EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres

被引:92
作者
Chiesa, Carlo [1 ]
Sjogreen-Gleisner, Katarina [2 ]
Walrand, Stephan [3 ]
Strigari, Lidia [4 ]
Flux, Glenn [5 ,6 ]
Gear, Jonathan [5 ,6 ]
Stokke, Caroline [7 ]
Gabina, Pablo Minguez [8 ]
Bernhardt, Peter [9 ,10 ]
Konijnenberg, Mark [11 ]
机构
[1] Fdn IRCCS Ist Nazl Tumori, Nucl Med Unit, Milan, Italy
[2] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[3] Catholic Univ Louvain, Nucl Med Mol Imaging Radiotherapy & Oncol Unit MI, IECR, Brussels, Belgium
[4] IRCCS Azienda Osped Univ Bologna, Med Phys Div, Bologna, Italy
[5] Royal Marsden Hosp, Joint Dept Phys, Sutton, Surrey, England
[6] Inst Canc Res, Sutton, Surrey, England
[7] Oslo Univ Hosp, Dept Diagnost Phys, Oslo, Norway
[8] Gurutzeta Cruces Univ Hosp, Dept Med Phys & Radiat Protect, Baracaldo, Spain
[9] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[10] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
[11] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
关键词
Radioembolization dosimetry; Tc-99m-MAA; Y-90; microspheres; Lung shunt; Liver dosimetry; Tumour dosimetry; PET; Prospective; retrospective dosimetry; SELECTIVE INTERNAL RADIOTHERAPY; VOXEL S-VALUES; HEPATOCELLULAR-CARCINOMA; GLASS MICROSPHERES; RADIATION-THERAPY; PARTITION MODEL; TC-99M-MACROAGGREGATED ALBUMIN; BREMSSTRAHLUNG SPECT/CT; IMAGE-RECONSTRUCTION; QUANTITATIVE SPECT;
D O I
10.1186/s40658-021-00394-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in Y-90 microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of Tc-99m albumin macro-aggregates (MAA) and Y-90 microsphere biodistribution is also assumed. The large observed discrepancies in some patients between Tc-99m-MAA predictions and actual Y-90 microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments. Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected Tc-99m-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and Y-90 TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected Tc-99m-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative Y-90 bremsstrahlung SPECT can be used if dedicated correction methods are available. The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.
引用
收藏
页数:44
相关论文
共 116 条
[41]   Clinical impact of 99mTc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with 90Y-loaded microspheres [J].
Garin, Etienne ;
Rolland, Yan ;
Laffont, Sophie ;
Edeline, Julien .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (03) :559-575
[42]   Effectiveness of quantitative MAA SPECT/CT for the definition of vascularized hepatic volume and dosimetric approach: phantom validation and clinical preliminary results in patients with complex hepatic vascularization treated with yttrium-90-labeled microspheres [J].
Garin, Etienne ;
Lenoir, Laurence ;
Rolland, Yan ;
Laffont, Sophie ;
Pracht, Marc ;
Mesbah, Habiba ;
Poree, Philippe ;
Ardisson, Valerie ;
Bourguet, Patrick ;
Clement, Bruno ;
Boucher, Eveline .
NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (12) :1245-1255
[43]   Internal Pair Production of 90Y Permits Hepatic Localization of Microspheres Using Routine PET: Proof of Concept [J].
Gates, Vanessa L. ;
Esmail, Abdulredha A. H. ;
Marshall, Karen ;
Spies, Stewart ;
Salem, Riad .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (01) :72-76
[44]   EANM practical guidance on uncertainty analysis for molecular radiotherapy absorbed dose calculations [J].
Gear, Jonathan I. ;
Cox, Maurice G. ;
Gustafsson, Johan ;
Gleisner, Katarina Sjoegreen ;
Murray, Iain ;
Glatting, Gerhard ;
Konijnenberg, Mark ;
Flux, Glenn D. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (13) :2456-2474
[45]   Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT [J].
Gear, Jonathan I. ;
Cummings, Craig ;
Craig, Allison J. ;
Divoli, Antigoni ;
Long, Clive D. C. ;
Tapner, Michael ;
Flux, Glenn D. .
EJNMMI PHYSICS, 2016, 3 (01)
[46]   EANM procedure guideline for the treatment of liver cancer and liver metastases with intra-arterial radioactive compounds [J].
Giammarile, Francesco ;
Bodei, Lisa ;
Chiesa, Carlo ;
Flux, Glenn ;
Forrer, Flavio ;
Kraeber-Bodere, Francoise ;
Brans, Boudewijn ;
Lambert, Bieke ;
Konijnenberg, Mark ;
Borson-Chazot, Francoise ;
Tennvall, Jan ;
Luster, Markus .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (07) :1393-1406
[47]   Systematic review of lung shunt fraction quantification comparing SPECT/CT and planar scintigraphy for yttrium 90 radioembolization planning [J].
Gill, Harkanwar ;
Hiller, Jay .
CLINICAL AND TRANSLATIONAL IMAGING, 2021, 9 (02) :181-188
[48]   Partition Model Based 99mTc-MAA SPECT/CT Predictive Dosimetry Compared with 90Y TOF PET/CT Posttreatment Dosimetry in Radioembolization of Hepatocellular Carcinoma: A Quantitative Agreement Comparison [J].
Gnesin, Silvano ;
Canetti, Laurent ;
Adib, Salim ;
Cherbuin, Nicolas ;
Monteiro, Marina Silva ;
Bize, Pierre ;
Denys, Alban ;
Prior, John O. ;
Baechler, Sebastien ;
Boubaker, Ariane .
JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (11) :1672-1678
[49]   Correlation of Technetium-99m Macroaggregated Albumin and Yttrium-90 Glass Microsphere Biodistribution in Hepatocellular Carcinoma: A Retrospective Review of Pretreatment Single Photon Emission CT and Posttreatment Positron Emission Tomography/CT [J].
Haste, Paul ;
Tann, Mark ;
Persohn, Scott ;
LaRoche, Thomas ;
Aaron, Vasantha ;
Mauxion, Thibault ;
Chauhan, Nikhil ;
Dreher, Matthew R. ;
Johnson, Matthew S. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (05) :722-730
[50]   Autoradiography and biopsy measurements of a resected hepatocellular carcinoma treated with 90 yttrium radioembolization demonstrate large absorbed dose heterogeneities [J].
Hemmingsson, Jens ;
Hogberg, Jonas ;
Molne, Johan ;
Svensson, Johanna ;
Gjertsson, Peter ;
Rizell, Magnus ;
Henrikson, Olof ;
Bernhardt, Peter .
ADVANCES IN RADIATION ONCOLOGY, 2018, 3 (03) :439-446