PVC membrane and coated graphite potentiometric sensors based on dibenzo-21-crown-7 for selective determination of rubidium ions

被引:14
作者
Shamsipur, M [1 ]
Alizadeh, K
Hosseini, M
Mousavi, MF
机构
[1] Razi Univ, Dept Chem, Kermanshah, Iran
[2] Taebiat Modarres Univ, Dept Chem, Tehran, Iran
[3] Univ Tehran, Dept Chem, Tehran, Iran
关键词
Rb+-selective electrodes; PVC membrane; dibenzo-21-crown-7; potentiometry;
D O I
10.1081/AL-200050163
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solution studies on the binding properties of dibenzo-21 -crown-7 (DB21 C7) with alkali metal and ammonium ions revealed the occurrence of a selective 1:1 complexation of the ligand with Rb+ ion. Consequently, DB21C7 was used as a suitable ionophore for the preparation of novel polymeric membrane (PME) and coated graphite (CGE) Rb+-selective electrodes. The electrodes exhibit near-Nernstian behavior for Rb+-ions over concentration ranges of 5.0 x 10(-5) to 1.0 x 10(-1) M for PME and 1.0 X 10(-5) to 5.0 x 10(-2) M for CGE with limits of detection of 1.5 x 10(-5) M for PME and 7.1 X 10(-6)M for CGE. The proposed potentiometric sensors possess response times of < 40 s and can be used for at least 7 weeks without observing any deviation. The electrodes revealed comparatively good selectivities with respect to many alkali, alkaline earth, transition, and heavy metal ions. The working pH range of the electrodes is 3.5-8.0.
引用
收藏
页码:573 / 588
页数:16
相关论文
共 36 条
  • [31] Dibenzo-18-crown-6-based carbon paste sensors for the nanomolar potentiometric determination of daclatasvir dihydrochloride: An anti-HCV drug and a potential candidate for treatment of SARS-CoV-2
    Ahmed, Yomna M.
    Badawy, Sayed S.
    Abdel-Haleem, Fatehy M.
    MICROCHEMICAL JOURNAL, 2022, 177
  • [32] Novel coated-graphite membrane sensor based on N,N′-dimethylcyanodiaza-18-crown-6 for the determination of ultra-trace amounts of lead
    Ganjali, MR
    Hosseini, M
    Basiripour, F
    Javanbakht, M
    Hashemi, OR
    Rastegar, MF
    Shamsipur, M
    Buchanen, GW
    ANALYTICA CHIMICA ACTA, 2002, 464 (02) : 181 - 186
  • [33] Rapid automated method for on-site determination of sulfadiazine in fish farming: a stainless steel veterinary syringe coated with a selective membrane of PVC serving as a potentiometric detector in a flow-injection-analysis system
    Almeida, S. A. A.
    Amorim, L. R.
    Heitor, A. H.
    Montenegro, M. C. B. S. M.
    Barbosa, J.
    Sa, L. C.
    Sales, M. G. F.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (10) : 3355 - 3365
  • [34] Rapid automated method for on-site determination of sulfadiazine in fish farming: a stainless steel veterinary syringe coated with a selective membrane of PVC serving as a potentiometric detector in a flow-injection-analysis system
    S. A. A. Almeida
    L. R. Amorim
    A. H. Heitor
    M. C. B. S. M. Montenegro
    J. Barbosa
    L. C. Sá
    M. G. F. Sales
    Analytical and Bioanalytical Chemistry, 2011, 401 : 3355 - 3365
  • [35] Highly selective potentiometric determination of mercury(II) ions using 1-furan-2-yl-4-(4-nitrophenyl)-2-phenyl-5H-imidazole-3-oxide based membrane electrodes
    Mahajan, Rakesh Kumar
    Puri, Rajiv Kumar
    Marwaha, Alka
    Kaur, Inderpreet
    Mahajan, Mohinder Pal
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) : 237 - 243
  • [36] Flow injection potentiometry by a novel coated graphite electrode based on 5-(9-anthracenylmethyl)-5-aza-2,8-dithia[9],(2,9)-1,10-phenanthrolinophane for the selective determination of uranyl ions
    Shamsipur, Moitaba
    Mizani, Farhang
    Alizadeh, Kamal
    Mousavi, Mir Fazlollah
    Lippolis, Vito
    Garau, Alessandra
    Caltagirone, Claudia
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (01): : 300 - 309