Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers

被引:34
作者
Sadaf, Arifa [1 ]
Crystal, Pavel [1 ]
Scaranelo, Anabel [2 ]
Helbich, Thomas [3 ]
机构
[1] Mt Sinai Hosp, Dept Med Imaging, Toronto, ON M5G 1X5, Canada
[2] Princess Margaret Hosp, Dept Med Imaging, Toronto, ON M5G 2M9, Canada
[3] Med Univ Vienna, Gen Hosp Vienna, A-1090 Vienna, Austria
关键词
Mammography; Computer-assisted detection; Breast cancer; SCREENING MAMMOGRAPHY; DETECTION SYSTEM; FILM MAMMOGRAPHY; DETECTION CAD; SENSITIVITY; APPEARANCE; PROGRAM; IMPACT;
D O I
10.1016/j.ejrad.2009.08.024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this retrospective study was to evaluate performance of computer-aided detection (CAD) with full-field digital mammography (FFDM) in detection of breast cancers. Materials and Methods: CAD was retrospectively applied to standard mammographic views of 127 cases with biopsy proven breast cancers detected with FFDM (Senographe 2000, GE Medical Systems). CAD sensitivity was assessed in total group of 127 cases and for subgroups based on breast density, mammographic lesion type, mammographic lesion size, histopathology and mode of presentation. Results: Overall CAD sensitivity was 91% (115 of 127 cases). There were no statistical differences (p > 0.1) in CAD detection of cancers in dense breasts 90% (53/59) versus non-dense breasts 91% (62/68). There was statistical difference (p < 0.05) in CAD detection of cancers that appeared mammographically as micro-calcifications only versus other mammographic manifestations. CAD detected 100% (44/44) of cancers manifesting as microcalcifications, 89% (47/53) as no-calcified masses or asymmetries, 88% (14/16) as masses with associated calcifications, and 71% (10/14) as architectural distortions. CAD sensitivity for cancers 1-10 mm was 84% (38/45); 11-20 mm 93% (55/59); and > 20 mm 97% (22/23). Conclusion: CAD applied to FFDM showed 100% sensitivity in identifying cancers manifesting as microcalcifications only and high sensitivity 86% (71/83) for other mammographic appearances of cancer. Sensitivity is influenced by lesion size. CAD in FFDM is an adjunct helping radiologist in early detection of breast cancers. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:457 / 461
页数:5
相关论文
共 31 条
[1]  
[Anonymous], 2003, BREAST IM REP DAT SY
[2]   Computer-aided detection in direct digital full-field mammography: initial results [J].
Baum, F ;
Fischer, U ;
Obenauer, S ;
Grabbe, E .
EUROPEAN RADIOLOGY, 2002, 12 (12) :3015-3017
[3]   Digital and screen-film mammography: Comparison of image acquisition and interpretation times [J].
Berns, EA ;
Hendrick, RE ;
Solari, M ;
Barke, L ;
Reddy, D ;
Wolfman, J ;
Segal, L ;
DeLeon, P ;
Benjamin, S ;
Willis, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) :38-41
[4]   Computer-aided detection with screening mammography in a university hospital setting [J].
Birdwell, RL ;
Bandodkar, P ;
Ikeda, DM .
RADIOLOGY, 2005, 236 (02) :451-457
[5]   CAD in questions/answers Review of the literature [J].
Boyer, Bruno ;
Balleyguier, Corinne ;
Granat, Olivier ;
Pharaboz, Christian .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 69 (01) :24-33
[6]   Does computer-aided detection (CAD) contribute to the performance of digital mammography in a self-referred population? [J].
Brancato, Beniamino ;
Houssami, Nehmat ;
Francesca, Damiana ;
Bianchi, Simonetta ;
Risso, Gabriella ;
Catarzi, Sandra ;
Taschini, Renzo ;
Del Turco, Marco Rosselli ;
Ciatto, Stefano .
BREAST CANCER RESEARCH AND TREATMENT, 2008, 111 (02) :373-376
[7]   Evaluation of breast cancer with a computer-aided detection system by mammographic appearance and histopathology [J].
Brem, RF ;
Rapelyea, JA ;
Zisman, G ;
Hoffmeister, JW ;
DeSimio, MP .
CANCER, 2005, 104 (05) :931-935
[8]   A computer-aided detection system for the evaluation of breast cancer by mammographic appearance and lesion size [J].
Brem, RF ;
Hoffmeister, JW ;
Zisman, G ;
DeSimio, MP ;
Rogers, SK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (03) :893-896
[9]   Impact of breast density on computer-aided detection for breast cancer [J].
Brem, RF ;
Hoffmeister, JW ;
Rapelyea, JA ;
Zisman, G ;
Mohtashemi, K ;
Jindal, G ;
DiSimio, MP ;
Rogers, SK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) :439-444
[10]   Improvement in sensitivity of screening mammography with computer-aided detection: A multiinstitutional trial [J].
Brem, RF ;
Baum, J ;
Lechner, M ;
Kaplan, S ;
Souders, S ;
Naul, LG ;
Hoffmeister, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (03) :687-693