Using photoplethysmography in heart rate monitoring of patients with epilepsy

被引:26
|
作者
van Andel, Judith [1 ]
Ungureanu, Constantin [2 ,3 ]
Aarts, Ronald [3 ,4 ]
Leijten, Frans [1 ]
Arends, Johan [2 ]
机构
[1] Univ Med Ctr Utrecht, Dept Clin Neurophysiol, Brain Ctr Rudolf Magnus, NL-3584 CX Utrecht, Netherlands
[2] Acad Ctr Epileptol Kempenhaeghe, Dept Clin Neurophysiol, NL-5591 VE Heeze, Netherlands
[3] Eindhoven Univ Technol, NL-5612 AZ Eindhoven, Netherlands
[4] Philips Res, NL-5656 AE Eindhoven, Netherlands
关键词
Epilepsy; Seizure detection; Heart rate; ECG; Photoplethysmography; Ambulatory monitoring; SEIZURES;
D O I
10.1016/j.yebeh.2015.02.018
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
Heart rate is a useful neurophysiological sign when monitoring seizures in patients with epilepsy. In an ambulatory setting, heart rate is measured with ECG involving electrodes on the skin. This method is uncomfortable which is burdensome for patients and is sensitive to motion artifacts, which decrease the usability of measurements. In this study, green light photoplethysmography, an optical technique arising from the fitness industry, was evaluated for usefulness in a medical setting. Simultaneous overnight measurements of HR with a commercially available optical heart rate (OHR) sensor and with ECG (HRECG) were performed in 7 patients with epilepsy. Overall, there was no significant difference between OHR and HRECG in random 10-minute periods during wakefulness (p=0.69) and sleep (p=1.00). The Bland-Altman analysis showed negligible mean differences. Limits of agreement were higher during wakefulness and during the occurrence of two seizures possibly because of less reliable HRECG measurements due to motion artifacts. Optical heart rate seems less sensitive to these motion artifacts, and measurements are more user-friendly. The optical heart rate sensor may fill the gap of systems for ambulatory heart rate monitoring and can be especially useful in the context of seizure detection in patients with epilepsy. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:142 / 145
页数:4
相关论文
共 50 条
  • [1] Noncontact Monitoring of Heart Rate and Heart Rate Variability in Geriatric Patients Using Photoplethysmography Imaging
    Yu, Xinchi
    Laurentius, Thea
    Bollheimer, Cornelius
    Leonhardt, Steffen
    Antink, Christoph Hoog
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (05) : 1781 - 1792
  • [2] Kick LL: A Smartwatch for Monitoring Respiration and Heart Rate using Photoplethysmography
    Hoilett, Orlando S.
    Twibell, Ashlyn M.
    Srivastava, Rohit
    Linnes, Jacqueline C.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3821 - 3824
  • [3] Measurement of Heart Rate Using Photoplethysmography
    Saquib, Nazmus
    Papon, Md Tarikul Islam
    Ahmad, Ishtiyaque
    Rahman, Ashikur
    2015 INTERNATIONAL CONFERENCE ON NETWORKING SYSTEMS AND SECURITY (NSYSS), 2015, : 158 - 163
  • [4] Real-Time Approaches for Heart Rate Monitoring using Imaging Photoplethysmography
    Fallet, Sibylle
    Mirmohamadsadeghi, Leila
    Moser, Virginie
    Braun, Fabian
    Vesin, Jean-Marc
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 345 - 348
  • [5] A Video based Heart Rate Monitoring System for Drivers Using Photoplethysmography Signal
    Hui, Ma Li
    Nisar, Humaira
    Ho, Yeap Kim
    Chiong, Teh Peh
    2018 IEEE REGION 10 HUMANITARIAN TECHNOLOGY CONFERENCE (R10-HTC), 2018,
  • [6] Continuous heart rhythm monitoring using mobile photoplethysmography in ambulatory patients
    Hochstadt, Aviram
    Havakuk, Ofer
    Chorin, Ehud
    Schwartz, Arie Lorin
    Merdler, Ilan
    Laufer, Michal
    Lubman, Natan
    Ghantous, Eihab
    Viskin, Sami
    Rosso, Raphael
    JOURNAL OF ELECTROCARDIOLOGY, 2020, 60 : 138 - 141
  • [7] Design of a Real-Time Heart Rate Monitoring System Using Photoplethysmography and Smartphone
    Singh, Neharika
    Prince, Aashirvad
    Chattopadhyay, Swarnendu
    Patra, Rusha
    Mukherjee, Banibrata
    IEEE INDICON: 15TH IEEE INDIA COUNCIL INTERNATIONAL CONFERENCE, 2018,
  • [8] Heart Rate Monitoring During Physical Exercise From Photoplethysmography Using Neural Network
    Zhu, Lianning
    Kan, Chen
    Du, Yuncheng
    Du, Dongping
    IEEE SENSORS LETTERS, 2019, 3 (01)
  • [9] A NEW APPROACH FOR HEART RATE MONITORING USING PHOTOPLETHYSMOGRAPHY SIGNALS CONTAMINATED BY MOTION ARTIFACTS
    Sun, Biao
    Feng, Hui
    Zhang, Zhilin
    2016 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING PROCEEDINGS, 2016, : 809 - 813
  • [10] A Heart Rate Monitoring Framework for Real-World Drivers Using Remote Photoplethysmography
    Huang, Po-Wei
    Wu, Bing-Jhang
    Wu, Bing-Fei
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (05) : 1397 - 1408