Multidetector CT urography: experimental analysis of radiation dose reduction in an animal model

被引:21
|
作者
Kemper, Joern [1 ]
Regier, Marc [1 ]
Bansmann, Paul M. [1 ]
Begemann, Philipp G. C. [1 ]
Stork, Alexander [1 ]
Nagel, Hans Dieter [1 ]
Adam, Gerhard [1 ]
Nolte-Ernsting, Claus [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Ctr Diagnost, Int Radiol, D-20246 Hamburg, Germany
关键词
computed tomography; urography; ureter; Ct; dose reduction; radiation; exposure to personnel and patients;
D O I
10.1007/s00330-006-0565-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the possibility of reducing X-ray exposure during multidetector CT urography (MDCTU) considering image quality using a porcine model. MDCTU was performed in eight healthy pigs. Scanning was conducted using a gradual reduction of the tube current-time product at 120 kV [200-20 mAs (eff.) in ten steps]. Three blinded observers independently evaluated the image data for anatomic detail, subjective image quality, and subjective image noise. Overall image quality was compared to milliampere-second settings and radiation dose. Objective noise measurements were assessed. Noise measurements in patients were also performed to verify the comparabilty of the animal model. Adequate image quality allowing for detailed visualization of the upper urinary tract was obtained when the tube current-time product was decreased to 70 eff. mAs at 120 kV. Image noise did not impair image quality to a relevant degree using these parameters. There was high agreement among the observers (ICC=0.95). In the animal experiments, reduced-dose MDCTU produced good image quality. A maximum current-time product reduction to 70 eff. mAs at 120 kV (CTDIvol=5.3 mGy) proved to be feasible, thereby offering an advantageous dosage reduction. The study provides a basis for the development of reduced-dose MDCTU protocols in humans.
引用
收藏
页码:2318 / 2324
页数:7
相关论文
共 50 条
  • [41] A systematic review of radiation dose associated with different generations of multidetector CT coronary angiography
    Sabarudin, Akmal
    Sun, Zhonghua
    Ng, Kwan-Hoong
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (01) : 5 - 17
  • [42] Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit
    Tack, Denis
    Jahnen, Andreas
    Kohler, Sarah
    Harpes, Nico
    De Maertelaer, Viviane
    Back, Carlo
    Gevenois, Pierre Alain
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 169 - 175
  • [43] Radiation dose reduction in parasinus CT by spectral shaping
    May, Matthias S.
    Brand, Michael
    Lell, Michael M.
    Sedlmair, Martin
    Allmendinger, Thomas
    Uder, Michael
    Wuest, Wolfgang
    NEURORADIOLOGY, 2017, 59 (02) : 169 - 176
  • [44] Experimental Study and Optimization of Scan Parameters That Influence Radiation Dose in Temporal Bone High-Resolution Multidetector Row CT
    Niu, Y. T.
    Olszewski, M. E.
    Zhang, Y. X.
    Liu, Y. F.
    Xian, J. F.
    Wang, Z. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1783 - 1788
  • [45] Study of the radiation dose reduction capability of a CT reconstruction algorithm - LCD performance assessment using mathematical model observers
    Fan, Jiahua
    Tseng, Hsin-Wu
    Kupinski, Matthew
    Cao, Guangzhi
    Sainath, Paavana
    Hsieh, Jiang
    MEDICAL IMAGING 2013: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2013, 8673
  • [46] CT radiation dose reduction in patients with total hip arthroplasties using model-based iterative reconstruction and orthopaedic metal artefact reduction
    Wellenberg, Ruud H. H.
    van Osch, Jochen A. C.
    Boelhouwers, Henk J.
    Edens, Mireille A.
    Streekstra, Geert J.
    Ettema, Harmen B.
    Boomsma, Martijn F.
    SKELETAL RADIOLOGY, 2019, 48 (11) : 1775 - 1785
  • [47] Radiation Dose Reduction in Paranasal Sinus CT Using Model-Based Iterative Reconstruction
    Hoxworth, J. M.
    Lal, D.
    Fletcher, G. P.
    Patel, A. C.
    He, M.
    Paden, R. G.
    Hara, A. K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (04) : 644 - 649
  • [48] Radiation dose evaluation in multidetector-row CT imaging for acute stroke with an anthropomorphic phantom
    Yamauchi-Kawara, C.
    Fujii, K.
    Aoyama, T.
    Yamauchi, M.
    Koyama, S.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (996) : 1029 - 1041
  • [49] Image optimization and reduction of radiation dose in CT of the paranasal sinuses
    Davoudi, Mohammad
    Lotfian Ahangarkolaei, Shaghayegh
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (04):
  • [50] Radiation Dose Reduction in Kidney Stone CT: A Randomized, Facility-Based Intervention
    Moore, Christopher L.
    Bhargavan-Chatfield, Mythreyi
    Shaw, Melissa M.
    Weisenthal, Karrin
    Kalra, Mannudeep K.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2021, 18 (10) : 1394 - 1404