Multidetector CT urography: experimental analysis of radiation dose reduction in an animal model

被引:21
|
作者
Kemper, Joern [1 ]
Regier, Marc [1 ]
Bansmann, Paul M. [1 ]
Begemann, Philipp G. C. [1 ]
Stork, Alexander [1 ]
Nagel, Hans Dieter [1 ]
Adam, Gerhard [1 ]
Nolte-Ernsting, Claus [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Ctr Diagnost, Int Radiol, D-20246 Hamburg, Germany
关键词
computed tomography; urography; ureter; Ct; dose reduction; radiation; exposure to personnel and patients;
D O I
10.1007/s00330-006-0565-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the possibility of reducing X-ray exposure during multidetector CT urography (MDCTU) considering image quality using a porcine model. MDCTU was performed in eight healthy pigs. Scanning was conducted using a gradual reduction of the tube current-time product at 120 kV [200-20 mAs (eff.) in ten steps]. Three blinded observers independently evaluated the image data for anatomic detail, subjective image quality, and subjective image noise. Overall image quality was compared to milliampere-second settings and radiation dose. Objective noise measurements were assessed. Noise measurements in patients were also performed to verify the comparabilty of the animal model. Adequate image quality allowing for detailed visualization of the upper urinary tract was obtained when the tube current-time product was decreased to 70 eff. mAs at 120 kV. Image noise did not impair image quality to a relevant degree using these parameters. There was high agreement among the observers (ICC=0.95). In the animal experiments, reduced-dose MDCTU produced good image quality. A maximum current-time product reduction to 70 eff. mAs at 120 kV (CTDIvol=5.3 mGy) proved to be feasible, thereby offering an advantageous dosage reduction. The study provides a basis for the development of reduced-dose MDCTU protocols in humans.
引用
收藏
页码:2318 / 2324
页数:7
相关论文
共 50 条
  • [21] Image Quality in Multidetector CT of Paranasal Sinuses: Potential of Dose Reduction Using an Adaptive Post-Processing Filter
    Kropil, P.
    Cohnen, M.
    Andersen, K.
    Heinen, W.
    Stegmann, V.
    Modder, U.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (11): : 973 - 978
  • [22] Radiation dose from multidetector row CT imaging for acute stroke
    Anisa Mnyusiwalla
    Richard I. Aviv
    Sean P. Symons
    Neuroradiology, 2009, 51 : 635 - 640
  • [23] Dose reduction in oncological staging multidetector CT: effect of iterative reconstruction
    Karpitschka, M.
    Augart, D.
    Becker, H-C
    Reiser, M.
    Graser, A.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1021)
  • [24] Spatial Resolution and Radiation Dose of a 64-MDCT Scanner Compared with Published CT Urography Protocols
    Vrtiska, Terri J.
    Hartman, Robert P.
    Kofler, James M.
    Bruesewitz, Michael R.
    King, Bernard F.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : 941 - 948
  • [25] Split-Bolus Spectral Multidetector CT of the Pancreas: Assessment of Radiation Dose and Tumor Conspicuity
    Brook, Olga R.
    Gourtsoyianni, Sofia
    Brook, Alexander
    Siewert, Bettina
    Kent, Tara
    Raptopoulos, Vassilios
    RADIOLOGY, 2013, 269 (01) : 139 - 148
  • [26] Radiaton dose and dose reduction in multidetector row CT (MDCT) [Strahlendosis und möglichkeiten zur dosisreduktion in der mehrschicht-CT]
    Herzog P.
    Jakobs T.F.
    Wintersperger B.J.
    Nikolaou K.
    Becker C.R.
    Reiser M.F.
    Der Radiologe, 2002, 42 (9): : 691 - 696
  • [27] Radiation dose reduction in paediatric cranial CT
    C.-Y. Chan
    Yiu-chung Wong
    Luen-fai Chau
    S.-K. Yu
    Po-chung Lau
    Pediatric Radiology, 1999, 29 : 770 - 775
  • [28] Radiation dose reduction in CT coronary angiography
    Shapiro B.P.
    Young P.M.
    Kantor B.
    Choe Y.H.
    McCollough C.H.
    Gerber T.C.
    Current Cardiology Reports, 2010, 12 (1) : 59 - 67
  • [29] Radiation dose reduction in chest CT: A review
    Kubo, Takeshi
    Lin, Pei-Jan Paul
    Stiller, Wolfram
    Takahashi, Masaya
    Kauczor, Hans-Ulrich
    Ohno, Yoshiharu
    Hatabu, Hiroto
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) : 335 - 343
  • [30] COMPARISON OF RADIATION DOSE AND IMAGE QUALITY IN HEAD CT SCANS AMONG MULTIDETECTOR CT SCANNERS
    Abuzaid, Mohamed M.
    Elshami, Wiam
    Tekin, H. O.
    Sulieman, Abdelmoneim
    Bradley, D. A.
    RADIATION PROTECTION DOSIMETRY, 2021, 196 (1-2) : 10 - 16