Validity of Physical Activity Measures in Individuals After Total Knee Arthroplasty

被引:11
|
作者
Almeida, Gustavo J. [1 ]
Wert, David Vi. [1 ]
Brower, Kelly S. [2 ]
Piva, Sara R. [1 ]
机构
[1] Univ Pittsburgh, Dept Phys Therapy, Pittsburgh, PA USA
[2] Univ Pittsburgh, Sch Hlth & Rehabil Sci, Pittsburgh, PA USA
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2015年 / 96卷 / 03期
关键词
Accelerometry; Activities of daily living; Arthroplasty; replacement; knee; Energy metabolism; Reference standards; Rehabilitation; Validation studies; ESTIMATING ENERGY-EXPENDITURE; TEST-RETEST RELIABILITY; INDIRECT CALORIMETRY; ACTIVITY MONITORS; TRIAXIAL ACCELEROMETRY; MULTISENSOR ARMBAND; VALIDATION; OSTEOARTHRITIS; EXERCISE; WALKING;
D O I
10.1016/j.apmr.2014.10.009
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To determine the concurrent criterion-related validity of 2 activity monitors in comparison with the criterion method of indirect calorimetry in older adults after total knee arthroplasty (TKA). Design: Validation study. Setting: Subjects completed 9 increasingly demanding daily activities in a research laboratory; each activity was performed for 7 minutes, for a total of 80 minutes, while the activity monitors and criterion method were used concurrently. Participants: Subjects (N=21, 67% women) had a mean age +/- SD of 68 +/- 7 years and a body mass index of 29 +/- 4. Interventions: Not applicable. Main Outcome Measures: Energy expenditure (in kcal/min) measured by accelerometer-based and multisensor-based monitors and by a criterion method. Validity was assessed by the paired t test, intraclass correlation coefficient (ICC), and Bland-Altman plots comparing the measurements from the activity monitors with those of the criterion method. Results: Measurements from the accelerometer-based monitor were significantly lower than those of the criterion method across all walking and nonwalking activities. The underestimations ranged from 40% to 100%. The accelerometer-based monitor demonstrated small to moderate agreement compared with the criterion method (ICCs from 0 to .38). Measurements from the multisensor-based monitor were significantly lower than those of the criterion method during several nonwallcing activities; yet, the differences were minor (2%-19%). Measurements from the multisensor-based monitor during walking activities were not different compared with the criterion method. The multisensor-based monitor demonstrated moderate to excellent agreement with the criterion method (ICCs from .48 to .81). Conclusions: The multisensor-based monitor showed better criterion-related validity than the accelerometer-based monitor and should be considered as a tool to measure physical activity in individuals after TKA. (C) 2015 by the American Congress of Rehabilitation Medicine
引用
收藏
页码:524 / 531
页数:8
相关论文
共 50 条
  • [1] Adherence to the Dutch recommendation for physical activity: prior to and after primary total hip and knee arthroplasty
    Latijnhouwers, Daisy A. J. M.
    Hoogendoorn, Karolien G.
    Nelissen, Rob G. H. H.
    Putter, Hein
    Vlieland, Thea P. M. Vliet
    Gademan, Maaike G. J.
    DISABILITY AND REHABILITATION, 2024, 46 (13) : 2862 - 2870
  • [2] Physical activity and symmetry following total knee arthroplasty: Results of a pilot randomized trial
    Queen, Robin M.
    Arbeeva, Liubov
    Bracey, Daniel N.
    Hales, Derek
    Hill, Carla
    Huffman, Katie F.
    Schwartz, Todd A.
    Allen, Kelli D.
    OSTEOARTHRITIS AND CARTILAGE OPEN, 2024, 6 (04):
  • [3] Validity and reproducibility of the Physical Activity Scale for the Elderly (PASE) questionnaire for the measurement of the physical activity level in patients after total knee arthroplasty
    Bolszak, Sylvain
    Casartelli, Nicola C.
    Impellizzeri, Franco M.
    Maffiuletti, Nicola A.
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [4] Reliability and Validity of the Dutch Version of the International Physical Activity Questionnaire in Patients After Total Hip Arthroplasty or Total Knee Arthroplasty
    Blikman, Tim
    Stevens, Martin
    Bulstra, Sjoerd K.
    van den Akker-Scheek, Inge
    Reininga, Inge H. F.
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2013, 43 (09) : 650 - 659
  • [5] Reliability of Physical Activity Measures During Free-Living Activities in People After Total Knee Arthroplasty
    Almeida, Gustavo J.
    Irrgang, James J.
    Fitzgerald, G. Kelley
    Jakicic, John M.
    Piva, Sara R.
    PHYSICAL THERAPY, 2016, 96 (06): : 898 - 907
  • [6] Lower-limb force production in individuals after unilateral total knee arthroplasty
    Rossi, MD
    Hasson, S
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (08): : 1279 - 1284
  • [7] Does Physical Activity Increase After Total Hip or Knee Arthroplasty for Osteoarthritis? A Systematic Review
    Arnold, John B.
    Walters, Julie L.
    Ferrar, Katia E.
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2016, 46 (06) : 431 - 442
  • [8] Physical Function and Physical Activity in Obese Adults After Total Knee Arthroplasty
    Smith, Webb A.
    Zucker-Levin, Audrey
    Mihalko, William M.
    Williams, Michael
    Loftin, Mark
    Gurney, James G.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2017, 48 (02) : 117 - +
  • [9] Validity and reproducibility of the Physical Activity Scale for the Elderly (PASE) questionnaire for the measurement of the physical activity level in patients after total knee arthroplasty
    Sylvain Bolszak
    Nicola C Casartelli
    Franco M Impellizzeri
    Nicola A Maffiuletti
    BMC Musculoskeletal Disorders, 15
  • [10] Physical Performance Correlates with Self-Reported Physical Function and Quality of Life in Patients at 3 Months after Total Knee Arthroplasty
    Choi, Jun Hwan
    Kim, Bo Ryun
    Kim, Sang Rim
    Nam, Kwang Woo
    Lee, So Young
    Kim, Won Bin
    Kim, Youn Ji
    ANNALS OF GERIATRIC MEDICINE AND RESEARCH, 2020, 24 (02): : 99 - 106