In-channel amperometric detection for microchip electrophoresis using a wireless isolated potentiostat

被引:34
|
作者
Gunasekara, Dulan B. [1 ,2 ]
Hulvey, Matthew K. [1 ,3 ]
Lunte, Susan M. [1 ,2 ,4 ]
机构
[1] Univ Kansas, Ralph N Adams Inst Bioanalyt Chem, Lawrence, KS 66047 USA
[2] Univ Kansas, Dept Chem, Lawrence, KS 66047 USA
[3] Akermin Inc, St Louis, MO USA
[4] Univ Kansas, Dept Pharmaceut Chem, Lawrence, KS 66047 USA
关键词
Electrically isolated potentiostat; In-channel electrochemical detection; Microchip electrophoresis; Peroxynitrite; Reactive nitrogen species; CAPILLARY-ELECTROPHORESIS; ELECTROCHEMICAL DETECTION; POLY(DIMETHYLSILOXANE) MICROCHIP; ELECTRODES; SEPARATION; DECOUPLER; DEVICE; CHIPS; CE;
D O I
10.1002/elps.201000681
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The combination of microchip electrophoresis with amperometric detection leads to a number of analytical challenges that are associated with isolating the detector from the high voltages used for the separation. While methods such as end-channel alignment and the use of decouplers have been employed, they have limitations. A less common method has been to utilize an electrically isolated potentiostat. This approach allows placement of the working electrode directly in the separation channel without using a decoupler. This paper explores the use of microchip electrophoresis and electrochemical detection with an electrically isolated potentiostat for the separation and in-channel detection of several biologically important anions. The separation employed negative polarity voltages and tetradecyltrimethylammonium bromide (as a buffer modifier) for the separation of nitrite (NO(2)(-)), glutathione, ascorbic acid, and tyrosine. A half-wave potential shift of approximately negative 500 mV was observed for NO(2)(-) and H(2)O(2) standards in the in-channel configuration compared to end-channel. Higher separation efficiencies were observed for both NO(2)(-) and H(2)O(2) with the in-channel detection configuration. The limits of detection were approximately two-fold lower and the sensitivity was approximately two-fold higher for in-channel detection of nitrite when compared to end-channel. The application of this microfluidic device for the separation and detection of biomarkers related to oxidative stress is described.
引用
收藏
页码:832 / 837
页数:6
相关论文
共 50 条
  • [41] Microchip electrophoresis with amperometric detection for the study of the generation of nitric oxide by NONOate salts
    Dulan B. Gunasekara
    Matthew K. Hulvey
    Susan M. Lunte
    José Alberto Fracassi da Silva
    Analytical and Bioanalytical Chemistry, 2012, 403 : 2377 - 2384
  • [42] Biological applications of microchip electrophoresis with amperometric detection: in vivo monitoring and cell analysis
    Schilly, Kelci M.
    Gunawardhana, Shamal M.
    Wijesinghe, Manjula B.
    Lunte, Susan M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (24) : 6101 - 6119
  • [43] Microchip capillary electrophoresis with an end-channel amperometric detector and its preliminary application
    Wu, YY
    Qu, F
    Lin, JM
    CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (02) : 155 - 159
  • [44] Biological applications of microchip electrophoresis with amperometric detection: in vivo monitoring and cell analysis
    Kelci M. Schilly
    Shamal M. Gunawardhana
    Manjula B. Wijesinghe
    Susan M. Lunte
    Analytical and Bioanalytical Chemistry, 2020, 412 : 6101 - 6119
  • [45] Use of 3D printing to integrate microchip electrophoresis with amperometric detection
    Selemani, Major A.
    Martin, R. Scott
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (21) : 4749 - 4758
  • [46] Microchip electrophoresis with amperometric detection method for profiling cellular nitrosative stress markers
    Gunasekara, Dulan B.
    Siegel, Joseph M.
    Caruso, Giuseppe
    Hulvey, Matthew K.
    Lunte, Susan M.
    ANALYST, 2014, 139 (13) : 3265 - 3273
  • [47] Integrating amperometric detection with electrophoresis microchip devices for biochemical assays: Recent developments
    Ghanim, M. H.
    Abdullah, M. Z.
    TALANTA, 2011, 85 (01) : 28 - 34
  • [48] Microchip electrophoresis with amperometric detection for the study of the generation of nitric oxide by NONOate salts
    Gunasekara, Dulan B.
    Hulvey, Matthew K.
    Lunte, Susan M.
    Fracassi da Silva, Jose Alberto
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (08) : 2377 - 2384
  • [49] Direct analysis of trace phenolics with a microchip: In-channel sample preconcentration, separation, and electrochemical detection
    Shiddiky, Muhammad J. A.
    Park, Hyun
    Shim, Yoon-Bo
    ANALYTICAL CHEMISTRY, 2006, 78 (19) : 6809 - 6817
  • [50] Detection of telomerase activity using microchip electrophoresis
    Karasawa, Koji
    Arakawa, Hidetoshi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 993 : 14 - 19