In-channel amperometric detection for microchip electrophoresis using a wireless isolated potentiostat

被引:34
|
作者
Gunasekara, Dulan B. [1 ,2 ]
Hulvey, Matthew K. [1 ,3 ]
Lunte, Susan M. [1 ,2 ,4 ]
机构
[1] Univ Kansas, Ralph N Adams Inst Bioanalyt Chem, Lawrence, KS 66047 USA
[2] Univ Kansas, Dept Chem, Lawrence, KS 66047 USA
[3] Akermin Inc, St Louis, MO USA
[4] Univ Kansas, Dept Pharmaceut Chem, Lawrence, KS 66047 USA
关键词
Electrically isolated potentiostat; In-channel electrochemical detection; Microchip electrophoresis; Peroxynitrite; Reactive nitrogen species; CAPILLARY-ELECTROPHORESIS; ELECTROCHEMICAL DETECTION; POLY(DIMETHYLSILOXANE) MICROCHIP; ELECTRODES; SEPARATION; DECOUPLER; DEVICE; CHIPS; CE;
D O I
10.1002/elps.201000681
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The combination of microchip electrophoresis with amperometric detection leads to a number of analytical challenges that are associated with isolating the detector from the high voltages used for the separation. While methods such as end-channel alignment and the use of decouplers have been employed, they have limitations. A less common method has been to utilize an electrically isolated potentiostat. This approach allows placement of the working electrode directly in the separation channel without using a decoupler. This paper explores the use of microchip electrophoresis and electrochemical detection with an electrically isolated potentiostat for the separation and in-channel detection of several biologically important anions. The separation employed negative polarity voltages and tetradecyltrimethylammonium bromide (as a buffer modifier) for the separation of nitrite (NO(2)(-)), glutathione, ascorbic acid, and tyrosine. A half-wave potential shift of approximately negative 500 mV was observed for NO(2)(-) and H(2)O(2) standards in the in-channel configuration compared to end-channel. Higher separation efficiencies were observed for both NO(2)(-) and H(2)O(2) with the in-channel detection configuration. The limits of detection were approximately two-fold lower and the sensitivity was approximately two-fold higher for in-channel detection of nitrite when compared to end-channel. The application of this microfluidic device for the separation and detection of biomarkers related to oxidative stress is described.
引用
收藏
页码:832 / 837
页数:6
相关论文
共 50 条
  • [41] Determination of naphthenic acids in produced water by using microchip electrophoresis with integrated contactless conductivity detection
    Pinheiro, Kemilly M. P.
    Duarte, Lucas M.
    Rodrigues, Marcella F.
    Vaz, Boniek G.
    Medeiros Junior, Iris
    Carvalho, Rogerio M.
    Coltro, Wendell K. T.
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1677
  • [42] Microchip for continuous DNA analysis based on gel electrophoresis coupled with co-injection of size markers and in-channel staining
    Kwak, Byoung Joo
    Kim, Hanok
    Park, Nokyoung
    Hahn, Jong Hoon
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (23) : 5685 - 5694
  • [43] Fabrication and performance of a three-dimensionally adjustable device for the amperometric detection of microchip capillary electrophoresis
    Chen, G
    Bao, HM
    Yang, PY
    ELECTROPHORESIS, 2005, 26 (24) : 4632 - 4640
  • [44] Amperometric PDMS/glass capillary electrophoresis-based biosensor microchip for catechol and dopamine detection
    Schöning, MJ
    Jacobs, M
    Muck, A
    Knobbe, DT
    Wang, J
    Chatrathi, M
    Spillmann, S
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2): : 688 - 694
  • [45] Multiple-point electrochemical detection for a dual-channel hybrid PDMS-glass microchip electrophoresis device
    Castano-Alvarez, Mario
    Fernandez-la-Vilia, Ana
    Pozo-Ayuso, Diego F.
    Teresa Fernandez-Abedul, Maria
    Costa-Garcia, Agustin
    ELECTROPHORESIS, 2009, 30 (19) : 3372 - 3380
  • [46] Capillary electrophoresis with constant potential amperometric detection using a nickel microelectrode for detection of carbohydrates
    Fermier, AM
    Colon, LA
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1996, 19 (11): : 613 - 616
  • [47] Microchip capillary electrophoresis using on-line chemiluminescence detection
    Hashimoto, M
    Tsukagoshi, K
    Nakajima, R
    Kondo, K
    Arai, A
    JOURNAL OF CHROMATOGRAPHY A, 2000, 867 (1-2) : 271 - 279
  • [48] Highly Sensitive Detection of Monosaccharides on Microchip Electrophoresis Using pH Discontinuous Solution System
    Nagata, Hideya
    Itoh, Tamitake
    Baba, Yoshinobu
    Ishikawa, Mitsuru
    ANALYTICAL SCIENCES, 2010, 26 (07) : 731 - 736
  • [49] Integration of microchip electrophoresis with electrochemical detection using an epoxy-based molding method to embed multiple electrode materials
    Johnson, Alicia S.
    Selimovic, Asmira
    Martin, R. Scott
    ELECTROPHORESIS, 2011, 32 (22) : 3121 - 3128
  • [50] Simultaneous determination of thyroxine and triiodothyronine in pharmaceutical formulations using capillary electrophoresis with amperometric detection
    Sun, Yan
    Zhao, Xiaoyin
    Li, Ping
    Shi, Guoyue
    Zhou, Tianshu
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (16) : 2417 - 2422