requirements Conflict of Interest: This research is funded by Modus Medical Devices Inc. and Heuris Pharma LLC. The authors have a commercial interest in the scanner and/or the dosimeter. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2138 / 2138
页数:1
相关论文
共 50 条
  • [1] A prototype fan-beam optical CT scanner for 3D dosimetry
    Campbell, Warren G.
    Rudko, D. A.
    Braam, Nicolas A.
    Wells, Derek M.
    Jirasek, Andrew
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Imaging Protocol Investigations with a Fan-Beam Optical CT Scanner for 3D Dosimetry
    Campbell, W.
    Jirasek, A.
    Wells, D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Optical CT scanner for in-air readout of gels for external radiation beam 3D dosimetry
    Ramm, Daniel
    Rutten, Thomas P.
    Shepherd, Justin
    Bezak, Eva
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3853 - 3868
  • [4] DEVELOPMENT OF A 3D CT SCANNER WITH A CONE-BEAM AND VIDEOFLUOROSCOPIC SYSTEM
    ENDO, M
    SATOH, K
    OKAZAKI, T
    HATTORI, Y
    KOBAYASHI, S
    JIMBO, M
    RADIOLOGY, 1995, 197 : 292 - 292
  • [5] Study on reconstructed image of 3D cone-beam CT scanner
    Nakamori, N
    Sudou, T
    Kanamori, H
    Endou, M
    Kusakabe, M
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 696 - 705
  • [6] Performance of an improved first generation optical CT scanner for 3D dosimetry
    Qian, Xin
    Adamovics, John
    Wuu, Cheng-Shie
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (24): : N321 - N331
  • [7] 3D IN VIVO DOSIMETRY USING MEGAVOLTAGE CONE-BEAM CT AND EPID DOSIMETRY
    van Elmpt, Wouter
    Nusten, Sebastiaan
    Petit, Steven
    Munheer, Ben
    Lambin, Philippe
    Dekker, Andre
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05): : 1580 - 1587
  • [8] The performance of an optical cone-beam CT scanner adapted for radiochromic film dosimetry
    Babic, Steven
    Jordan, Kevin
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21): : N377 - N389
  • [9] Laser cone beam computed tomography scanner geometry for large volume 3D dosimetry
    Jordan, K. J.
    Turnbull, D.
    Batista, J. J.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [10] Effect of light source instability on uniformity of 3D reconstructions from a cone beam optical CT scanner
    J. Begg
    M. L. Taylor
    L. Holloway
    T. Kron
    R. D. Franich
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 791 - 798