EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres

被引:85
作者
Chiesa, Carlo [1 ]
Sjogreen-Gleisner, Katarina [2 ]
Walrand, Stephan [3 ]
Strigari, Lidia [4 ]
Flux, Glenn [5 ,6 ]
Gear, Jonathan [5 ,6 ]
Stokke, Caroline [7 ]
Gabina, Pablo Minguez [8 ]
Bernhardt, Peter [9 ,10 ]
Konijnenberg, Mark [11 ]
机构
[1] Fdn IRCCS Ist Nazl Tumori, Nucl Med Unit, Milan, Italy
[2] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[3] Catholic Univ Louvain, Nucl Med Mol Imaging Radiotherapy & Oncol Unit MI, IECR, Brussels, Belgium
[4] IRCCS Azienda Osped Univ Bologna, Med Phys Div, Bologna, Italy
[5] Royal Marsden Hosp, Joint Dept Phys, Sutton, Surrey, England
[6] Inst Canc Res, Sutton, Surrey, England
[7] Oslo Univ Hosp, Dept Diagnost Phys, Oslo, Norway
[8] Gurutzeta Cruces Univ Hosp, Dept Med Phys & Radiat Protect, Baracaldo, Spain
[9] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[10] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
[11] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
关键词
Radioembolization dosimetry; Tc-99m-MAA; Y-90; microspheres; Lung shunt; Liver dosimetry; Tumour dosimetry; PET; Prospective; retrospective dosimetry; SELECTIVE INTERNAL RADIOTHERAPY; VOXEL S-VALUES; HEPATOCELLULAR-CARCINOMA; GLASS MICROSPHERES; RADIATION-THERAPY; PARTITION MODEL; TC-99M-MACROAGGREGATED ALBUMIN; BREMSSTRAHLUNG SPECT/CT; IMAGE-RECONSTRUCTION; QUANTITATIVE SPECT;
D O I
10.1186/s40658-021-00394-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in Y-90 microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of Tc-99m albumin macro-aggregates (MAA) and Y-90 microsphere biodistribution is also assumed. The large observed discrepancies in some patients between Tc-99m-MAA predictions and actual Y-90 microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments. Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected Tc-99m-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and Y-90 TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected Tc-99m-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative Y-90 bremsstrahlung SPECT can be used if dedicated correction methods are available. The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.
引用
收藏
页数:44
相关论文
共 39 条
  • [21] Optimization of 99mTc-MAA SPECT/CT Imaging for 90Y Radioembolization Using a 3D-Printed Phantom
    Ungania, Sara
    D'Arienzo, Marco
    Nocentini, Sandro
    D'Andrea, Marco
    Bruzzaniti, Vicente
    Marconi, Raffaella
    Mezzenga, Emilio
    Cassano, Bartolomeo
    Infusino, Erminia
    Guerrisi, Antonino
    Soriani, Antonella
    Strigari, Lidia
    APPLIED SCIENCES-BASEL, 2022, 12 (19):
  • [22] Predictive Value of [99mTc]-MAA-Based Dosimetry in Hepatocellular Carcinoma Patients Treated with [90Y]-TARE: A Single-Center Experience
    Doppler, Michael
    Reincke, Marlene
    Bettinger, Dominik
    Vogt, Katharina
    Weiss, Jakob
    Schultheiss, Michael
    Uller, Wibke
    Verloh, Niklas
    Goetz, Christian
    DIAGNOSTICS, 2023, 13 (14)
  • [23] Planning dosimetry for90Y radioembolization with glass microspheres: Evaluating the fidelity of99mTc-MAA and partition model predictions
    Thomas, M. Allan
    Mahvash, Armeen
    Abdelsalam, Mohamed
    Kaseb, Ahmed O.
    Kappadath, S. Cheenu
    MEDICAL PHYSICS, 2020, 47 (10) : 5333 - 5342
  • [24] Quantitative Comparison of Yttrium-90 (90Y)-Microspheres and Technetium-99m (99mTc)-Macroaggregated Albumin SPECT Images for Planning 90Y Therapy of Liver Cancer
    Knesaurek, Karin
    Machac, Josef
    Muzinic, Michael
    DaCosta, Maria
    Zhang, Zhuangyu
    Heiba, Sherif
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (03) : 253 - 261
  • [25] Prognostic Utility of 90Y Radioembolization Dosimetry Based on Fusion 99mTc-Macroaggregated Albumin-99mTc-Sulfur Colloid SPECT
    Lam, Marnix G. E. H.
    Goris, Michael L.
    Iagaru, Andrei H.
    Mittra, Erik S.
    Louie, John D.
    Sze, Daniel Y.
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (12) : 2055 - 2061
  • [26] Absorbed dose to lesion and clinical outcome after liver radioembolization with 90Y microspheres: a case report of PET-based dosimetry
    D'Arienzo, Marco
    Filippi, Luca
    Chiaramida, Paola
    Chiacchiararelli, Laura
    Cianni, Roberto
    Salvatori, Rita
    Scopinaro, Francesco
    Bagni, Oreste
    ANNALS OF NUCLEAR MEDICINE, 2013, 27 (07) : 676 - 680
  • [27] Comparison of absorbed doses to the tumoral and non-tumoral liver in HCC patients undergoing 99mTc-MAA and 90Y-microspheres radioembolization
    Noipinit, Nut
    Sukprakun, Chanan
    Siricharoen, Punnarai
    Khamwan, Kitiwat
    ANNALS OF NUCLEAR MEDICINE, 2024, 38 (03) : 210 - 218
  • [28] Lung shunt fraction calculation using 99mTc-MAA SPECT/CT imaging for 90Y microsphere selective internal radiation therapy of liver tumors
    Georgiou, Mike F.
    Kuker, Russ A.
    Studenski, Matthew T.
    Ahlman, Preeti P.
    Witte, Megan
    Portelance, Lorraine
    EJNMMI RESEARCH, 2021, 11 (01)
  • [29] Technical note: simultaneous 90Y and 99mTc-MAA injection for two-stage selective internal radiation therapy (SIRT) of liver metastases
    Eftekhari, Arash
    Worsley, Daniel
    Klass, Darren
    Liu, David M.
    TRANSLATIONAL CANCER RESEARCH, 2014, 3 (02) : 138 - 145
  • [30] Absorbed dose to lesion and clinical outcome after liver radioembolization with 90Y microspheres: a case report of PET-based dosimetry
    Marco D’Arienzo
    Luca Filippi
    Paola Chiaramida
    Laura Chiacchiararelli
    Roberto Cianni
    Rita Salvatori
    Francesco Scopinaro
    Oreste Bagni
    Annals of Nuclear Medicine, 2013, 27 : 676 - 680