Intact-protein trapping columns for proteomic analysis in capillary high-performance liquid chromatography

被引:7
作者
Guan, Xia [1 ]
Yan, Guoquan [1 ]
Gao, Mingxia [1 ]
Hong, Guangfeng [1 ]
Deng, Chunhui [1 ]
Zhang, Xiangmin [1 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Monolithic trapping column; Chromatography; Intact proteins; Sol-gel; MONOLITHIC SILICA COLUMNS; MASS-SPECTROMETRY; STATIONARY PHASES; CATION-EXCHANGE; ELECTROCHROMATOGRAPHY; SEPARATIONS; GEL; PRECONCENTRATION; POLYMER; PARTICLES;
D O I
10.1016/j.chroma.2010.08.051
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new type of monolithic trapping columns with high mechanical strength was prepared by thin-layer sol-gel coating method and applied to trapping intact proteins for on-line capillary liquid chromatography. Monolithic trapping columns were fabricated by entrapping C8 reversed-phase particles into the capillary columns through a sot-gel network, which was formed by hydrolysis and polycondensation of methyltriethoxysilane. Hundreds times of trapping/untrapping for intact proteins were carried out. The trapping columns showed long-term stability up to 300 bar. Recovery, loading capacity and reproducibility of trapping columns were evaluated using four proteins. The recovery of four protein mixtures for the C8 monolithic trapping columns was 99.3% on average. The loading capacity of 5 mm x 320 mu m i.d. C8 trapping columns for the protein mixtures was 30 mu g. Day-to-day relative standard deviation (RSD) values for recoveries of protein mixtures on the same C8 trapping column ranged from 2.34 to 5.87%, column-to-column RSD values were from 3.01 to 6.81%. The C8 trapping columns were used to trap normal mouse liver intact proteins in a capillary liquid chromatography system. Results demonstrated high efficiency of the monolithic trapping columns for trapping intact proteins for proteomic analysis in on-line capillary liquid chromatography system. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:6875 / 6881
页数:7
相关论文
共 38 条
  • [1] Sintered octadecylsilica as monolithic column packing in capillary electrochromatography and micro high-performance liquid chromatography
    Asiaie, R
    Huang, X
    Farnan, D
    Horváth, C
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 806 (02) : 251 - 263
  • [2] Silica particles encapsulated poly(styrene-divinylbenzene) monolithic stationary phases for μ-high performance liquid chromatography
    Bakry, R.
    Stoeggl, W. M.
    Hochleitner, E. O.
    Stecher, G.
    Huck, C. W.
    Bonn, G. K.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1132 (1-2) : 183 - 189
  • [3] Top-down identification and quantification of stable isotope labeled proteins from Aspergillus flavus using online nano-flow reversed-phase liquid chromatography coupled to a LTQ-FTICR mass spectrometer
    Collier, Timothy S.
    Hawkridge, Adam M.
    Georgianna, D. Ryan
    Payne, Gary A.
    Muddiman, David C.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (13) : 4994 - 5001
  • [4] Top-down approaches for measuring expression ratios of intact yeast proteins using Fourier transform mass spectrometry
    Du, Y
    Parks, BA
    Sohn, S
    Kwast, KE
    Kelleher, NL
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (03) : 686 - 694
  • [5] Preparation and characterization of monolithic porous capillary columns loaded with chromatographic particles
    Dulay, MT
    Kulkarni, RP
    Zare, RN
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 5103 - 5107
  • [6] Large-bore particle-entrapped monolithic precolumns prepared by a sol-gel method for on-line peptides trapping and preconcentration in multidimensional liquid chromatography system for proteome analysis
    Gu, X
    Wang, Y
    Zhang, XM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1072 (02) : 223 - 232
  • [7] Capillary array reversed-phase liquid chromatography-based multidimensional separation system coupled with MALDI-TOF-TOF-MS detection for high-throughput proteome analysis
    Gu, Xue
    Deng, Chunhui
    Yan, Guoquan
    Zhang, Xiangmin
    [J]. JOURNAL OF PROTEOME RESEARCH, 2006, 5 (11) : 3186 - 3196
  • [8] Monolithic columns in high-performance liquid chromatography
    Guiochon, Georges
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1168 (1-2) : 101 - 168
  • [9] Polymer-based monolithic microcolumns for hydrophobic interaction chromatography of proteins
    Hemström, P
    Nordborg, A
    Irgum, K
    Svec, F
    Fréchet, JMJ
    [J]. JOURNAL OF SEPARATION SCIENCE, 2006, 29 (01) : 25 - 32
  • [10] High-performance polymer-based monolithic capillary column
    Hosoya, Ken
    Hira, Natsuki
    Yamamoto, Katsuya
    Nishimura, Masaru
    Tanaka, Nobuo
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (16) : 5729 - 5735