Flow amperometric uric acid biosensors based on different enzymatic mini-reactors: A comparative study of uricase immobilization

被引:22
作者
Tvorynska, Sofiia [1 ,2 ]
Barek, Jiri [1 ]
Josypcuk, Bohdan [2 ]
机构
[1] Charles Univ Prague, UNESCO, Fac Sci, Lab Environm Electrochem,Dept Analyt Chem, Hlavova,2030-8, Prague 12843 2, Czech Republic
[2] CAS, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2021年 / 344卷
关键词
Uric acid; Uricase; Amperometric biosensor; Enzymatic mini-reactor; Flow injection analysis; SILVER SOLID AMALGAM; CARBON-FELT; ELECTROCHEMICAL BIOSENSOR; TUBULAR DETECTOR; ELECTRODE; CONSTRUCTION; GLUCOSE; SILICA; SERUM; BLUE;
D O I
10.1016/j.snb.2021.130252
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This is the first report of a novel strategy for uric acid (UA) determination via newly developed highly stable flow biosensors based on different enzymatic mini-reactors in combination with a four-electron reduction of the consumed oxygen. The design of the biosensors provides a spatial separation of the detection (working electrode) and biorecognition (uricase-based mini-reactor) part. To prepare the most efficient enzymatic mini-reactor, a comparative study focused on three different techniques of the covalent uricase immobilization at two kinds of mesoporous silica powders (SBA-15 and MCM-41) and the physical enzyme adsorption at four types of carbonaceous powders (glassy carbon, graphite, Starbon (R) 300, and Starbon (R) 800) has been performed. All investigations were carried out for two kinds of uricase: from Candida sp. (UOx(c)) and from Bacillus fastidiosus (UOx(b)) to estimate the influence of uricase source. The flow-through cell with tubular detector of silver solid amalgam was used for amperometric monitoring of four-electron oxygen reduction at the highly negative po-tential (-1100 mV vs. SCE). It was found that the developed UA biosensors responses are strongly dependent on the enzyme immobilization strategy. UOx(c) bounded to glassy carbon by physical adsorption has provided good results in terms of sensitivity, stability, and repeatability for UA determination. The biosensor with the mini-reactor based on the covalent immobilization of UOx(b) at glutaraldehyde activated -NH2 functionalized MCM-41 has shown extremely high stability (more than 1 year) and reusability (at least 600 measurements) The biosensor's practical applicability has been tested by successful determination of UA in human urine.
引用
收藏
页数:13
相关论文
共 68 条
  • [1] Fabrication of highly sensitive uric acid biosensor based on directly grown ZnO nanosheets on electrode surface
    Ahmad, Rafiq
    Tripathy, Nirmalya
    Jang, Na Keum
    Khang, Gilson
    Hahn, Yoon-Bong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 146 - 151
  • [2] An amperometric uric acid biosensor based on Bis[sulfosuccinimidyl] suberate crosslinker/3-aminopropyltriethoxysilane surface modified ITO glass electrode
    Ahuja, Tarushee
    Rajesh
    Kumar, Devendra
    Tanwar, Vinod Kumar
    Sharma, Vikash
    Singh, Nahar
    Biradar, Ashok M.
    [J]. THIN SOLID FILMS, 2010, 519 (03) : 1128 - 1134
  • [3] Reagentless uric acid biosensor based on Ni microdiscs-loaded NiO thin film matrix
    Arora, Kashima
    Tomar, Monika
    Gupta, Vinay
    [J]. ANALYST, 2014, 139 (18) : 4606 - 4612
  • [4] Novel support for enzyme immobilization prepared by chemical activation with cysteine and glutaraldehyde
    Bezbradica, Dejan I.
    Mateo, Cesar
    Guisan, Jose M.
    [J]. JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2014, 102 : 218 - 224
  • [5] An Amperomertic Uric Acid Biosensor Based on Immobilization of Uricase onto Polyaniline-multiwalled Carbon Nanotube Composite Film
    Bhambi, Manu
    Sumana, G.
    Malhotra, B. D.
    Pundir, C. S.
    [J]. ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2010, 38 (04): : 178 - 185
  • [6] Determination of L-Lactic Acid Content in Foods by Enzyme-Based Amperometric Bioreactor
    Bori, Zsuzsanna
    Csiffary, Gabor
    Virag, Diana
    Toth-Markus, Marianna
    Kiss, Attila
    Adanyi, Nora
    [J]. ELECTROANALYSIS, 2012, 24 (01) : 158 - 164
  • [7] Construction of an Uricase Nanoparticles Modified Au Electrode for Amperometric Determination of Uric Acid
    Chauhan, Nidhi
    Kumar, Arun
    Pundir, C. S.
    [J]. APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2014, 174 (04) : 1683 - 1694
  • [8] An amperometric uric acid biosensor based on multiwalled carbon nanotube-gold nanoparticle composite
    Chauhan, Nidhi
    Pundir, Chandra Shekhar
    [J]. ANALYTICAL BIOCHEMISTRY, 2011, 413 (02) : 97 - 103
  • [9] An Electrochemical Biosensor with Uricase Immobilized on Functionalized Gold Coated Copper Wire Electrode for Urinary Uric Acid Assay
    Cheng, Cheanyeh
    Kao, Chi-Ying
    [J]. ELECTROANALYSIS, 2016, 28 (04) : 695 - 703
  • [10] NEW TYPE BIOSENSOR FOR THE DETECTION OF PESTICIDES, BASED ON THE INHIBITION OF ACETYLCHOLINESTERASE
    Csiffary, G.
    Nagy, P.
    Kiss, A.
    Adanyi, N.
    [J]. ACTA ALIMENTARIA, 2013, 42 (01) : 79 - 90