EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres

被引:84
作者
Chiesa, Carlo [1 ]
Sjogreen-Gleisner, Katarina [2 ]
Walrand, Stephan [3 ]
Strigari, Lidia [4 ]
Flux, Glenn [5 ,6 ]
Gear, Jonathan [5 ,6 ]
Stokke, Caroline [7 ]
Gabina, Pablo Minguez [8 ]
Bernhardt, Peter [9 ,10 ]
Konijnenberg, Mark [11 ]
机构
[1] Fdn IRCCS Ist Nazl Tumori, Nucl Med Unit, Milan, Italy
[2] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[3] Catholic Univ Louvain, Nucl Med Mol Imaging Radiotherapy & Oncol Unit MI, IECR, Brussels, Belgium
[4] IRCCS Azienda Osped Univ Bologna, Med Phys Div, Bologna, Italy
[5] Royal Marsden Hosp, Joint Dept Phys, Sutton, Surrey, England
[6] Inst Canc Res, Sutton, Surrey, England
[7] Oslo Univ Hosp, Dept Diagnost Phys, Oslo, Norway
[8] Gurutzeta Cruces Univ Hosp, Dept Med Phys & Radiat Protect, Baracaldo, Spain
[9] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[10] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
[11] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
关键词
Radioembolization dosimetry; Tc-99m-MAA; Y-90; microspheres; Lung shunt; Liver dosimetry; Tumour dosimetry; PET; Prospective; retrospective dosimetry; SELECTIVE INTERNAL RADIOTHERAPY; VOXEL S-VALUES; HEPATOCELLULAR-CARCINOMA; GLASS MICROSPHERES; RADIATION-THERAPY; PARTITION MODEL; TC-99M-MACROAGGREGATED ALBUMIN; BREMSSTRAHLUNG SPECT/CT; IMAGE-RECONSTRUCTION; QUANTITATIVE SPECT;
D O I
10.1186/s40658-021-00394-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in Y-90 microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of Tc-99m albumin macro-aggregates (MAA) and Y-90 microsphere biodistribution is also assumed. The large observed discrepancies in some patients between Tc-99m-MAA predictions and actual Y-90 microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments. Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected Tc-99m-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and Y-90 TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected Tc-99m-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative Y-90 bremsstrahlung SPECT can be used if dedicated correction methods are available. The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.
引用
收藏
页数:44
相关论文
共 39 条
  • [31] Evaluation of different CT maps for attenuation correction and segmentation in static 99mTc-MAA SPECT/CT for 90Y radioembolization treatment planning: A simulation study
    Lu, Zhonglin
    Chen, Gefei
    Lin, Kuan-Heng
    Wu, Tung-Hsin
    Mok, Greta S. P.
    [J]. MEDICAL PHYSICS, 2021, 48 (07) : 3842 - 3851
  • [32] Comparison of the 90Y-labelled glass microspheres liver radioembolisation dosimetry with the estimated dosimetry obtained from pre-treatment 99mTc-MAA SPECT images reconstructed with and without attenuation correction
    Demino, Laura
    Ferreira, Paulo
    Oliveira, Francisco P. M.
    Costa, Durval C.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2019, 7 (5-6) : 651 - 659
  • [33] Comparison of absorbed doses to the tumoral and non-tumoral liver in HCC patients undergoing 99mTc-MAA and 90Y-microspheres radioembolization
    Nut Noipinit
    Chanan Sukprakun
    Punnarai Siricharoen
    Kitiwat Khamwan
    [J]. Annals of Nuclear Medicine, 2024, 38 : 210 - 218
  • [34] Analysis of differences between 99mTc-MAA SPECT- and 90Y-microsphere PET-based dosimetry for hepatocellular carcinoma selective internal radiation therapy
    Kafrouni, Marilyne
    Allimant, Carole
    Fourcade, Marjolaine
    Vauclin, Sebastien
    Guiu, Boris
    Mariano-Goulart, Denis
    Ben Bouallegue, Faycal
    [J]. EJNMMI RESEARCH, 2019, 9 (1)
  • [35] Analysis of differences between 99mTc-MAA SPECT- and 90Y-microsphere PET-based dosimetry for hepatocellular carcinoma selective internal radiation therapy
    Marilyne Kafrouni
    Carole Allimant
    Marjolaine Fourcade
    Sébastien Vauclin
    Boris Guiu
    Denis Mariano-Goulart
    Fayçal Ben Bouallègue
    [J]. EJNMMI Research, 9
  • [36] Utility of pre-procedural [99mTc]TcMAA SPECT/CT Multicompartment Dosimetry for Treatment Planning of 90Y Glass microspheres in patients with Hepatocellular Carcinoma: comparison of anatomic versus [99mTc]TcMAA-based Segmentation
    Lam, Marnix
    Garin, Etienne
    Haste, Paul
    Denys, Alban
    Geller, Brian
    Kappadath, S. Cheenu
    Turkmen, Cuneyt
    Sze, Daniel Y.
    Alsuhaibani, Hamad Saleh
    Herrmann, Ken
    Maccauro, Marco
    Cantasdemir, Murat
    Dreher, Matthew
    Fowers, Kirk D.
    Gates, Vanessa
    Salem, Riad
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025, 52 (02) : 744 - 755
  • [37] Measure of 90Y-glass microspheres residue post-TARE using PET/CT and potential impact on tumor absorbed dose in comparison 99mTc-MAA SPECT/CT dosimetry
    Boughdad, Sarah
    Duran, Rafael
    Prior, John O.
    da Mota, Michael
    De Carvalho, Melanie Mendes
    Costes, Julien
    Firsova, Maria
    Gnesin, Silvano
    Schaefer, Niklaus
    [J]. EJNMMI REPORTS, 2024, 8 (01)
  • [38] Quantitative comparison of pre-therapy 99mTc-macroaggregated albumin SPECT/CT and post-therapy PET/MR studies of patients who have received intra-arterial radioembolization therapy with 90Y microspheres
    Knesaurek, Karin
    Tuli, Abbas
    Pasik, Sara D.
    Heiba, Sherif
    Kostakoglu, Lale
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 109 : 57 - 61
  • [39] PET/CT- Based Dosimetry in 90Y-Microsphere Selective Internal Radiation Therapy: Single Cohort Comparison With Pretreatment Planning on 99mTc-MAA Imaging and Correlation With Treatment Efficacy
    Song, Yoo Sung
    Paeng, Jin Chul
    Kim, Hyo-Cheol
    Chung, Jin Wook
    Cheon, Gi Jeong
    Chung, June-Key
    Lee, Dong Soo
    Kang, Keon Wook
    [J]. MEDICINE, 2015, 94 (23) : e945