PET/CT:: a new imaging technology in nuclear medicine

被引:116
作者
Schöder, H
Erdi, YE
Larson, SM
Yeung, HWD
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol & Nucl Med, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
PET/CT imaging; technical aspects; acquisition protocols; artifacts; clinical applications;
D O I
10.1007/s00259-003-1299-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This review discusses the technical background of combined PET and CT and considers the clinical applications of PET/CT imaging. Questions addressed include: Is PET/CT superior to PET imaging alone? If so, in which patient populations and in what respect? Can PET/CT imaging affect patient management? Can PET/CT be practiced economically? While much work remains to be done, the available data clearly suggest that PET/CT decreases imaging time per patient and, even for the experienced reader, significantly reduces the number of equivocal PET interpretations. PET/CT also has the ability to improve accuracy of PET image interpretation and to affect clinical decision making, thereby improving patient management. The nuclear medicine community should approach this new technology with an open mind and focus on its clinical usefulness. The decision regarding whether PET/CT should be part of the equipment in a given nuclear medicine or radiology practice largely depends on the specific patient population. It is concluded that present skepticism concerning combined PET/CT will subside once critics of this new modality have had the opportunity to clearly see on images its many advantages compared with either PET alone or conventional image fusion approaches.
引用
收藏
页码:1419 / 1437
页数:19
相关论文
共 62 条
  • [1] Prospective comparison of 18F-FDG PET with conventional imaging modalities (CT, MRI, US) in lymph node staging of head and neck cancer
    Adams, S
    Baum, RP
    Stuckensen, T
    Bitter, K
    Hör, G
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (09) : 1255 - 1260
  • [2] Akhurst TJ, 2002, RADIOLOGY, V225, P275
  • [3] [Anonymous], TEACHING ABORIGINAL
  • [4] Whole-body positron emission tomography-CT: Optimized CT using oral and IV contrast materials
    Antoch, G
    Freudenberg, LS
    Stattaus, J
    Jentzen, W
    Mueller, SP
    Debatin, JF
    Bockisch, A
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (06) : 1555 - 1560
  • [5] Antoch G, 2002, J NUCL MED, V43, P1339
  • [6] Barrington SF, 1996, J NUCL MED, V37, P1127
  • [7] Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology
    Beyer, T
    Antoch, G
    Blodgett, T
    Freudenberg, LF
    Akhurst, T
    Mueller, S
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) : 588 - 596
  • [8] Bhatnagar A, 2002, RADIOLOGY, V225, P599
  • [9] PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
    Burger, C
    Goerres, G
    Schoenes, S
    Buck, A
    Lonn, AHR
    von Schulthess, GK
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) : 922 - 927
  • [10] Burger I, 2002, RADIOLOGY, V225, P424