Investigation on electromagnetic microactuator and its application in micro-electro-mechanical system (MEMS)

被引:7
作者
Su, Yufeng [1 ]
Chen, Wenyuan [2 ]
机构
[1] Zhengzhou Univ, Sch Mech Engn, Zhengzhou, Henan Province, Peoples R China
[2] Shanghai Jiao Tong Univ, Res Inst Micronano Sci & Technol, Shanghai, Peoples R China
来源
2007 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS I-V, CONFERENCE PROCEEDINGS | 2007年
关键词
microactuator; magnetic; bidirectional; polydimethyl siloxane (PDMS); electroplating;
D O I
10.1109/ICMA.2007.4304082
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, we presented the design, fabrication and testing of a novel bidirectional magnetic microactuator. The microactuator. is composed of an integrated planar coil and a flexible polydimethyl siloxane (PDMS) diaphragm with embedded CoNiMnP-based permanent magnet arrays. There is a 7x7 array of magnets in a unit. The PDMS. diaphragm is 2mmx2mmx41 mu m and the magnet post is 50 mu mx50 mu mx20 mu m. Computer simulation is applied to optimize the geometrical parameters. Electro-plating under external magnetic field is carried out to improve the magnetic properties of the electroplated magnet, including coercivity, remanence and magnetic energy and so on. The measured maximum coercivity, remanence and maximum magnetic energy are 26230e(208.73kA/m), 0.2T(2000G) and 10.15kJ/m(3) with the magnet post respectively. Moreover,the deflection of the PDMS membrane is proportional to the exciting current. In a case of 0.35A current, the maximum deflection of the membrane is 45 mu m. Adjusting the electroplating mold results in the variation of the electroplated structure, thus the calibration of the microactuaor. Due to the biomedical compatibility and simplicity of the fabrication, the flexible membrane-based microactuator is. potential to be used in MEMS (Micro-Electro-Mechanical System) applications, such as micropump and optical switch.
引用
收藏
页码:3250 / +
页数:2
相关论文
共 15 条
[1]  
BRANEBJEREG J, IEEE MEMS 92 TRAVEMU, P6
[2]   Numerical simulation and optimization of planar electromagnetic actuators [J].
Feustel, A ;
Krusemark, O ;
Muller, J .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 70 (03) :276-282
[3]   Fabrication and test of a thermopneumatic micropump with a corrugated p plus diaphragm [J].
Jeong, OC ;
Yang, SS .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 83 (1-3) :249-255
[4]   Micro magnetic silicone elastomer membrane actuator [J].
Khoo, M ;
Liu, C .
SENSORS AND ACTUATORS A-PHYSICAL, 2001, 89 (03) :259-266
[5]   The dynamic micropump driven with a screen printed PZT actuator [J].
Koch, M ;
Evans, AGR ;
Brunnschweiler, A .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1998, 8 (02) :119-122
[6]  
LIAKOPOULOS TM, 1996, IEEE MEMS 96 SAN DIE, P79
[7]   Fabrication of Nd-Fe-B thick-film magnets by high-speed PLD method [J].
Nakano, M ;
Katoh, R ;
Fukunaga, H ;
Tutumi, S ;
Yamashita, F .
IEEE TRANSACTIONS ON MAGNETICS, 2003, 39 (05) :2863-2865
[8]   An electrochemical microactuator: Principle and first results [J].
Neagu, CR ;
Gardeniers, JGE ;
Elwenspoek, M ;
Kelly, JJ .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1996, 5 (01) :2-9
[9]   Electroplated hard magnetic material and its application in microelectromechanical systems [J].
Su, YF ;
Wang, H ;
Ding, GF ;
Cui, F ;
Zhang, WP ;
Chen, WY .
IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (12) :4380-4383
[10]  
Timoshenko S, 1977, THEORY PLATES SHELLS